Description
Middle Atlantic BGR Series 276 CFM Fan Top for BGR Series Racks
Designed to deliver exceptional thermal management for professional rack environments, the BGR-276FT-FC Fan Top is a precision cooling solution built to protect sensitive equipment and sustain peak performance. Four pre-mounted high-performance fans generate up to 276 CFM of airflow while maintaining a quiet footprint with a measured 35 dBA, making it suitable for control rooms, studios, data centers, and production environments where cooling must coexist with minimal noise. Specifically engineered for the BGR Series racks, this top integrates seamlessly into existing infrastructure, providing a robust, maintenance-friendly path to reliable cooling without clutter or complicated installation steps.
- High-capacity cooling for dense gear: Up to 276 CFM of airflow rapidly moves heat away from hot-spot equipment, helping prevent thermal throttling and ensuring consistent performance across servers, amplifiers, switchgear, and other heat-generating components.
- Quiet, professional operation: The four high-performance fans are engineered for low noise, delivering crisp cooling without overwhelming the room. At 35 dBA, the fan top supports comfortable conversation levels and undisturbed monitoring in studios and control rooms.
- Ready-to-use, four-fan configuration: Pre-mounted on the top unit, these fans simplify installation and reduce downtime. The integrated design minimizes vibration transfer and maintains stable operation in busy rack environments.
- Rugged, rack-ready construction: Built for the rigors of daily professional use, the BGR Series fan top features a durable top-mounted design that aligns precisely with BGR racks, ensuring a secure fit and long service life.
- Designed for effortless maintenance and compatibility: Tailored for BGR Series enclosures, this fan top integrates smoothly with existing rack systems and provides straightforward access for cleaning and routine service, preserving airflow performance over time.
Technical Details of Middle Atlantic BGR Series 276 CFM Fan Top for BGR Series Racks
- Airflow: Up to 276 CFM
- Noise level: 35 dBA
- Fans: Four pre-mounted high-performance fans
- Mounting: Top-mounted fan top designed for BGR Series Racks
- Model reference: BGR-276FT-FC
How to install Middle Atlantic BGR Series 276 CFM Fan Top for BGR Series Racks
- Power down and unplug all equipment in the rack to ensure safe installation.
- Prepare the BGR rack by clearing the top surface and confirming it is clean and free of debris that could affect mounting.
- Place the BGR-276FT-FC on the rack’s top, aligning the mounting holes with the rack’s top-mount points for a secure, flush fit.
- Secure the fan top using the appropriate rack mounting hardware, tightening evenly to minimize vibration and ensure a stable, vibration-free interface with the enclosure.
- Connect the unit to a suitable power source per your facility’s electrical standards, using the rack’s power distribution or an appropriate supply. Verify that all four fans spin up smoothly and evenly.
- Power on the rack and verify airflow through the enclosure, checking for proper intake and exhaust paths and confirming that there are no obstructions reducing performance.
Frequently asked questions
- What is the primary function of the BGR Series 276 CFM Fan Top? It provides high-capacity cooling for BGR Series racks, using four pre-mounted fans to deliver up to 276 CFM of airflow while maintaining a low noise profile.
- Is this fan top compatible with all BGR racks? It is designed specifically for Middle Atlantic BGR Series racks and should be used with compatible BGR enclosures. Always confirm compatibility with your exact rack model and depth before installation.
- How loud is the fan top in operation? Typical operating noise is around 35 dBA, which is suitable for professional environments where quiet operation supports monitoring, recording, and critical listening tasks.
- How do I install the fan top? Follow the installation steps: power down equipment, align and secure the top to the rack, connect power according to local codes, and verify airflow and clearance after powering up.
- What maintenance is required? Regularly inspect the intake and exhaust areas for dust buildup and clean as needed to preserve airflow. Periodic checks of mounting integrity and fan operation help prevent vibration or noise issues over time.