Description
Middle Atlantic Contact Controlled Rack Mounted Power Distribution Unit - 6 Outlet Control
The Middle Atlantic PDC-915R-6 is a practical, purpose-built rack mounted power distribution unit crafted for efficient power management in demanding rack environments. Designed for professional AV, IT, and broadcast installations, it combines rear distribution outlets with a front convenience outlet to deliver flexible access to power where you need it most. With six controlled outlets, this unit enables precise power sequencing and selective shutdown for critical equipment, helping protect sensitive gear from power disturbances and simplifying maintenance routines. Built to endure the rigors of busy rack rooms, the PDC-915R-6 provides a clean, organized power distribution solution that complements standard 19-inch racks, supporting tidy cabling and improved airflow across dense equipment stacks.
- Six controlled outlets for precise power management. The PDC-915R-6 offers six outlets that can be controlled as a group or individually (depending on configuration), allowing technicians to sequence startups, perform maintenance without disrupting essential devices, and isolate failures quickly to minimize downtime.
- Rear distribution outlets with a front convenience outlet. Rear outlets enable clean cable routing behind equipment cabinets, while the front outlet provides quick, on-rack access for a monitor, tester, or portable device, reducing clutter and the need for extension cords.
- Rack-ready 19-inch enclosure. Built to fit seamlessly into standard 19-inch racks, the unit employs a rugged metal chassis and standardized mounting points to ensure solid support and reliable operation in busy data centers, studios, and control rooms.
- Compact, space-saving design. The PDC-915R-6 condenses essential power control into a compact footprint, maximizing rack space without sacrificing accessibility, organization, or performance—ideal for dense rack deployments and modular systems.
- Simple installation and maintenance. With straightforward, front-panel control and clean rear cabling options, technicians can install, test, and service the unit quickly, keeping downtime to a minimum and ensuring consistent power distribution across critical equipment.
Technical Details of Middle Atlantic Contact Controlled Rack Mounted Power Distribution Unit - 6 Outlet Control
- Model: PDC-915R-6
- Outlet configuration: 6 controlled outlets; 1 front convenience outlet; rear distribution outlets
- Rack compatibility: 19-inch rack-mount enclosure for standard racks
- Enclosure: durable metal construction suited for professional environments
- Mounting and cabling: rear outlets support clean cabling runs; front outlet provides local access
how to install Middle Atlantic Contact Controlled Rack Mounted Power Distribution Unit - 6 Outlet Control
Before you begin, map out a clear plan for how you want to distribute power in your rack. Identify which devices require controlled power and which can rely on a constant supply, and decide which outlets will occupy the six controlled positions versus the front convenience outlet. This planning helps you optimize startup sequences, reduce downtime during maintenance, and protect sensitive equipment from power disturbances.
1) Prepare the rack space: Ensure your rack area is clean, ventilated, and free of obstructions. Verify that the mounting surface is level and able to support the PDC-915R-6’s weight and any attached cabling. If you use rack rails, align the unit with existing equipment for a uniform front panel height and accessible outlets.
2) Mount the PDC-915R-6: Align the enclosure with the rack rails and secure it using the appropriate screws at the top and bottom mounting points. Check that the unit sits firmly and does not flex when cables are connected. Proper mounting minimizes vibration and helps preserve connector integrity over time.
3) Connect the power input: Locate the PDU’s incoming power connection and connect it to the facility power source or to a suitable upstream power distribution point per your local electrical code. Ensure the input power rating aligns with the PDC-915R-6 specifications and does not exceed the circuit capacity. Use a properly rated power cord and avoid daisy-chaining through multiple PDUs wherever possible to maintain consistent performance.
4) Arrange outlets and cables: Plan device placement so that critical equipment sits on the six controlled outlets, while the front convenience outlet serves any device that requires local access. Route cables behind the rack using cable management arms or ties to keep the front area clear for airflow and service access. Label each outlet clearly to simplify future maintenance and prevent accidental disconnections during servicing.
5) Configure and test: If the PDC-915R-6 supports any control features beyond simple on/off switching, refer to the user manual to configure outlet control as needed. After powering on, test each outlet with appropriate test equipment or a known-good device to confirm correct operation. Verify that all rear and front outlets deliver power as expected and that the controlled outlets respond to your control scheme. Check for any heat buildup and ensure there is adequate ventilation around the unit. Finally, document the outlet assignments and control settings for future reference and maintenance planning.
6) Safety and compliance: Use proper personal protective equipment as required by your local electrical codes when wiring and commissioning the PDU. Ensure that total load drawn by all outlets remains within the device’s rated capacity and within the circuit’s limits. Periodically inspect cabling for wear or damage and replace any compromised components promptly. By following these steps, you’ll maximize reliability, simplify maintenance, and extend the life of your rack equipment.
Frequently asked questions
- Q: What is the Middle Atlantic PDC-915R-6? A: It is a contact controlled rack mounted power distribution unit designed for professional environments, featuring six controlled outlets and a front convenience outlet for flexible power access in standard 19-inch racks.
- Q: How many outlets does it have and how are they arranged? A: The unit includes six controlled outlets along with a single front convenience outlet, and there are rear distribution outlets to support tidy cable routing.
- Q: Can it fit in a standard 19-inch rack? A: Yes. The PDC-915R-6 is built as a rack-mount enclosure compatible with standard 19-inch racks used in data centers, studios, and control rooms.
- Q: What are the benefits of a six-outlet controlled PDU in a rack? A: Six controlled outlets enable selective power sequencing and targeted outage protection for critical equipment, while the front outlet provides quick local access for auxiliary devices, helping keep cables organized and improving maintenance efficiency.
- Q: How should I install this PDU? A: Install in a secured 19-inch rack, connect the input power to a suitable supply, route and label cables to the rear outlets and front outlet, configure control settings as needed, and test each outlet to ensure proper operation and airflow within the rack.