Middle Atlantic CWR Series 18RU Wall Mounted Rack - Swinging Wall Mounted Rack - 17in Depth
The CWR-18-17PD is a purpose-built wall-mounted rack system from Middle Atlantic designed for structured cabling environments where floor space is at a premium and reliable, orderly equipment mounting is essential. With 18U of vertical rack space and a compact 17-inch depth, this swinging wall rack makes it possible to consolidate servers, switches, patch panels, power condition modules, and AV gear in tight rooms, data closets, control rooms, or broadcast setups. The result is a clean, professional installation that balances accessibility, airflow, and security, while preserving precious room dimensions for other critical infrastructure. Built to endure the rigors of daily use in professional installations, the CWR-18-17PD offers a durable solution that scales with your evolving IT, AV, and network needs.
Designed for practical, long-term reliability, the CWR-18-17PD features welded steel construction and a robust, powder-coated finish that resists impact, corrosion, and dust. The swinging wall mount design enables effortless, tool-free access to rear cabling and equipment, reducing maintenance time and downtime during reconfigurations. The combination of a secure front door, ventilated panels, and standard 19-inch rails ensures compatibility with a wide range of equipment from compact AV processors to compact network switches and patch panels. Whether you’re building out a small data closet, a professional recording studio, or a high-demand control room, this rack provides a professional-grade platform that keeps equipment organized, protected, and easy to service.
As a hallmark of Middle Atlantic quality, the CWR-18-17PD emphasizes thoughtful cable management and airflow. The rack is designed to minimize heat buildup around stacked devices while keeping cables tidy and accessible. This translates into improved reliability, easier troubleshooting, and a more polished, scalable setup. The 18U capacity accommodates a broad spectrum of devices in a single, integrated enclosure, reducing clutter and the need for multiple cabinets or stands. With its secure locking mechanism, it also helps protect sensitive equipment from tampering or accidental interference—an important consideration in shared environments and production facilities. In short, the CWR-18-17PD delivers a sophisticated, space-efficient mounting solution that combines strength, flexibility, and professional-grade features in one compact package.
- Space-saving wall-mounted design: The 18U configuration maximizes vertical mounting space while keeping equipment within easy reach. Its 17-inch depth is engineered to fit tight rooms, control centers, and broadcast suites where floor-standing racks would feel bulky. The swinging mechanism allows the front door to stay closed during installation and maintenance, while the entire rack swings out for full rear access. This reduces the need to clear large walkways or move equipment mid-project, enabling faster deployments and simpler upgrades. With careful cable routing and dedicated cable management features, you can maintain clean, organized runs from patch panels to switches and power conditioners without compromising airflow or accessibility. This design is particularly advantageous in environments with limited room width, such as data closets behind desks, control rooms with streaming gear, or small studio spaces where every inch matters.
- Locking front door for security and dust protection: The front door includes a reliable locking mechanism to keep critical devices shielded from dust, tampering, or accidental access during busy production days or in shared facilities. The locking feature provides peace of mind in environments where equipment must stay secure while still offering rapid, tool-free servicing. The swing-out design allows technicians to reach rear cables and devices without removing equipment, making routine maintenance, firmware updates, and reconfigurations faster and safer. In practice, this combination of security and accessibility translates to fewer service interruptions and a more efficient workflow for IT, AV, and broadcast teams alike.
- Rugged welded steel construction with durable finish: Built to withstand demanding professional environments, the CWR-18-17PD uses welded steel construction for enhanced rigidity and longevity. The black powder-coated finish resists scratches, scuffs, and everyday wear, preserving the rack’s pristine appearance even after years of use in busy facilities. This robust build ensures that mounted equipment remains stable during operation and when the rack is swung open or closed, reducing the risk of misalignment or equipment damage. The combination of strength and a modern, professional finish makes the CWR-18-17PD a dependable centerpiece for any room where performance and presentation matter.
- Standard 19-inch rails and flexible layout for broad compatibility: The rack incorporates standard 19-inch mounting rails, supporting a wide range of devices from small DSPs to compact switches, patch panels, and compact amplifiers. Rails are adjustable to accommodate different equipment heights and configurations, giving you flexibility to optimize space, serviceability, and airflow. Removable side panels and accessible interior channels support clean, efficient cable management, enabling neat, compliant installations that satisfy both performance and aesthetic expectations. This standard compatibility ensures you don’t have to compromise on gear choice or future upgrades, making the CWR-18-17PD a scalable solution for evolving networks and AV installations.
- Efficient cooling and organized cable management: Thoughtful ventilation and cable routing capabilities help maintain stable operating temperatures and reduce thermal hotspots. Perforated panels, vented sides, and dedicated cable-management pathways keep airflow unobstructed around dense equipment stacks. Proper airflow reduces fan noise, extends component life, and minimizes the risk of thermal throttling in high-demand setups. In practice, this means more reliable performance during long sessions, streams, or broadcast runs, and a cleaner, easier-to-maintain rack environment overall.
Technical Details of Middle Atlantic CWR-18-17PD
- Model: CWR-18-17PD
- Rack Units: 18U
- Depth: 17 in
- Height (approx.): 31.5 in
- Width (external): 24 in
- Material: Welded steel
- Finish: Black powder coat
- Weight Capacity: Up to 200 lb (90 kg)
- Rails: Standard 19" mounting rails (top and bottom)
- Doors: Locking swinging front door
- Ventilation: Perforated front panel with rear ventilation
- Mounting: Wall-mounted swing-out rack with mounting studs for solid backing
- Certifications: UL-listed, RoHS compliant
- Included accessories: Removable side panels, integrated cable management features
how to install Middle Atlantic CWR-18-17PD
- Step 1: Plan your layout. Identify wall studs or a solid backing capable of supporting the full weight of the rack plus equipment. Use a stud finder to confirm stud locations, and mark a level mounting line that will align with the rack’s back mounting points.
- Step 2: Prepare the mounting surface. If mounting to studs, select appropriate heavy-duty screws or lag bolts rated for the wall material. For masonry walls, use concrete anchors or wall brackets designed for rack installations. Ensure you have all required hardware before beginning assembly.
- Step 3: Attach the swing-out frame to the wall. With help, lift the rack into position and secure the wall-mounted frame to the studs or backing through the predrilled mounting holes. Verify levelness and tighten hardware to the manufacturer’s torque recommendations. A secure base is essential for safe operation of the swing-out mechanism and for supporting the weight of loaded equipment.
- Step 4: Install the rack rails and accessories. Mount the standard 19" rails to the sides at the desired heights, and adjust for the equipment you plan to install. Attach removable side panels and any cable-management features included with the rack to establish clean, accessible pathways for power and data cables.
- Step 5: Load and arrange equipment. Begin with heavier devices toward the bottom to lower center of gravity and improve stability. Leave ample headroom for cooling and service access, then route cables through the management guides to minimize tangling and obstruction.
- Step 6: Close the door and test operation. After loading the devices, swing the rack back into its mounted position, engage the locking door, and verify that the swing mechanism opens smoothly without interference. Perform a quick check of cable clearances, ventilation, and weight distribution to ensure safe, reliable operation.
Frequently asked questions
- Q: What equipment can fit in the CWR-18-17PD? A: The rack supports standard 19" devices up to 18U of height. Its 17" depth accommodates a wide range of AV processors, switches, patch panels, power conditioners, and compact servers while leaving room for cable management and cooling. The exact compatibility will depend on the depth and clearance of individual devices, but the 18U capacity provides substantial versatility for small to mid-size configurations.
- Q: Does the rack include mounting hardware? A: The CWR-18-17PD ships with the essential components for wall mounting, including rails and side panels. Some installations may require additional wall anchors or hardware appropriate to the wall type and building codes. Always verify hardware compatibility with your wall construction before installation.
- Q: Is the rack lockable? A: Yes, the front door is locking to protect equipment from dust, tampering, or unauthorized access. This is especially valuable in shared spaces or production environments where security is a concern.
- Q: How do I manage cables inside the rack? A: The CWR-18-17PD includes integrated cable-management features and removable side panels to help organize and route cables efficiently. Plan your cable paths in advance and utilize the rails’ mounting points and guides to keep data, power, and AV cabling neatly separated and easy to service.
- Q: What about airflow and cooling? A: The rack is designed with ventilation in mind, featuring perforated front panels and ventilated sides to promote airflow around heat-generating equipment. Proper placement away from sources of heat and adequate intake/outtake clearance will further enhance cooling performance and equipment longevity.
Customer reviews