Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan

Middle AtlanticSKU: 5541677

Price:
Sale price$89.10

Description

Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan

Engineered to protect high-value electronics in racks and open shelving, the Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan delivers targeted heat removal exactly where it matters. This thermostatically controlled component cooler is designed to sit directly on the vents of heat-generating equipment, pulling heat away from boards, power supplies, and other critical components before it has a chance to throttle performance. By integrating cooling at the source, it reduces ambient rack temperatures, extends equipment life, and helps maintain consistent performance in environments where space is tight and airflow is a premium. Whether you’re outfitting a data rack, A/V rack, or broadcast room, this compact cooling solution is built to operate quietly, efficiently, and reliably so you can focus on your work without distraction or concern about overheating.

  • The ICOMP-COOL is thermostatically controlled, meaning cooling kicks in automatically when the internal temperature rises and shuts off when it returns to safe levels. This dynamic response minimizes energy usage and wear on the system while maintaining a stable, temperature-controlled environment for critical components. By reacting to actual heat, it avoids unnecessary cooling cycles and helps keep operating costs down in busy server rooms and editing suites.
  • Designed to sit directly on top of vents from heat-generating equipment, the component cooler targets heat right at the source. This placement optimizes airflow where it matters most, helping to prevent hotspots on circuit boards, power supplies, and other sensitive hardware. The result is more predictable thermal performance across racks and open shelving configurations, even when ambient room temperature fluctuates.
  • Optimized for open shelving and rack installations, the ICOMP-COOL integrates seamlessly with standard equipment layouts. Its compact footprint fits in tight spaces between devices and behind equipment shelves, while its orientation supports natural air movement through the rack. This makes it a versatile cooling companion for data centers, broadcast studios, control rooms, and home theater racks alike.
  • Quiet operation is a cornerstone of the design, delivering robust airflow without introducing disruptive noise into environments where focus and audio quality matter. The ICOMP-COOL provides dependable cooling with minimal acoustic intrusion, allowing you to maintain concentration in editing suites, conference rooms, and server closets without sacrificing performance.
  • Reliable performance with minimal maintenance. The cooler is built to run continuously in demanding environments, reducing the likelihood of thermal throttling and extending the lifespan of heat-sensitive components. The straightforward design emphasizes durability, easy serviceability, and long-term value for systems that rely on steady, predictable cooling over time.

Technical Details of Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan

  • Thermostatically controlled cooling delivers automatic activation when heat is detected, ensuring heat removal happens exactly when needed and conserving energy when temperatures are within safe ranges.
  • Precise placement on top of the vents of heat-generating equipment allows direct extraction of rising hot air, improving overall thermal efficiency for nearby components.
  • Automatic on/off operation aligns with varying workloads, helping to prevent thermal hotspots without requiring manual intervention or constant monitoring.
  • Optimized for integration with open shelving and standard rack configurations, providing versatile cooling across multiple equipment setups without requiring custom adapters.
  • Compact, space-saving design minimizes footprint while preserving clearance for cable management and adjacent devices in crowded racks.
  • Low-noise performance supports quiet environments such as studios, edit suites, control rooms, and data centers where acoustic comfort matters as much as cooling.
  • Durable construction tailored for rack environments, delivering consistent airflow and reliable operation under steady-duty conditions.
  • Energy-efficient heat removal reduces strain on central cooling systems, contributing to lower overall energy use and improved uptime for critical equipment.

How to install Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan

  • Power down and unplug all equipment before starting installation to ensure safety and prevent data loss or sensor interference during setup. Confirm that you have a clear working area and enough space for airflow around the cooler.
  • Place the ICOMP-COOL directly on top of the vents of the heat-generating unit. Align the cooler so that its intake and exhaust directions correspond to the natural airflow path of the rack or shelf, maximizing heat capture from the device below.
  • Secure the cooler if required by your specific rack or equipment configuration. Use any provided mounting hardware or compatible fasteners to ensure the cooler remains stable during operation and does not shift with vibration or airflow.
  • Reconnect power to the cooling unit and power on the equipment. Allow the thermostat to calibrate as the system begins to reach operating temperature, and verify that the cooler activates automatically when heat levels rise.
  • Monitor the airflow and thermal response of adjacent components. If hotspots persist, reevaluate placement to ensure unobstructed intake or exhaust paths and consider rearranging cables to avoid blocked vents or restricted airflow.
  • Perform routine maintenance by inspecting the grille for dust and debris and cleaning as needed. Regular cleaning helps sustain efficient airflow and maintains consistent cooling performance over time.

Frequently asked questions

  • Q: What is the primary purpose of the Middle Atlantic Quiet-Cool ICOMP-COOL Cooling Fan? A: It provides targeted, thermostatically controlled cooling directly at heat-generating components in racks or open shelving, helping prevent overheating and maintain stable performance.
  • Q: How does the thermostat control work? A: The fan automatically turns on when the detected temperature exceeds a preset threshold and turns off once the temperature returns to a safe level, reducing unnecessary energy use and wear.
  • Q: Where should I install the cooling fan for best results? A: Place the cooler directly on top of the vents of the hot equipment, ensuring alignment with the rack’s airflow path and avoiding obstructions like cables or doors that could impede intake or exhaust.
  • Q: Is this fan suitable for all rack sizes and configurations? A: It is optimized for open shelving and standard rack setups, offering flexibility for most AV, data, broadcast, and server environments. Always verify clearance and airflow before installation.
  • Q: What maintenance is required to keep the ICOMP-COOL functioning well? A: Periodic inspection of the grille for dust buildup, gentle cleaning as needed, and ensuring that airflow paths remain unobstructed will help sustain peak cooling performance over time.