Description
Middle Atlantic Remote Wall Plate Keyswitch
Elevate your AV control with the Middle Atlantic Remote Wall Plate Keyswitch, a compact, purpose-built remote switch that initiates remote up/down sequencing for complex audiovisual systems. This device is engineered to work hand-in-hand with the USC-6R Universal Sequencing Controller, delivering a reliable, wall-mounted interface that simplifies critical power sequences while protecting delicate equipment. The remote keyswitch is designed for clean, professional installations, featuring a Decora-style faceplate that fits neatly into standard openings and matches Middle Atlantic’s robust mounting systems, cable management, and rack infrastructure. With secure RJ-45 connectivity and a terminal block, setup is straightforward, durable, and scalable for projects ranging from executive boardrooms to high-end home theaters and classroom environments. Depending on the model, status LED indicators provide real-time feedback, enabling operators to confirm when a sequence has been commanded, when it is in progress, and when it has completed. The combination of intuitive operation, sturdy construction, and seamless integration with Middle Atlantic sequencing solutions makes the Remote Wall Plate Keyswitch an essential tool for professionals who demand precision, safety, and reliability in power management. Whether you’re coordinating multiple displays, projectors, amplifiers, or other AV gear, this keyswitch gives you an accessible, hard-wired control point that reduces inrush energy, minimizes risk during startup, and keeps your control room uncluttered. In short, it’s a practical, durable, and scalable solution for centralized sequencing control that enhances performance, protection, and workflow efficiency across a wide range of applications.
- Remote Up/Down Sequencing Initiation: Trigger the exact startup or shutdown sequence for connected equipment via the USC-6R controller, allowing orderly power-on and power-off of displays, projectors, receivers, and other gear to prevent inrush surges and boot conflicts.
- Status LED Indicators (where equipped): Some models include status LEDs that provide at-a-glance confirmation of command issuance, sequence progress, and completion, simplifying monitoring and troubleshooting in busy AV environments.
- Easy, Clean Connectivity: Connects to the USC-6R Universal Sequencing Controller through a simple RJ-45 jack and a secure terminal block, delivering a tidy, reliable wiring solution that supports clean wall installations and easy maintenance.
- Decora Mount Aesthetics for Professional Installations: The Decora-style faceplate integrates seamlessly with standard wall boxes and Middle Atlantic’s mounting rails, ensuring a discreet, professional appearance in conference rooms, classrooms, and home theaters alike.
- Durable, Enterprise-Grade Build: Built for frequent use in demanding environments, the remote keyswitch provides long-term reliability and consistent performance, coordinating with the USC-6R to protect sensitive equipment during power transitions.
Technical Details of Middle Atlantic Remote Wall Plate Keyswitch
- Interface: RJ-45 jack to USC-6R Universal Sequencing Controller
- Wiring: Terminal block connection for secure, low-voltage wiring to control circuits
- Mounting: Decora-style wall plate compatible with Middle Atlantic mounting rails and standard Decora openings
- Function: Remote initiation of up/down sequencing to coordinate AV power sequences
- Indicators: Status LEDs on select models to convey command status and sequence progress
- Power: Powered through the connection to the USC-6R controller; no separate power supply required in standard configurations
How to install Middle Atlantic Remote Wall Plate Keyswitch
- Preparation: Verify that your USC-6R Universal Sequencing Controller is properly installed and that you have a compatible Decora wall box for the installation location.
- Mounting the faceplate: Remove the existing wall plate if present, open the Decora box, and secure the Middle Atlantic Decora wall plate in place using the supplied mounting screws. Ensure the opening aligns with your conduit or cable routing for clean wiring.
- Wiring the terminal block: Connect the control wiring from the wall location to the terminal block on the keyswitch according to your system’s control diagram. Maintain secure, low-resistance connections and clean routing to prevent interference or accidental disconnections.
- RJ-45 connection to USC-6R: Plug the RJ-45 connector from the wall plate keyswitch into the corresponding port on the USC-6R controller. Confirm a snug, locked connection to ensure reliable data and trigger transmission.
- Final checks and testing: With the system powered, verify that the keyswitch initiates the desired up/down sequence through the USC-6R. Confirm LED indicators (if equipped) reflect the correct status, and test multiple cycles to ensure consistent performance.
- Now secure the faceplate: Once all connections are verified, reattach the front faceplate, ensuring the edges are flush and the device presents a clean, professional appearance.
Frequently asked questions
- Q: What is the primary purpose of the Middle Atlantic Remote Wall Plate Keyswitch?
- A: It provides a remote, wall-mounted interface to initiate remote up/down sequencing for AV equipment via the USC-6R controller, enabling coordinated power management without needing to operate individual devices at the rack.
- Q: How does it connect to the control system?
- A: The device uses an RJ-45 jack to connect to the USC-6R Universal Sequencing Controller and includes a terminal block for secure wiring to the control circuit.
- Q: Are LEDs available on all models?
- A: Status LED indicators are available on select models to offer visual feedback on command status, sequencing progress, and completion.
- Q: Do I need a separate power supply for the keyswitch?
- A: No; it is powered through the connection to the USC-6R controller in standard configurations.
- Q: Is this compatible with other controllers or only with USC-6R?
- A: The keyswitch is designed to work with the USC-6R Universal Sequencing Controller. For installations using other controllers, consult product compatibility documentation or contact Middle Atlantic support for guidance.
- Q: Can I install this in a standard Decora opening?
- A: Yes, the Decora-style wall plate is designed to fit standard Decora openings and is compatible with Middle Atlantic’s mounting systems for a clean, professional look.
Customer reviews
Showing - Of Reviews