Description
Middle Atlantic RIB-2-MRK-26 Riser Base
Designed for dedicated data centers, control rooms, and advanced AV installations, the Middle Atlantic RIB-2-MRK-26 Riser Base is a critical component of the Raised Floor Enclosure System. This 2-1/2" high riser base is engineered to streamline installation workflows by enabling field rough-in procedures before racks and enclosures arrive on site. It also doubles as a practical lower cable chase, allowing technicians to pass and organize cables between racks in multi-bay configurations with minimal disruption to the installation flow. By combining robust support with intelligent cable management, this riser base helps professionals save time, reduce labor, and achieve a cleaner, more efficient rack room environment from the first day of commissioning.
- 2-1/2" high riser bases provide a stable platform that supports early field rough-in work, allowing technicians to route and organize connections before the main equipment arrives. This setup minimizes backtracking and keeps the job on schedule, even when lead times for racks and enclosures stretch a project timeline.
- Acts as a lower cable chase for passing cables between racks in multi-bay applications. The design helps maintain clean pathways, improve airflow, and simplify future upgrades or reconfigurations by keeping cables neatly separated from floor traffic and equipment mounting surfaces.
- Part of the Raised Floor Enclosure System, the RIB-2-MRK-26 integrates seamlessly with Middle Atlantic components to deliver a cohesive, professional installation. Its compatibility supports streamlined procurement and reduces the guesswork involved in matching disparate pieces from different vendors.
- Built with durability in mind for demanding environments, ensuring long-term reliability in control rooms, data centers, and broadcast facilities. The riser base is designed to withstand typical installation stresses, providing steady support and reducing the risk of misalignment as cables and components are added over time.
- Enhances installation workflows by enabling quicker readiness for rack delivery. By letting rough-in work proceed ahead of the racks, technicians can accelerate commissioning, minimize on-site downtime, and improve overall project efficiency without compromising safety or cable integrity.
Technical Details of Middle Atlantic RIB-2-MRK-26 Riser Base
- 2-1/2" (approximately 63.5 mm) riser height designed to align with the Raised Floor Enclosure System footprint
- Part of the Raised Floor Enclosure System for enhanced compatibility with Middle Atlantic racks and enclosures
- Ideal for field rough-in procedures prior to rack delivery and installation
- Serves as a lower cable management channel to support multi-bay cabling strategies
- Durable construction optimized for professional AV, data center, and control room environments
How to install Middle Atlantic RIB-2-MRK-26 Riser Base
To maximize the benefits of the RIB-2-MRK-26, start with a quick assessment of your bay layout and floor plan. Ensure the raised floor grid is accessible and free from debris, and identify the most efficient pathways for cables that will run beneath and between racks in the anticipated configuration. Position the riser bases so that their alignment corresponds with the rack footprints and the intended cable routes. If your installation requires multiple bays, place the riser bases at intervals that align with the grid and the centerlines of the racks to maintain uniform cable channels and predictable working space. After positioning, run the rough-in cables through the lower channels and secure them as needed before the racks are installed. Finally, verify that all cables maintain proper bend radii and are organized in a way that supports eventual rack mounting, airflow, and easy access for maintenance or future upgrades.
Step 1: Prepare the installation area by inspecting the raised floor grid and confirming bay alignment with the intended rack layout. Clear debris and ensure the floor tiles are seated correctly to avoid any misalignment during base placement.
Step 2: Place the RIB-2-MRK-26 riser bases in their designated positions, ensuring consistency with the bay spacing and the planned cable routes. Check that each base sits level and stable to provide a reliable foundation for rough-in work and subsequent equipment installation.
Step 3: Begin field rough-in work by routing cables beneath the raised floor and through the bottom channels of the riser bases. Maintain clean, organized pathways and keep power and data cables separated as required by your facility's code and best practices.
Step 4: After rough-in, review cable routes for bend radii, potential interference with future rack components, and ease of access for service or reconfiguration. Make any necessary adjustments before racks are brought in for final installation.
Step 5: Install racks and enclosures, ensuring the riser bases remain properly aligned and seated. Recheck cable channels for neatness and airflow, and secure any remaining cables or tie-downs as dictated by your project standards.
Step 6: Perform a final walk-through to confirm that all components are properly integrated, cables are organized, and the system meets your performance criteria for signal integrity, cooling, and accessibility. Document the layout for future maintenance and upgrades.
Frequently asked questions
- Q: What is the purpose of the RIB-2-MRK-26 Riser Base?
- A: The RIB-2-MRK-26 serves as a 2-1/2" high riser base within the Middle Atlantic Raised Floor Enclosure System. It enables field rough-in procedures before racks arrive and functions as a lower cable chase to simplify cabling between racks in multi-bay configurations, delivering time savings and improved cable management.
- Q: Can the riser base be used in multi-bay installations?
- A: Yes. The design supports multi-bay configurations by providing a continuous, organized pathway for cables between adjacent racks, helping maintain a tidy infrastructure and reducing installation complexity in larger systems.
- Q: How does this product affect installation time?
- A: By allowing rough-in work to occur before the arrival of racks and enclosures, the riser base shortens on-site labor and accelerates commissioning. Technicians can route and secure cables early, minimizing delays and rework later in the project.
- Q: Is the RIB-2-MRK-26 compatible with other Middle Atlantic components?
- A: The riser base is designed to integrate with the Raised Floor Enclosure System and is compatible with Middle Atlantic racks and enclosures, providing a cohesive platform across the installation for better fit and ease of maintenance.
- Q: What environments is the riser base suitable for?
- A: It is intended for professional AV, data center, and control room environments where floor-level cabling, cable management, and modular deployment are priorities. Its durable concept supports everyday use in demanding installations.