Description
Minuteman Battery Module
The Minuteman Battery Module is a high-reliability, lead-acid UPS battery designed to maximize uptime and simplify maintenance. Engineered for versatility, this hot-swappable module fits a wide range of uninterruptible power supplies, delivering dependable runtime while reducing downtime during battery swaps. With a focus on safety and efficiency, the Minuteman Battery Module combines proven lead-acid chemistry with low self-discharge, allowing flexible installation in spaces that may be constrained or awkward to access. Its long life, practical recharge time, and mounting versatility make it a practical upgrade or replacement battery for mission-critical environments such as data centers, network closets, and industrial settings.
- Hot-Swappable Design for Uptime — Swap the battery module without powering down the UPS, keeping critical systems online and maintenance windows short.
- Lead-Acid Reliability — Trusted SLA lead-acid chemistry delivers consistent performance, robust temperature tolerance, and dependable backup power when it matters most.
- Extended Battery Life — A 3-year minimum life and up to a 5-year maximum life provide long-term value and predictable maintenance planning for your infrastructure.
- Efficient Recharge — Recharge time of 8 hours helps restore essential backup capacity quickly after discharge, supporting rapid readiness for any power event.
- Versatile Mounting with Low Self-Discharge — Mount in virtually any position to fit your UPS cabinet and installation space, while low self-discharge preserves battery readiness during storage.
Technical Details of Minuteman Battery Module
- Battery Type: Lead Acid
- Chemistry: Sealed Lead-Acid (SLA) with low self-discharge
- Runtime at half-load: 0.08 hours
- Runtime at full-load: 0.28 hours
- Recharge Time: 8 hours
- Hot Swappable: Yes
- Mounting Orientation: Virtually any position
- Service Life: 3 years minimum, up to 5 years maximum
- Fitment: Offers a reasonable compatibility window with a broad range of UPS models
How to install Minuteman Battery Module
- Power down the UPS according to the manufacturer’s guidelines and disconnect from the mains to ensure safe handling.
- Open the battery compartment and identify the hot-swappable bay designated for the Minuteman Battery Module.
- Align the module with the bay connectors and slide it into place until it locks securely. Ensure all connectors are fully seated.
- Reconnect any cables, re-secure the panel, and confirm there is no strain on wires or misalignment of the module.
- Power on the UPS and run a brief self-test to verify battery recognition, proper voltage, and expected runtime indicators.
Frequently asked questions
- Q: Is the Minuteman Battery Module hot-swappable?
- A: Yes. The hot-swappable design allows you to replace the battery module without powering down the UPS, minimizing downtime and keeping critical loads protected.
- Q: What is the runtime at different loads?
- A: The module provides approximately 0.08 hours of runtime at half-load and about 0.28 hours at full-load, enabling you to estimate backup time for essential devices during an outage.
- Q: How long does it take to recharge?
- A: Recharge time is approximately 8 hours to return to full backup capacity after discharge, depending on the UPS charging profile and usage conditions.
- Q: What is the battery life expectancy?
- A: The Minuteman Battery Module is designed with a minimum life of 3 years and a maximum life of up to 5 years, offering a long-term maintenance window for business continuity planning.
- Q: Can this battery be mounted in any orientation?
- A: Yes. It is designed for mounting in virtually any position, providing installation flexibility in tight spaces or non-standard cabinets, while maintaining safety and performance.