Description
Minuteman Endeavor ED1000RMT2U 1000VA Rack/Wall/Tower UPS
The Minuteman Endeavor ED1000RMT2U is a premium true sine wave online UPS designed to protect critical equipment in a variety of environments—from compact data closets to expansive server rooms. With a robust 1000VA / 800W capacity, this versatile unit delivers reliable backup power for servers, networking gear, storage devices, and sensitive electronics, ensuring graceful shutdowns, data integrity, and reduced downtime during outages. Built to support 208V systems and featuring a strong 0.8 power factor, the ED1000RMT2U maximizes usable power while maintaining energy efficiency. Its flexibility shines through in its mounting options—rack, wall, and tower configurations—making it a smart fit for data centers, IT closets, labs, or home offices where space is at a premium. The Endeavor Series is engineered to handle the demanding power needs of modern IT environments, and the ED1000RMT2U continues that tradition with reliable performance, scalable runtimes, and easy installation in a variety of layouts. Four on-battery battery-backed outlets provide essential protection for critical equipment, and the capability for extended runtime with external battery modules adds a layer of resilience for longer outages or planned maintenance windows.
- Versatile mounting and compact design: This UPS can be installed as a rack-mounted unit, wall-mounted, or configured as a tower, enabling flexible placement in data centers, network closets, labs, or office spaces while preserving valuable floor space.
- True sine wave online protection: The ED1000RMT2U uses online, double-conversion topology to deliver a clean, continuous true sine wave output. This minimizes voltage distortions, reduces electrical noise, and safeguards sensitive equipment from input fluctuations, drops, and outages.
- Strong electrical specifications for professional environments: With 208V output, a high 0.8 power factor, and a capacity of 1000VA / 800W, it efficiently supplies critical devices while leaving room for additional hardware or peripherals in clustered IT setups.
- Battery-backed outlets for critical loads: Four (4) 6-15R outlets are powered by the internal battery during an outage, allowing you to run essential servers, switches, and storage devices long enough to complete backups and orderly shutdowns, preserving data and reducing risk.
- Extended runtime and scalability: The system is designed for extended runtimes and can be paired with external battery modules or additional power protection assets to extend backup time beyond the standard four minutes at full load and roughly thirteen minutes at half load, providing a buffer for long outages and maintenance windows without compromising workloads.
Technical Details of Minuteman Endeavor ED1000RMT2U 1000VA Rack/Wall/Tower UPS
- Model: Minuteman Endeavor ED1000RMT2U
- Topology: Online / double-conversion true sine wave UPS
- Capacity: 1000 VA / 800 W
- Output voltage: 208V
- Power factor: 0.8
- Outlets (on-battery): (4) 6-15R
- Mounting options: Rack, wall, and tower compatible
- Runtime (typical): ~4 minutes at full load (800 W); ~13 minutes at half load
- Extended runtime: Capable with external battery modules
- Intended use: Protects servers, networking gear, storage, and other sensitive electronics in IT environments
- Protection features: True sine wave output, automatic voltage regulation, surge protection, and battery-backed outlets for critical devices
How to install Minuteman Endeavor ED1000RMT2U
Installing the ED1000RMT2U is straightforward in spaces designed for IT infrastructure. Follow these guidelines to ensure safe and stable operation:
- Choose the installation location: Select a well-ventilated area with adequate clearance for cooling and cable management. Ensure the space remains free of dust and moisture and complies with local electrical codes.
- Decide mounting configuration: Determine whether you will mount the unit in a rack, attach it to a wall, or position it as a tower. Use the appropriate hardware supplied with the UPS to secure the unit firmly and level.
- Connect loads and outlets: Identify critical equipment that should stay powered during an outage and plug them into the four on-battery 6-15R outlets. Avoid overloading the UPS beyond its 800W / 1000VA rating.
- Electrical connections and power: Connect the UPS to a dedicated circuit per applicable electrical codes. The ED1000RMT2U is designed for 208V operation; ensure compatibility with your facility’s distribution panels and prevent daisy-chaining of devices beyond the UPS’s capacity.
- Battery installation and initial charging: If the unit ships with pre-installed batteries, place the UPS on in a supported position and allow the internal battery to reach full charge before connecting critical loads. If batteries are user-serviceable or expandable, follow the manual precisely for safe handling and configuration of external battery modules to extend runtime.
Frequently asked questions
-
Q: What is the runtime at full load?
A: Approximately 4 minutes at 800 W. This runtime can be extended by adding external battery modules or by reducing load where feasible, enabling more time for clean shutdowns or data backups. -
Q: Does the ED1000RMT2U provide true sine wave output?
A: Yes. It delivers true sine wave output through online double-conversion, ensuring compatibility with sensitive servers, storage, and networking equipment even during fluctuating input conditions. -
Q: Can it be mounted in a rack, on a wall, or as a tower?
A: Yes. The design supports rack, wall, and tower configurations to fit a wide range of spaces—from data centers to home labs. -
Q: How many outlets are battery-backed?
A: Four (4) 6-15R outlets are on-battery, providing protected power to critical devices during an outage. -
Q: Is the unit suitable for 208V electrical systems?
A: Yes. The ED1000RMT2U is specified for 208V operation, aligning with professional IT environments and equipment designed for higher voltage distribution.