Description
Minuteman Endeavor ED1000RTXL2U 1000VA UPS
In an era where systems stay online around the clock, downtime is not an option. The Minuteman Endeavor ED1000RTXL2U is an on-line, LCD-equipped uninterruptible power supply designed to protect critical applications with unwavering reliability. Built for today’s demanding networks, servers, and telecom equipment, this 1000VA UPS delivers a clean, continuous sine-wave output, even in the face of power disturbances, brownouts, and outages. Its flexible 2U form factor supports tower, rack, and wall-mount installations, making it a versatile solution for data centers, IT rooms, executive offices, and remote locations. With an intuitive LCD interface, hot-swappable batteries, and robust protection features, the Endeavor ED1000RTXL2U keeps your equipment safe, your data secure, and your uptime measurable.
- Versatile, space-saving design: 2U form factor that can be deployed as a tower, rack, or wall-mount unit to fit data centers, server rooms, and office environments with ease.
- Online double-conversion power: Pure, continuous sine-wave output with near-zero transfer time to protect sensitive equipment from voltage sags, surges, and interruptions.
- Front-panel LCD with real-time monitoring: The Endeavor LCD display provides at-a-glance information on input/output voltage, load levels, battery status, and estimated runtime, simplifying supervision and maintenance.
- Battery flexibility and reliability: Hot-swappable, front-access battery modules enable maintenance without removing the UPS from service, reducing downtime and keeping critical loads online longer.
- Comprehensive protection and management: Built-in surge protection, voltage regulation (AVR), and multiple communication options (USB/serial; optional network management) for graceful shutdowns, remote monitoring, and integration with existing IT workflows.
Technical Details of Minuteman Endeavor ED1000RTXL2U
- Capacity: 1000 VA (typical output up to ~900 W depending on power factor and load)
- Topology: Online, double-conversion UPS for continuous, clean power and immediate response to outages
- Form factor: 2U rack-mountable, with mounting options for tower or wall installation
- Display: Front-panel LCD showing input/output voltage, load percentage, battery level, and runtime projections
- Battery: Replaceable, hot-swappable battery modules for easy maintenance and reduced downtime
- Protection and regulation: AVR to correct voltage fluctuations without drawing from the battery; surge protection for connected devices
- Communications: USB and serial interfaces for safe shutdown and monitoring; optional network-management interface for remote oversight
- Compatibility and integration: Designed to integrate with common enterprise workflows, backup strategies, and IT asset management tools
- Physical and environmental: Built to withstand typical data-center and office environments with appropriate operating temperature and humidity ranges
How to install Minuteman Endeavor ED1000RTXL2U
- Plan placement: Choose a location with adequate ventilation, stable surface, and access to a standard power outlet. For rack installations, ensure the rack is securely mounted and compatible with 2U devices.
- Mount the unit: If using a rack, install the ED1000RTXL2U into a compatible 19-inch rack; if using a tower configuration, orient the UPS on a flat surface with ample clearance around the rear exhaust area. For wall-mount setups, follow the included hardware and ensure clearance for front-panel visibility and cable connections.
- Connect power and loads: Plug the UPS into a suitable outlet using the appropriate input cord. Connect critical devices (servers, network gear, storage, and telecom equipment) to the UPS’s outlet banks, prioritizing essential loads for optimal runtime distribution during an outage.
- Initialize and configure: Turn on the UPS and verify the LCD display powers up. Use the LCD to confirm input voltage, load, and battery status. Install any required software or drivers on connected servers for automatic graceful shutdowns in power events.
- Test and calibrate: With the UPS under load, perform a controlled battery test if recommended by the user manual. Validate that runtime estimates align with actual conditions, and adjust AVR thresholds or notification settings as needed to match your operational requirements.
Frequently asked questions
-
Q: What does the Minuteman Endeavor ED1000RTXL2U protect?
A: It safeguards critical IT equipment and network infrastructure by supplying a continuous online power source, filtering noise, and enabling automatic shutdown during extended outages. This helps prevent data loss, hardware damage, and service interruptions.
-
Q: Can I mount this UPS in a rack, tower, or on a wall?
A: Yes. The ED1000RTXL2U is designed as a flexible installation solution that supports rack-mount, tower, and wall-mount configurations, making it suitable for data centers, server rooms, and office environments with space constraints.
-
Q: Are the batteries replaceable?
A: Yes. The unit features front-access, hot-swappable batteries for easy maintenance without powering down critical systems. This minimizes downtime and simplifies battery replacement schedules.
-
Q: How can I monitor and manage the UPS?
A: The ED1000RTXL2U includes USB and serial interfaces for safe shutdowns and monitoring. Optional network management interfaces may be available to enable remote status checks, alerts, and integration with centralized monitoring systems.
Customer reviews
Showing - Of Reviews