Description
Minuteman OEPD302L630HVHW 2-Outlets PDU
Power your critical IT infrastructure with the Minuteman OEPD302L630HVHW 2-Outlets PDU. Engineered for reliability in demanding data-center and server-room environments, this compact dual-outlet power distribution unit delivers a clean, secure solution for distributing high-capacity power to essential equipment. With a 30-amp rating and flexible mounting options, it fits neatly into 19-inch racks and cabinets, helping you optimize space, simplify cable management, and maintain consistent power delivery to your servers, switches, storage devices, and other rack-mounted hardware. The OEPD302L630HVHW is designed for hardwired installation, offering a tidy, integrated power distribution footprint that reduces clutter while keeping critical devices energized and ready for operation. Whether you’re deploying a new rack or upgrading an existing setup, this Minuteman PDU provides the dependable distribution you need with straightforward, no-fruss installation and reliable performance under load.
- 2-outlet, 30A configuration tailored for dual high-demand devices: Ideal for servers, switches, network gear, and storage solutions, delivering robust power delivery in a compact form factor.
- Flexible mounting for space optimization: Install in either horizontal or vertical orientation to suit your rack layout, airflow strategy, and cable management needs, making it easy to fit into tight rack spaces.
- Hardwired installation for a clean, secure setup: Connects directly to your main distribution circuit, reducing exposed cords and simplifying integration into existing electrical infrastructure.
- Rugged, compact enclosure built for data centers and server rooms: Designed to withstand busy IT environments while preserving a neat, professional appearance inside your rack enclosure.
- Seamless integration with power management workflows: Supports reliable power distribution without complicated wiring, helping you maintain predictable performance for uptime-critical equipment.
Technical Details of Minuteman OEPD302L630HVHW 2-Outlets PDU
- Model: OEPD302L630HVHW
- Outlets: 2-outlet configuration
- Current rating: 30A
- Mounting: Horizontal or vertical installation
- Connection method: Hardwired
- Form factor: Compact, 19-inch rack-compatible enclosure
how to install Minuteman OEPD302L630HVHW 2-Outlets PDU
Installing the Minuteman OEPD302L630HVHW is straightforward for qualified personnel familiar with rack power distribution. Begin by planning the placement within your rack or cabinet, choosing a location that allows ample airflow and convenient access for maintenance while keeping the two outlets within reach of the devices they will power. Confirm that the electrical circuit you intend to connect to matches the PDU’s 30-amp rating and is appropriate for a hardwired installation. If you are unsure about electrical requirements or local regulations, consult a licensed electrician or your facilities team before proceeding.
1) Prepare the rack and hardware: Clear the mounting area inside the rack, verify that you have the necessary mounting brackets or hardware for a standard 19-inch rack, and ensure you have the correct tools for securing the PDU in place. The compact design of the OEPD302L630HVHW makes it easy to position in tight spaces, but secure mounting is essential to prevent movement during operation.
2) Mount the PDU: Depending on your chosen orientation, align the PDU with the rack rails and secure it using the provided screws or mounting hardware. For horizontal installation, fasten the unit firmly to the rack’s vertical rails; for vertical installation, ensure the device is positioned to allow easy access to both outlets and any cabling connections. Confirm that the enclosure remains level and stable after mounting.
3) Plan and route cables: Route the device power and equipment cables in a tidy manner, using cable ties or management channels to minimize tangling and air-flow obstruction. Keep the two outlets accessible from the front of the rack for maintenance and device replacement, and avoid over-tightening straps that could damage cables. Proper cable management not only improves airflow but also simplifies troubleshooting and component swaps.
4) Make the hardwired connection: Connect the PDU to the appropriate distribution circuit using the correct gauge wiring and termination method as required by your electrical code and facilities standards. This step should be performed by a qualified professional. Ensure all power is off during wiring, verify secure, strain-relieved connections, and double-check any protective devices or circuit breakers in the path of the supply line.
5) Verify operation and test: Restore power and power up connected devices one by one to verify correct operation. Check for any abnormal heating, unusual noises, or unexpected behavior. Monitor the PDU and connected equipment for a period of time to confirm stable performance under typical load conditions. If your environment supports it, integrate the PDU with your standard monitoring tools to track load, temperature, and uptime metrics for ongoing power management.
6) Documentation and labeling: Record installation details, including mounting orientation, circuit details, and outlet assignments. Label the PDU and the connected devices to facilitate future maintenance, upgrades, or reconfigurations. Clear labeling helps ensure quick diagnostics and reduces the risk of miswiring during future renovations.
By following these steps, you can achieve a clean, reliable power distribution setup that aligns with best practices for data centers, IT rooms, and network closets. The OEPD302L630HVHW is designed to integrate seamlessly into standard rack environments, delivering dependable power to two critical devices while preserving space and improving cable management. For ongoing reliability, ensure periodic inspections of connections, mounting integrity, and load distribution to maintain peak performance over the PDU’s service life.
Frequently asked questions
-
Q: What is the amperage rating of the Minuteman OEPD302L630HVHW?
A: The PDU is rated for 30 amps, suitable for high-demand equipment and robust rack power distribution. -
Q: How many outlets does this PDU provide?
A: It features two outlets, designed to power two primary devices or a pair of critical components in a rack setup. -
Q: Can the PDU be mounted horizontally and vertically?
A: Yes. The OEPD302L630HVHW supports both horizontal and vertical mounting to fit your rack configuration and space requirements. -
Q: Is the PDU hardwired?
A: Yes. This model is designed for hardwired installation, providing a clean, secure connection to your electrical distribution system. -
Q: What equipment is best suited for this PDU?
A: It is well-suited for servers, switches, storage devices, and other critical IT gear that benefits from reliable, dedicated power distribution within a 19-inch rack.