Description
Minuteman OEPD304L630HVHW 4-Outlets PDU
The Minuteman OEPD304L630HVHW 4-Outlets PDU is a dedicated power distribution unit designed to meet the demanding needs of modern IT environments. Built for reliability in data centers, server rooms, and network closets, this PDU delivers organized, scalable power distribution that helps protect equipment, streamline cabling, and optimize energy usage. With four outlets, rugged construction, and features tailored for uptime and efficiency, it’s an essential component for any rack with mission-critical gear. Whether you’re deploying new hardware or upgrading an aging power infrastructure, this PDU provides a dependable backbone that simplifies power management and reduces the risk of unexpected downtime.
- 4-Outlets configuration for focused power distribution: Designed to power multiple critical devices such as servers, switches, storage arrays, and network appliances from a single, organized source. The compact 4-outlet layout minimizes clutter while maximizing outlet accessibility in dense rack environments.
- Advanced power management and monitoring: Built to help you control energy usage and improve efficiency, the OEPD304L630HVHW supports essential monitoring capabilities and alerting to identify power anomalies, track consumption, and support capacity planning across IT infrastructure.
- Rugged, rack-ready design: A sturdy enclosure built for 19-inch rack installations, offering reliable performance in data centers, labs, and hot environments. The hard-wired configuration and robust construction ensure stable operation even in demanding workloads.
- Flexible deployment and easy integration: The PDU is designed for straightforward installation in standard IT racks with straightforward cabling, enabling quick deployment and minimal maintenance while keeping cables organized for airflow and space optimization.
- Safety, compliance, and reliability: UL-listed and RoHS-compliant, with safety features and protections that help safeguard connected equipment from power surges and overcurrent conditions while meeting industry standards for quality and environmental responsibility.
Technical Details of Minuteman OEPD304L630HVHW
- Outlets: 4 standard outlets for essential IT devices
- Mounting: 19-inch rack-mountable enclosure for easy integration into standard racks
- Input configuration: Hard-wired input (no power cord) suitable for controlled power delivery in data centers
- Protection: Built-in overcurrent protection and surge protection to defend equipment
- Certifications: UL-listed, RoHS compliant for safety and environmental responsibility
How to install Minuteman OEPD304L630HVHW
Installing the OEPD304L630HVHW is a straightforward process that fits seamlessly into existing data center and IT rack workflows. Begin by selecting a suitable location in a standard 19-inch rack with adequate clearance for airflow and cable management. Ensure the rack surface and mounting rails are stable, and verify that the chosen bay can accommodate the PDU’s hard-wired input connection. With the rack prepared, secure the PDU firmly using the appropriate rack screws to prevent vibration or displacement during operation.
- Step 1: Mount the PDU securely in the selected rack position, aligning mounting holes with the rack rails and tightening fasteners to specification for stability.
- Step 2: Complete the hard-wired power connection per local electrical codes, using the approved service entrance or distribution path and ensuring all safety precautions are followed.
- Step 3: Route power cables and data cables cleanly to minimize clutter, maximize airflow, and simplify future maintenance. Use ties or clips to keep cables organized without obstructing front or rear access.
- Step 4: Connect your IT devices to the PDU’s four outlets, distributing load evenly across devices to prevent overloading a single outlet and to maintain healthy power margins.
- Step 5: Power on the rack, verify that each outlet supplies power to connected equipment, and configure any available monitoring or alerting options to enable proactive management and quick fault detection.
After installation, perform a brief power-on self-check to ensure proper function and confirm that all devices respond as expected. Regularly review energy usage data, and adjust device allocations if needed to optimize efficiency and reduce operational costs over time.
Frequently asked questions
- Q: What environments is the Minuteman OEPD304L630HVHW best suited for? A: It is ideal for data centers, server rooms, network closets, and other IT environments requiring reliable, organized power distribution for multiple devices in a compact rack-friendly form factor.
- Q: Does this PDU offer monitoring or alerting features? A: Yes, it provides essential power management capabilities to help monitor load and detect anomalies, supporting better energy efficiency and uptime. Check alignment with your existing monitoring tools for integration.
- Q: Is the PDU compatible with standard 19-inch racks? A: Absolutely. It is designed for standard 19-inch rack installations and is built to fit within common rack footprints used in data centers and IT closets.
- Q: What safety certifications does it have? A: The OEPD304L630HVHW is UL-listed and RoHS compliant, ensuring compliance with safety standards and environmental requirements for professional IT deployments.
Customer reviews
Showing - Of Reviews