Minuteman RPM2016I2LCD-L20P 16-Outlets PDU

MinutemanSKU: 6361711

Price:
Sale price$1,712.53

Description

Minuteman RPM2016I2LCD-L20P 16-Outlets PDU

The Minuteman RPM2016I2LCD-L20P 16-Outlets PDU is engineered to give IT professionals a reliable, scalable, and efficient power distribution solution for data centers, server rooms, and network closets. Designed to simplify complex power layouts, this compact yet powerful PDU combines robust hardware with intelligent management features to deliver real-time visibility, control, and protection for critical devices. Whether you’re building a new rack, upgrading an existing setup, or looking to reduce energy waste, the RPM2016I2LCD-L20P is built to meet the demanding needs of modern IT environments while helping you keep operating costs under control.

With 16 outlets distributed across a rugged, rack-mountable chassis, this unit provides strategic power distribution right where you need it most. The integrated LCD on the front panel delivers immediate, at-a-glance status information, while remote management capabilities give you the flexibility to monitor and control your power environment from anywhere on the network. This combination of local visibility and remote intelligence makes the RPM2016I2LCD-L20P an indispensable tool for administrators seeking uptime, performance, and efficiency without sacrificing convenience.

  • 16-outlet power distribution for compact rack footprint, enabling clean, organized wiring and scalable expansion across multi-rack deployments.
  • Front-panel LCD for quick diagnostics and at-a-glance status updates, reducing time-to-response for power events and device faults.
  • Remote power management with secure access to monitoring data, outlet control, and event alerts to safeguard connected equipment from unexpected outages.
  • Rack-mount convenience with a durable chassis designed for dense data centers, labs, and network closets, supporting standard 19" rack installations.
  • Energy visibility and efficiency through real-time load monitoring and reporting, helping you identify underutilized assets and optimize energy usage across the environment.

Technical Details of Minuteman RPM2016I2LCD-L20P

  • Model: RPM2016I2LCD-L20P
  • Outlet count: 16
  • Display: LCD front panel
  • Mounting: Rack-mountable 19" chassis
  • Brand: Minuteman
  • Power distribution type: PDU for network devices and IT equipment

How to install Minuteman RPM2016I2LCD-L20P

  • Step 1 — Prepare the rack: Select a clean, stable 19" rack with adequate ventilation and adjacent outlets for power delivery to the PDU itself and to the devices you plan to attach.
  • Step 2 — Mount the PDU: Slide the RPM2016I2LCD-L20P into the rack rails and secure it with the provided screws. Ensure there is enough clearance for the front-panel LCD for readable status updates.
  • Step 3 — Connect the power input: Attach the PDU’s primary power cord to a properly rated power source. Verify that the input voltage and amperage align with the PDU’s specifications and the facility’s electrical code requirements.
  • Step 4 — Populate and organize outlets: Plug your network devices, servers, switches, and other critical systems into the 16 outlets. Use cable management practices to minimize clutter and maximize airflow around the rack.
  • Step 5 — Establish network and monitoring access: Configure any available remote management interfaces (web, SNMP, or other supported protocols) and set up alerts for power events. If the LCD supports local configuration, follow the on-device prompts to complete setup.
  • Step 6 — Verify operation: Power on connected devices, confirm outlet control works, and test remote access and notification settings. Check the LCD for live load and status indicators to ensure the PDU is functioning correctly.
  • Step 7 — Document and secure: Record the PDU’s location, power plan, and alert thresholds in your asset management system. Ensure physical security of cables and restrict access to authorized personnel as part of your facility’s security policy.

Frequently asked questions

  • What is the RPM2016I2LCD-L20P? A 16-outlet Minuteman PDU with an LCD interface designed for reliable power distribution and remote management in data centers, labs, and network closets.
  • How many outlets does it have? It features 16 outlets to support a wide range of connected devices in a compact 19" rack footprint.
  • Does it offer remote monitoring? Yes, the RPM2016I2LCD-L20P provides remote management capabilities so administrators can monitor and control power delivery from a centralized interface.
  • Is the front LCD useful for day-to-day operations? The LCD provides on-site visibility into load, status, and diagnostics, enabling quick checks without needing to access the management console.
  • How does it help with energy efficiency? Real-time load monitoring and outlet-level visibility enable better power budgeting, anomaly detection, and opportunities to balance loads and reduce waste.
  • Can it be installed in standard data center racks? Yes, it is designed for standard 19" rack installations, making it compatible with most data center, lab, and office IT environments.