Minuteman RPM204I2LCD-L20P 4-Outlets PDU

MinutemanSKU: 6361707

Price:
Sale price$1,016.16

Description

Minuteman RPM204I2LCD-L20P 4-Outlets PDU

The Minuteman RPM204I2LCD-L20P 4-Outlets PDU delivers reliable, scalable power distribution with intelligent remote control features designed for data centers, server rooms, and critical network closets. Built to streamline power management, this PDU helps administrators keep devices online, reduce downtime, and simplify routine maintenance—all from a centralized console or directly at the unit’s LCD interface.

  • Four outlets provide flexible power distribution for servers, switches, routers, and ancillary devices, enabling clean cabling and organized rack layouts while accommodating growth in busy IT environments.
  • Remote power management is at the core of this PDU, allowing admins and technicians to cycle outlets, reboot connected equipment, and perform power-related maintenance without on-site visits—minimizing disruption and accelerating issue resolution.
  • The integrated LCD display gives instant visibility into on-rack power status, outlet activity, and basic diagnostics, so you can quickly verify device health, perform on-the-fly reboots, and adjust configurations without relying on external monitoring tools.
  • The rugged 19-inch rack-mountable design is purpose-built for data centers, labs, and telecom rooms, delivering a compact, space-efficient solution that fits neatly into standard racks while supporting clean, professional installations.
  • Designed for administrators and field technicians, this RPM-series PDU emphasizes uptime, control, and efficiency—empowering teams to manage power proactively, reduce mean time to repair, and keep critical devices operational during peak demand or hardware changes.

Technical Details of Minuteman RPM204I2LCD-L20P

  • Brand: Minuteman
  • Model: RPM204I2LCD-L20P
  • Outlets: 4
  • Form factor: 19-inch rack-mountable enclosure
  • Display: LCD status display for local monitoring
  • Management: Remote power control and basic status monitoring
  • Mounting: Designed for standard data center racks to support organized, scalable deployments

How to install Minuteman RPM204I2LCD-L20P

Step 1: Prepare your rack space and ensure you have a clean, vibration-free mounting area. Verify that the rack bay can accommodate a 19-inch rack-mountable PDU and that there is adequate clearance for the LCD display to be read without obstruction. This first step helps prevent airflow and accessibility issues later in the deployment.

Step 2: Mount the RPM204I2LCD-L20P securely in the rack using the supplied hardware. Align the chassis with the rack rails, insert the mounting screws, and tighten evenly to avoid bracket flex. A properly mounted PDU minimizes vibration and ensures stable operation during power cycling and preventive maintenance.

Step 3: Connect the PDU to a dedicated power source that meets the environment’s electrical requirements. Use appropriate power cords and ensure a clean power feed to prevent nuisance tripping or brownouts. Confirm that the installed outlet strip configuration matches your device placement plan.

Step 4: Attach your IT equipment to the four outlets, keeping critical devices on separate outlets where possible to maximize fault isolation. Label cables and outlets for easy mapping between devices and their respective outlets, which simplifies future maintenance and incident response.

Step 5: Power on the devices and use the LCD display on the PDU to verify outlet status. If available, configure basic settings from the LCD and test remote power cycling by rebooting a connected device to confirm that the remote control function is working as intended. Document the configuration for future reference.

Step 6: If your environment supports it, integrate the PDU into your broader power management strategy. Depending on the model and facility, you may connect the PDU to centralized monitoring systems or management consoles to enable consolidated alerting, trend analysis, and scripted power events. Maintain security best practices by restricting management access to authorized personnel.

Frequently asked questions

  • What is the Minuteman RPM204I2LCD-L20P? It is a four-outlet power distribution unit (PDU) designed for 19-inch racks, featuring an LCD interface for local status display and remote power control capabilities to simplify device management in data centers, labs, and telecom rooms.
  • How many outlets does it have? The RPM204I2LCD-L20P provides four outlets for flexible distribution of power to connected equipment, enabling organized cabling and efficient use of rack space.
  • Can I manage it remotely? Yes. The PDU supports remote power control to reboot devices and monitor outlet status from a distance, reducing the need for on-site visits during maintenance or outage recovery.
  • Is this PDU rack-mountable? Yes, it is designed for standard 19-inch racks and typically fits within a 1U or similarly compact footprint, making it suitable for a wide range of data center and network closet installations.
  • What environments is this PDU best suited for? It is ideal for data centers, server rooms, labs, and telecommunications closets where centralized power management, uptime, and efficient space utilization are priorities.