Description
Minuteman RPM208N1LCD-20P: 8-Outlets IP‑Addressable PDU
The Minuteman RPM208N1LCD-20P 8-Outlets PDU is a rugged, IP‑addressable power distribution solution designed for modern data centers, network closets, and security deployments. Built for proactive, remote power management, this PDU joins the RPM EV6 and LCD series to give administrators total visibility and control over connected devices without costly site visits. With an integrated LCD interface and scalable remote management, you can power cycle servers, networking gear, and security appliances from anywhere, ensuring uptime and rapid issue resolution.
- IP-addressable remote power control lets you monitor, manage, and power cycle connected equipment from any network, reducing mean time to repair and eliminating unnecessary on-site visits. This capability is ideal for data centers, remote office deployments, and mission-critical environments that demand instant access to power status and control.
- 8 outlets in a compact 19-inch form factor provide a focused distribution solution for essential gear such as servers, switches, storage devices, and monitoring appliances. The 8‑outlet design supports clean rack wiring and efficient load distribution, helping you maximize cabinet space while keeping critical hardware energized when you need it most.
- RPM EV6 LCD series integration combines robust hardware with a user-friendly LCD interface, delivering on-device status at a glance while enabling advanced remote management through standard network protocols. The LCD display complements remote access, offering quick, tactile feedback during maintenance and setup.
- Secure, scalable management supports centralized control for entire campuses or data centers. By consolidating power control, event logging, and outlet monitoring into a single, networked device, the RPM208N1LCD-20P helps IT teams enforce policies, track energy usage, and respond rapidly to anomalies.
- Simple installation and flexible mounting in a standard 19" rack provides versatile integration into existing infrastructure. The PDU is designed to work with a variety of rack layouts, making it suitable for both new builds and retrofits where space, power, and management capabilities must align.
Technical Details of Minuteman RPM208N1LCD-20P 8-Outlets PDU
- Model: RPM208N1LCD-20P
- Outlets: 8 (8-Outlets PDU configuration)
- Series: RPM EV6 and LCD
- IP Addressable: Yes
- Display: Integrated LCD on RPM EV6 LCD series
- Management: Network-enabled remote power control and monitoring
- Mounting: 19-inch rack-mount capable
- Access: Local LCD interface and remote web/SSH-like network access for management
how to install Minuteman RPM208N1LCD-20P
- Prepare the rack space: Identify a suitable 19" rack location with adequate airflow and clearance for the PDU’s LCD panel and front LEDs. Confirm power availability and network connectivity to the data center’s management network.
- Mount the PDU: Slide the RPM208N1LCD-20P into the rack rails and secure it with screws. Ensure the unit is level and that the front LCD display remains accessible for local status checks and quick troubleshooting.
- Connect input power: Plug the PDU into a suitable power source that matches the device’s rating. Use a dedicated circuit if possible to avoid drawing power from mixed or overloaded circuits. Leave space for cable management behind the rack to prevent airflow obstruction.
- Establish network access: Connect the PDU’s management interface to your data center network using a standard Ethernet connection. If available, assign a static IP address or integrate with your DHCP server and reserve the address for consistent remote access.
- Configure the PDU: Using the on-device LCD or the web-based management interface, configure administrator credentials, access permissions, and outlet naming conventions. Set up alert thresholds, event logging, and remote power-control policies to match your IT operations standards.
- Test and validate: Power on connected devices in a controlled sequence, verify individual outlet control (on/off), monitor real-time current draw if supported, and confirm that alerts are delivered to the network management system. Document the configuration for future audits and maintenance.
Frequently asked questions
- What is the RPM EV6 LCD series? The RPM EV6 LCD series comprises IP‑addressable power distribution units designed for remote power management with an integrated LCD interface, combining on-device visibility with network-based control for scalable data-center operations.
- How many outlets does the RPM208N1LCD-20P have? This model features eight outlets, arranged in a compact 19" rack-mount form factor suitable for essential servers, switches, storage devices, and related equipment.
- Can I manage this PDU remotely? Yes. The RPM208N1LCD-20P is IP-addressable and supports network-based power control, monitoring, and event logging, enabling you to manage power and receive alerts from any approved management console.
- Is on-site access available? Yes. The built-in LCD on the RPM EV6 LCD series provides local status information and quick controls without needing to remote in, which is helpful during maintenance windows or when network access is temporarily unavailable.
- What environments is this PDU best suited for? The RPM208N1LCD-20P is ideal for data centers, enterprise IT rooms, branch offices, and security deployments where reliable power distribution, remote management, and rapid problem resolution are critical to uptime.
- What mounting and compatibility options should I consider? Plan for a standard 19-inch rack installation with space for cable management and airflow. The PDU is designed for rack-mount deployment and integrates with RPM EV6 LCD series accessories and compatible management tools used in professional IT environments.