Minuteman RPM308I2LCD-L30P 8-Outlets PDU

MinutemanSKU: 6361715

Price:
Sale price$1,217.83

Description

Minuteman RPM308I2LCD-L30P 8-Outlets PDU

Discover powerful, scalable power management with the Minuteman RPM308I2LCD-L30P 8-Outlets PDU. This IP-based switched PDU is purpose-built for demanding data centers, labs, and enterprise racks that require precise control, reliable monitoring, and secure access to power distribution. With eight independently controllable outlets, a 208V input, and a robust 30A rating, it enables granular management of critical devices while helping you optimize uptime, energy efficiency, and operational visibility. The RPM308I2LCD-L30P goes beyond basic power strips by offering enterprise-grade features such as IPv6-ready network management, LCD status display, event logging, and alerting that keeps you in the loop—whether you’re on-site or managing remotely.

  • The RPM308I2LCD-L30P is an IP-based switched PDU with eight outlets, designed to deliver reliable, remotely controllable power to servers, storage, and networking gear. With a 208V input and a 30A maximum rating, it supports high-density rack deployments and sophisticated load distribution. Its individual outlet control enables you to power-cycle specific devices without affecting the entire rack, reducing downtime and simplifying maintenance windows. The PDU’s architecture is built to handle surge protection, minimize voltage sag, and improve overall rack reliability by isolating critical equipment from less important loads.
  • Networked management is at the heart of this unit. The RPM308I2LCD-L30P features IPv6 compatibility alongside traditional IPv4 support, providing modern, scalable network addressing for large deployments. A secure web-based management interface, along with standard management protocols, lets administrators configure, monitor, and control outlets from anywhere on the network. Role-based access, secure authentication, and event logging enable teams to enforce governance and keep a clear record of who changed what and when, which is essential for audits and compliance.
  • Real-time diagnostics are visible at a glance thanks to the built-in LCD display. The screen presents key data such as total power draw, per-outlet status, and important alarms, reducing the need to blindly SSH into the device for quick checks. This on-device feedback accelerates triage during outages or maintenance. In addition to live readings, the PDU maintains an event history so you can review past incidents, identify trends, and adjust your power strategy accordingly.
  • Power management and alerting features are designed for proactive control. The RPM308I2LCD-L30P supports alerts for overcurrent, outages, and abnormal load conditions, with notification options through the management interface, such as email or trap-based notifications. You can implement load balancing policies, schedule power sequencing to prevent inrush surges during boot, and group outlets for synchronized control—streamlining routine reboots and ensuring smooth device bring-up during maintenance windows.
  • Physical design and installation versatility make this PDU a practical choice for modern data centers. It is engineered for standard 19-inch rack installations with a secure enclosure and clear labeling for effortless wiring. Built to endure the rigors of a busy rack, the RPM308I2LCD-L30P includes robust cabling options, protected ports, and status LEDs to quickly identify connectivity and power status. Its compact footprint and thoughtful cable management support tidy, scalable setups, while enabling quick replacements and easy upgrades as your infrastructure evolves.

Technical Details of Minuteman RPM308I2LCD-L30P

  • Model: RPM308I2LCD-L30P
  • Outlets: 8
  • Input voltage: 208 VAC
  • Current rating: 30 A
  • Maximum output power: 6.24 kW (208 V × 30 A)
  • Management: IP-based with IPv6 and IPv4 support, web interface, SNMP, and email alerting
  • Display: Integrated LCD for real-time status and outlet information
  • Form factor: 19-inch rack-mountable design for standard data center racks
  • Security: Role-based access control and secure authentication for remote management
  • Monitoring: Real-time load monitoring, event logging, and outage history

How to install Minuteman RPM308I2LCD-L30P

  • Plan your rack layout by identifying a suitable 19-inch rack location with adequate clearance for cable management and cooling. Ensure the mounting area is clean and free of obstructions, and verify that the shelf or cabinet can accommodate the PDU’s depth and mounting brackets.
  • Mount the PDU securely in the rack using the included brackets or mounting hardware. Align the unit with the rack’s vertical rails, insert screws at the designated mounting points, and tighten to a firm, level fit. Confirm that outlet labeling and cable pathways are respected to avoid interference with other equipment and airflow.
  • Connect the power input to a dedicated 208V, 30A circuit that matches local electrical codes. Use appropriate power cables and connectors, ensuring a clean, secure connection. If you have multiple power feeds, follow your data center’s power distribution plan to balance loads and prevent nuisance tripping during startup.
  • Establish network connectivity for IP-based management. Attach an Ethernet cable to the PDU’s management port and connect it to your management switch or router. Configure the PDU’s network settings, including IPv6 addressing (and IPv4 as needed), gateway, and DNS. Create strong admin credentials and enable secure access (HTTPS) to protect management traffic.
  • Access the web management interface from a workstation on the same network. Use the displayed or documented IP address to log in, apply firmware updates if available, and configure critical settings. Create outlet groups, set power sequencing schedules, and tailor alert thresholds. Validate that each outlet responds to remote on/off commands and that alerts are delivered to the correct team members. Finally, perform a controlled power cycle of a selected outlet to verify reliable remote control and recovery.

Frequently asked questions

  • Q: What is the Minuteman RPM308I2LCD-L30P used for? A: It is an IP-based switched PDU designed to provide eight independently controllable outlets for reliable, remotely managed power distribution in racks. It enables granular power control, monitoring, and alerting to support uptime and performance of critical IT and network equipment.
  • Q: Does this PDU support IPv6? A: Yes. The RPM308I2LCD-L30P is designed with IPv6 compatibility to meet modern network management requirements while maintaining IPv4 support for broader compatibility.
  • Q: How many outlets does it have and what is the voltage? A: It features eight outlets and operates from a 208V input with a maximum current rating of 30A, suitable for mid- to high-density rack environments.
  • Q: Can I monitor energy usage and receive alerts? A: Yes. The PDU provides real-time load data, outlet status, and event logs through its web interface, plus alerting options such as email notifications and SNMP traps for proactive management.
  • Q: Is it compatible with standard 19-inch racks? A: Yes. The RPM308I2LCD-L30P is designed for standard 19-inch rack installations and includes mounting options that support secure, reliable deployment in conventional data center racks.
  • Q: What security features are included? A: The device supports secure authentication, role-based access control, and encrypted management communications to help protect sensitive power-management operations.
  • Q: How do I perform routine maintenance or firmware updates? A: Use the web management interface to check for firmware updates, apply them following the vendor’s guidelines, and restart the PDU if required. Keep a log of changes for audits and maintenance records.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed