Description
Minuteman RPM308N1LCD-L30P 8-Outlets PDU
The Minuteman RPM308N1LCD-L30P 8-Outlets PDU is a high-performance power distribution solution engineered for data centers, server rooms, and network ecosystems that demand precise power control and reliable uptime. Designed to optimize rack power management, this PDU combines a robust, rack-ready chassis with an intuitive LCD interface and network-enabled capabilities, enabling IT teams to monitor, control, and optimize power delivery to critical devices from both local and remote locations. From rapid power cycling of individual outlets to real-time status reporting, the RPM308N1LCD-L30P helps reduce mean time to repair (MTTR) and improve overall infrastructure efficiency through smarter, more granular power management.
- Remote power control and monitoring: Manage individual outlets, schedule reboots, and monitor power events from the front LCD panel and through secure network access. This enables quick remediation of issues without on-site visits and supports proactive maintenance workflows.
- Eight independent outlets: A compact, eight-outlet distribution solution that allows precise distribution of power to servers, switches, storage, and other rack-mounted devices. Each outlet can be controlled independently to optimize load balancing and reboot sequences.
- Rack-ready design: Built for standard 19-inch racks, the RPM308N1LCD-L30P ships with compatible mounting hardware to fit neatly into data center racks, reducing clutter and maximizing space efficiency while maintaining electrical safety and reliability.
- Intelligent power features: The unit includes essential protections and smart capabilities such as surge protection, input voltage sensing, and power sequencing options to minimize device startup surges and protect critical equipment from power anomalies.
- Secure, accessible management: Access control and logging provide a clear audit trail for all power actions. Whether you’re on-site or remote, administrators can ensure authorized use and traceability for compliance and uptime management.
Technical Details of Minuteman RPM308N1LCD-L30P 8-Outlets PDU
- Model: RPM308N1LCD-L30P
- Outlets: 8 independently controllable outlets for granular power management
- Display: LCD status panel provides real-time information and quick at-a-glance status
- Mounting: 19-inch rack-mountable chassis with included hardware for standard data center installations
- Power input: Supports single-phase AC input suitable for typical data center power environments
- Network management: Network-enabled for remote monitoring and control (secure access via supported management interfaces)
- Protection features: Surge protection and voltage sensing to guard connected equipment against abnormalities
- Power sequencing: Built-in sequencing capabilities to optimize startup/shutdown of connected devices
- Security: Access controls and event logging to ensure authorized use and traceability
How to install Minuteman RPM308N1LCD-L30P
- Prepare the rack space: Ensure the rack is clean, stable, and capable of supporting the RPM308N1LCD-L30P along with its intended load. Verify clear air circulation around the unit to prevent overheating.
- Mount the PDU: Use the provided hardware to secure the RPM308N1LCD-L30P to the 19-inch rack rails. Align the unit with the rack’s mounting points and tighten screws evenly to avoid distortion.
- Connect power: With the main power off, connect the PDU’s input power cord to the appropriate electrical supply. Verify voltage compatibility and ensure all safety protocols are followed during connection.
- Attach connected devices: Plug servers, switches, and other rack-mounted equipment into the eight outlets. Distribute loads evenly to prevent overloading any single outlet or bank of outlets.
- Configure management: Power up the rack and use the LCD panel to verify basic status. If applicable, connect the PDU to your network and configure remote access, user permissions, and alert settings according to your organization’s security policies.
- Set preferences and labels: Use the LCD interface to label each outlet, configure power sequencing options, and set up schedules or alerts that align with your maintenance windows and uptime requirements.
- Test and validate: Perform a controlled power-on sequence to ensure all devices boot correctly. Confirm that outlet controls and monitoring are functioning as intended, and verify remote access from your management system.
Frequently asked questions
-
What is the Minuteman RPM308N1LCD-L30P?
The RPM308N1LCD-L30P is an eight-outlet power distribution unit designed for data centers and server rooms. It combines a rugged rack-mountable chassis with an intuitive LCD display and network-enabled management to provide granular control and monitoring of connected equipment. -
How many outlets does it have?
It features eight independently controllable outlets for precise distribution and power sequencing of critical devices. -
Can I monitor and control the PDU remotely?
Yes. The RPM308N1LCD-L30P supports remote management via network connectivity, allowing you to monitor status, control outlets, and receive alerts without physically accessing the rack. -
Is the PDU compatible with standard data center racks?
Yes. It is designed for standard 19-inch racks and ships with the necessary mounting hardware for straightforward installation in typical data center environments. -
What kind of protection and safety features are included?
The unit includes essential surge protection, voltage sensing, and secure access controls to help protect equipment and ensure that only authorized users can perform power actions. -
How do I configure power sequencing and scheduling?
Power sequencing and scheduling can be configured via the LCD interface or through your network management interface, enabling you to define safe startup/shutdown orders and maintenance windows for connected devices. -
Do I need special software to manage this PDU?
Basic management is accessible via the LCD panel; advanced remote management may be achieved through compatible network management software or interfaces supported by your IT environment.
Customer reviews
Showing - Of Reviews