Description
Monnit ALTA Industrial Wireless Voltage Meter - 0-200 VDC
The Monnit ALTA Industrial Wireless Voltage Meter is a compact, rugged sensing solution designed to monitor DC voltage remotely in demanding industrial environments. Capable of measuring voltage up to 200 VDC, this sensor connects directly to the positive and ground terminals of the device under test, capture readings with high accuracy, and transmit them wirelessly to your Monnit gateway and cloud dashboard. Built for reliability, the ALTA series delivers real-time insights for battery banks, DC power rails, motor controllers, and other critical equipment, helping facilities stay informed, reduce downtime, and optimize energy management without the complexity of wired instrumentation. Whether you’re monitoring a remote battery bank in a manufacturing line or validating DC supply integrity across a distributed system, this voltage meter provides a simple, scalable path to continuous monitoring and proactive maintenance.
- Direct voltage sensing through leads: Attach the sensor’s leads to the positive and ground terminals of the device being measured to obtain accurate, real-time DC voltage readings without interrupting circuit operation.
- Industrial wireless data transmission: The ALTA sensor communicates measurements wirelessly to a Monnit gateway, enabling centralized monitoring and data collection across facilities, campuses, or remote sites.
- Real-time monitoring with configurable alerts: Receive instant updates when voltage deviates from your set thresholds, enabling proactive maintenance, faster issue resolution, and reduced unplanned downtime.
- Compact, rugged design for harsh environments: Engineered to withstand industrial conditions, the ALTA voltage meter integrates into tight spaces and aligns with standard installation practices in factories, warehouses, and service yards.
- Seamless integration with Monnit platforms: Publish data to the Monnit Cloud, dashboards, and APIs, supporting robust analytics, historical trends, and easy integration with existing BMS or IoT workflows.
Technical Details of Monnit ALTA Industrial Wireless Voltage Meter
- Voltage range: 0-200 VDC
- Measurement method: Leads connect to the device's positive and ground terminals to capture DC voltage
- Wireless communications: Part of the Monnit ALTA wireless sensing family, designed for reliable remote data transmission to Monnit gateways
- Physical form: Compact, industrial-grade enclosure suitable for mounting in challenging environments
- Power and operation: Self-contained device within the Monnit ecosystem, designed to operate with standard Monnit gateway infrastructure
- Data management: Data streams to the Monnit Cloud with options for dashboards, historical charts, and alerting rules
What makes the Monnit ALTA voltage meter unique?
The ALTA voltage meter is built to simplify DC voltage monitoring where wired instrumentation is impractical or cost-prohibitive. Its unique combination of direct-measurement capability, rugged industrial design, and wireless cloud connectivity gives engineers and facility managers a scalable solution that reduces installation complexity and accelerates time-to-value. With a straightforward two-lead connection to the positive and ground terminals, technicians can capture accurate voltage snapshots and continuous data without powering down systems or performing invasive wiring. The wireless transmission eliminates the need for extensive cable runs, enabling monitoring across large facilities, outdoor sites, or multi-building campuses. Because the data lands in Monnit’s cloud and is accessible via dashboards and APIs, teams can implement proactive maintenance strategies, compare performance across equipment or locations, and create alerts that trigger maintenance tickets or automation workflows. This combination of ease-of-use, resilience, and data-driven insights makes the ALTA voltage meter a compelling choice for energy management, equipment maintenance, and reliability engineering in DC-powered environments.
In addition to basic measurement, the device supports flexible deployment: installers can place the sensor in a position that minimizes wiring complexity while maintaining secure, stable data transfer. The ALTA meter is designed to work within the broader Monnit ecosystem, so it integrates with gateways, triggers, and dashboards that organizations already depend on for asset tracking, energy usage, and predictive maintenance. For teams looking to standardize DC voltage monitoring across multiple sites, the Monnit ALTA voltage meter provides a consistent data model, uniform alerting, and scalable data storage that grows with the organization’s monitoring needs.
Operational reliability is complemented by an emphasis on safety and best practices. The two-lead measurement method preserves the integrity of the device under test and minimizes the risk of disturbances to sensitive equipment. The rugged construction supports installation in environments with dust, vibration, or moderate temperature fluctuations, making it suitable for automation floors, utility rooms, or outdoor enclosures where DC power systems are critical. For facilities prioritizing uptime, the ability to monitor voltage in real time and respond promptly to deviations translates into measurable improvements in equipment longevity, energy efficiency, and overall reliability.
How to install Monnit ALTA Industrial Wireless Voltage Meter
Installing the ALTA voltage meter is designed to be intuitive and fast, enabling technicians to deploy a monitoring solution without heavy rewiring or complex configuration. Follow these general steps to install the sensor and begin collecting data:
- Plan the installation: Identify the DC power source or device whose voltage you want to monitor. Determine a secure mounting location that minimizes exposure to moisture, dust, and excessive vibration while keeping the measurement leads short and tidy.
- Prepare the measurement points: Ensure that the positive and ground terminals you will connect to are accessible, clearly labeled, and safe to work with. De-energize the circuit if required by your safety protocols, and use appropriate PPE as needed.
- Connect the sensor leads: Attach one lead to the device’s positive terminal and the other to the ground (negative) terminal. Secure connections to prevent loose contact, and route wires away from high-heat sources or moving parts.
- Mount the ALTA meter: Place the sensor in its designated location and fasten it according to your facility’s standard mounting practices. Ensure the device has a stable orientation and is protected from direct exposure to water or contaminants where applicable.
- Pair with a Monnit gateway: Power up the sensor and initiate the pairing process with your Monnit gateway following your organization’s standard procedures. Verify the sensor appears in the gateway’s device list and confirm a healthy status is reported.
- Configure monitoring and alerts: Access the Monnit cloud dashboard to set voltage thresholds, sampling rate, and alert rules. Define who should be notified and through which channels (email, SMS, or integration with an BMS/IoT platform).
- Validate readings and dashboards: Confirm that voltage data appears in real time on the dashboard. Compare readings with known reference values to ensure accuracy and reliability of the installation.
Maintenance and calibration considerations: Regularly review sensor placement, lead integrity, and gateway connectivity to maintain data quality. If readings drift or a sensor’s status shows intermittent communication, inspect connections and the surrounding environment for sources of interference or physical damage. With Monnit’s cloud-native architecture, you can reconfigure sampling rates and alert thresholds as your monitoring needs evolve, without intrusive hardware changes.
Frequently asked questions
What does the Monnit ALTA Industrial Wireless Voltage Meter do? It provides remote DC voltage monitoring by measuring voltage from an external device through simple two-lead connections and transmitting the data wirelessly to a Monnit gateway and cloud dashboard for real-time visibility, alerts, and historical analysis.
What voltage range does it support? The device is designed to measure 0-200 VDC, covering common DC power applications such as battery banks, DC power rails, and DC-driven equipment in industrial settings.
How is the sensor installed? Installation involves connecting the leads to the device’s positive and ground terminals, mounting the sensor in a suitable location, and pairing it with a Monnit gateway. After pairing, configure thresholds, sampling rates, and alert rules in the Monnit cloud dashboard.
Do I need a Monnit gateway to use this sensor? Yes. The ALTA wireless voltage meter transmits data to a Monnit gateway, which then forwards data to the Monnit Cloud. The gateway is essential for centralized monitoring and access to dashboards and APIs.
Can I use this sensor across multiple locations? Absolutely. The wireless design supports deployment across campuses or multiple sites, with data aggregated in the cloud for centralized management and cross-location analysis.
How do I access historical data and analytics? All voltage readings are streamed to the Monnit Cloud, where you can build dashboards, generate reports, and run analytics to identify trends, performance degradation, or the impact of changes in load on DC power systems.
What kinds of alerts can I configure? You can configure threshold-based alerts (high/low voltage), rate-of-change alerts, and periodic reporting. Alerts can be delivered via email, SMS, or integrated into other enterprise systems through APIs.
The Monnit ALTA Industrial Wireless Voltage Meter represents a practical blend of simplicity and sophistication for anyone responsible for DC voltage monitoring in industrial environments. Its direct measurement approach, combined with robust wireless capabilities and seamless cloud integration, empowers teams to monitor critical power paths with minimal intrusion and maximum reliability. Whether you’re expanding a monitoring program, upgrading existing instrumentation, or deploying a new remote sensing solution, this voltage meter can help you achieve consistent visibility, faster issue resolution, and smarter energy and asset management across your operation.
Customer reviews
Showing - Of Reviews