Monnit ALTA Serial MODBUS Gateway (900 MHz)

MonnitSKU: 5516876

Price:
Sale price$243.05

Description

Monnit ALTA Serial MODBUS Gateway (900 MHz)

The Monnit ALTA Serial MODBUS Gateway is a purpose-built data concentrator that unifies Monnit’s ALTA wireless sensor networks with traditional Modbus-enabled devices. Designed for industrial environments, this gateway blends breakthrough wireless connectivity with robust serial interfacing to deliver reliable, scalable, and secure data flow from remote sensors to your control systems. By integrating the ALTA Access Point Node (APN) with RS-232C and RS-485 hardware, it creates a seamless bridge between modern wireless monitoring and legacy Modbus equipment, empowering facilities to monitor, control, and optimize operations with precision and ease.

  • Unified wireless-to-Modbus data hub: The ALTA Serial MODBUS Gateway acts as a centralized data concentrator for your ALTA wireless sensor network while providing Modbus compatibility to your existing devices. This means you can collect, aggregate, and route sensor data from dozens or hundreds of wireless nodes into your Modbus-enabled systems without reconfiguring your entire control architecture.
  • Integrated ALTA APN technology: Built-in ALTA Access Point Node capabilities streamline deployment by eliminating the need for separate components. The gateway naturally communicates with ALTA gateways and sensors, enabling rapid commissioning and straightforward fleet management across multiple sites or zones. It’s ideal for facilities seeking scalable expansion without adding complexity.
  • Reliable serial interfacing for legacy equipment: With RS-232C and RS-485 interfaces, the gateway connects directly to Modbus RTU equipment, PLCs, meters, and other serial devices. This enables you to leverage the strengths of your existing instrumentation while enjoying the benefits of wireless monitoring for peripheral sensors and remote assets. The combination supports standard Modbus messaging, enabling familiar integration patterns for plant engineers and automation professionals.
  • 900 MHz wireless coverage for large facilities: Operating in the Monnit ALTA 900 MHz frequency band, the gateway delivers long-range, low-power wireless communication across warehouses, campuses, factories, or outdoor installations. The 900 MHz footprint provides robust signal propagation through walls and equipment, helping you achieve comprehensive coverage with fewer access points and less network complexity.
  • Industrial-grade design with security and manageability: The gateway is built to withstand real-world conditions in industrial settings. It combines rugged hardware with secure data transmission, encryption, and cloud-enabled or on-site management options. The device supports remote monitoring, alerting, and configuration management via the Monnit platform, giving you visibility and control from anywhere at any time.

Technical Details of Monnit ALTA Serial MODBUS Gateway

  • Wireless technology: Monnit ALTA 900 MHz network for long-range, low-power sensor communication
  • Serial interfaces: RS-232C and RS-485 to connect Modbus RTU devices
  • Supported protocol: Modbus RTU/ASCII over serial; seamless integration with Modbus masters
  • Core function: Data concentrator that aggregates ALTA wireless data and forwards Modbus information to control systems
  • Integrated hardware: ALTA Access Point Node (APN) functionality for simplified deployment
  • Power and enclosure: Industrial-grade housing designed for harsh environments; compatible with standard DC power supplies
  • Security: Secure communications, encryption options, and remote management through the ALTA management platform
  • Certifications: Typical industrial certifications as applicable (FCC/IC/CE) for compliant operation
  • Compatibility: Works with Monnit ALTA ecosystem and compatible Modbus devices and masters
  • Maintenance: Remote firmware updates and configuration management via cloud or on-site tooling

How to install Monnit ALTA Serial MODBUS Gateway

  • Unpack and mount the gateway in a secure, ventilated area close to power and the devices it will serve. Ensure it has a clear path to wireless sensors and a stable mounting surface.
  • Provide power using the recommended DC supply and verify that all indicators light up according to the installation guide. Confirm there is adequate network reach to ALTA APN nodes and the Modbus master device.
  • Connect your Modbus devices to the RS-232C or RS-485 serial ports. Use shielded cabling where appropriate and set correct baud rates, parity, and stop bits to match the Modbus master configuration.
  • Associate the gateway with the Monnit ALTA Access Point Node (APN) and your ALTA sensor network. Validate wireless connectivity and confirm that wireless nodes are reporting to the gateway as expected.
  • Configure Modbus addressing and data mapping so Modbus masters can poll the desired registers. Test read/write operations with a trusted Modbus master to verify data integrity and timing. Monitor logs and dashboards for any anomalies and adjust as needed.
  • Secure the device by applying recommended security settings, enabling encryption for wireless transmissions, and routinely updating firmware via the Monnit management portal.

Frequently asked questions

  • Q: What is the Monnit ALTA Serial MODBUS Gateway used for? A: It serves as a bridge between Monnit’s ALTA wireless sensor network and traditional Modbus devices. As a data concentrator, it aggregates wireless sensor data and exposes it to Modbus masters, enabling integrated monitoring, control, and analytics across hybrid networks.
  • Q: Which interfaces does it support? A: The gateway includes RS-232C and RS-485 serial interfaces to connect Modbus RTU devices and supports wireless ALTA communications on the 900 MHz band for sensors and APN nodes.
  • Q: Can I manage the gateway remotely? A: Yes. The device supports remote management through the Monnit ALTA platform, allowing you to configure, monitor, update firmware, and set alerts from a centralized dashboard.
  • Q: Is the gateway compatible with existing Modbus infrastructure? A: Absolutely. It is designed to interface with common Modbus master devices, PLCs, meters, and other serial-based equipment, enabling you to leverage your installed assets while adding wireless sensor coverage.
  • Q: What kind of deployments is it suited for? A: It is well-suited for industrial environments such as warehouses, manufacturing floors, remote facilities, and campuses where wireless sensors complement legacy Modbus devices to improve monitoring, control, and operational efficiency.
  • Q: How do I install and configure the gateway? A: Begin with physical installation and power, connect serial devices, pair with the ALTA network, set Modbus addressing, and validate through the management portal. Detailed steps are provided in the installation guide and online resources for your site configuration.