Description
Monnit ALTA Wireless 0-20 mA Current Meter - AA Battery Powered
Discover flexible, wireless current sensing with the Monnit ALTA Wireless 0-20 mA Current Meter, a compact, AA battery-powered solution engineered to monitor DC current in the range of 0 to 20 mA. Designed for quick deployment across industrial equipment, sensors, and control devices, this meter captures real-time current data by simply connecting its leads to the positive and ground terminals of the device under test. Perfect for energy management, predictive maintenance, and remote monitoring, it integrates seamlessly with Monnit gateways and cloud dashboards, delivering actionable insights with minimal installation effort. Whether you’re retrofitting an aging system or expanding your IoT-enabled facility, this meter provides dependable visibility into electrical load patterns, enabling smarter decisions that save energy, reduce downtime, and extend equipment life.
- Zero-wires, direct 0-20 mA current measurement: The meter attaches directly to the device under test by connecting to the positive and ground terminals, enabling accurate DC current readings without drafting complex wiring back to a centralized panel. This makes it ideal for retrofits, temporary installations, or hard-to-reach equipment where minimizing disruption is essential. Real-time current data helps you quickly detect abnormal draws, efficiency losses, or intermittent faults, supporting proactive maintenance and operational optimization.
- AA battery-powered for flexible placement: Operated by standard AA cells, this sensor delivers wireless monitoring without the need for a dedicated power outlet. The battery-powered design supports versatile installation options—on or near equipment, inside control cabinets, or in remote locations—while keeping maintenance lightweight and predictable. With a long-lived battery and minimal upkeep, you can deploy this meter in hard-to-power environments and still achieve continuous visibility into current measurements.
- Wireless ALTA connectivity and cloud-ready data: Part of the Monnit ALTA ecosystem, this meter transmits current readings to compatible gateways and the cloud. You gain secure, scalable remote monitoring, real-time dashboards, and historical trends that empower data-driven decisions. Set up alerts for threshold breaches, monitor usage patterns over time, and integrate readings with other Monnit sensors to create a holistic facility monitoring solution that scales with your operation.
- Plug-and-measure installation with simple operation: The installation process is streamlined for speed and reliability. Attach the measurement leads to the device under test, insert fresh AA batteries, and pair the meter with your Monnit gateway using the setup app or portal. Once connected, you’ll begin collecting current data immediately, with signals designed to minimize electrical noise for clear, trustworthy readings that you can depend on for daily operation and long-term analysis.
- Rugged, compact design built for industrial environments: The Monnit ALTA current meter is designed to fit into tight spaces without interfering with equipment. Its compact form and robust construction suit industrial settings where space and reliability matter. Built to withstand the demands of machinery floors and facility environments, this meter delivers durable performance while remaining easy to install, service, and reposition as your monitoring needs evolve.
Technical Details of Monnit ALTA Wireless 0-20 mA Current Meter - AA Battery Powered
- Measurement range: 0-20 mA DC current
- Power source: AA battery powered for wireless operation
- Wireless technology: Monnit ALTA wireless connectivity to compatible gateways
- Data output: Transmits readings to the Monnit cloud dashboard with optional real-time alerts
- Physical form: Compact sensor with two measurement leads for direct connection to the device under test
How to install Monnit ALTA Wireless 0-20 mA Current Meter
- Prepare the device under test: Ensure the equipment is powered down or in a safe state for measurement. Identify the positive and ground terminals where current is to be measured and ready the measurement leads.
- Insert batteries: Open the sensor housing, install a fresh AA battery, and verify the power indicator (if present) confirms power is on. Replace the cover securely to protect the electronics from dust and debris.
- Connect the measurement leads: Attach the meter’s leads to the positive and ground terminals of the device under test according to the wiring instructions. Ensure firm, clean connections to minimize noise and ensure stable readings.
- Pair with a Monnit gateway: Use the Monnit setup app or web portal to pair the meter with a compatible ALTA gateway. Follow the on-screen prompts to add the sensor to your network and assign it to the desired dashboard or group for monitoring.
- Configure monitoring and validation: Once paired, configure data logging intervals, alert thresholds, and dashboard views. Validate measurements by comparing the meter’s readings with a known reference to confirm proper operation and accuracy.
Frequently asked questions
- Q: What does the Monnit ALTA Wireless 0-20 mA Current Meter measure? A: It measures direct current in the 0 to 20 mA range by sensing the current flowing through the connected device’s positive and ground path, providing real-time data that can be stored in the cloud and analyzed over time.
- Q: How does it connect to my monitoring system? A: The sensor uses Monnit ALTA wireless technology to communicate with compatible gateways, which then push data to the Monnit cloud dashboard. This enables remote monitoring, dashboards, and alerts from anywhere with internet access.
- Q: Is this meter suitable for indoor or outdoor use? A: The sensor is designed for industrial environments and is deployed indoors or in controlled environments near equipment. For outdoor or harsh conditions, ensure the device is installed within an appropriate enclosure or following the manufacturer’s recommended mounting guidelines.
- Q: How long will the AA battery last? A: Battery life depends on usage patterns, transmission frequency, and gateway activity. In typical deployments, the battery supports extended operation without frequent replacements, reducing maintenance downtime and labor costs.
- Q: Can I use this meter alongside other Monnit sensors? A: Yes. The ALTA current meter is designed to integrate with the Monnit ecosystem, allowing you to combine it with other sensors (temperature, humidity, flow, etc.) on the same gateway for comprehensive facility monitoring and analytics.
Customer reviews