Monnit ALTA Wireless AC Current Meter Sensor - 20 Amp - AA Battery Powered
The Monnit ALTA Wireless AC Current Meter Sensor is a purpose-built solution for real-time energy monitoring that fits seamlessly into any facility. Designed to measure the RMS current on an AC power line without inline wiring, this 20 amp, AA battery powered device uses a compact current transformer (CT) that simply clamps around the hot conductor of a two-wire (hot, neutral) system. It delivers reliable, continuous data to your Monnit cloud portal, enabling you to track usage, detect anomalies, and optimize electrical efficiency across machines, circuits, and entire rooms. Whether you’re managing a data center, manufacturing floor, school, or office building, ALTA makes it easy to add precise current sensing to your IoT-based facility strategy without the complexity of hardwired sensors.
- Effortless, non-invasive installation. The 20 A AC current meter uses a clamp-on current transformer that wraps around the hot wire. No rewiring or heavy electrical work is required. This makes it ideal for retrofit projects, temporary testing, and ongoing energy audits where quick deployment matters.
- Dedicated battery-powered operation. Powered by a single AA battery, the ALTA sensor delivers wireless data without the need for mains power. This enables placement flexibility across rooms, cabinets, or remote equipment closets where outlets are scarce or unreliable.
- Accurate RMS current with actionable insights. By measuring RMS current through the CT, the sensor provides precise current data that feeds energy dashboards, trend analyses, and performance monitoring. Monitor min/max/current peaks over time to understand load profiles and optimize capacity planning.
- Cloud connectivity for remote monitoring and alerts. Data from the ALTA sensor is transmitted to Monnit’s cloud platform, giving you real-time visibility via dashboards, web portals, and mobile apps. Set up threshold-based alerts to know the moment a circuit spikes or falls below expected levels.
- Versatile use across facilities and applications. Ideal for monitoring critical loads like HVAC, pumps, lighting circuits, production lines, and server racks. The sensor’s compact form factor and battery-powered design suit environments where space is limited or where permanent power provisioning is impractical.
In addition to these features, the Monnit ALTA Wireless AC Current Meter Sensor integrates smoothly with broader energy management workflows. It complements other Monnit wireless sensors to build a complete picture of energy consumption, equipment performance, and occupancy-related load changes. The ALTA sensor is a scalable choice for facilities that want to begin with targeted current monitoring and expand into a full suite of wireless sensors for temperature, humidity, door access, water flow, and more. With robust data collection, organizations can implement data-driven maintenance, optimize peak demand charges, and improve overall electrical safety without disrupting standard operating procedures.
Key benefits include faster on-site deployments, reduced downtime during installation, and the ability to deploy multiple sensors across a single panel or campus. The ALTA device is designed for industrial environments and commercial facilities that require reliable, long-term monitoring without the burden of complex wiring. From energy managers to facilities operations teams, this sensor helps translate raw current readings into meaningful actions—whether that’s adjusting equipment schedules, validating energy-saving initiatives, or supporting compliance reporting.
Technical Details of Monnit ALTA Wireless AC Current Meter Sensor - 20 Amp
- Sensor type: Wireless AC current meter using a current transformer (CT) clamp that surrounds the hot conductor to measure RMS current in a two-wire system.
- Current measurement range: 0–20 A RMS (AC) with high-resolution data suitable for energy analytics and load profiling.
- Power source: Replaceable AA alkaline battery powering wireless operation for flexible placement.
- Wireless communication: Bi-directional wireless transmission to Monnit gateways and the cloud portal; supports remote monitoring from any connected device.
- Data availability: Real-time or interval-based readings with historical logging for trend analysis, peak detection, and anomaly spotting.
- Format and compatibility: Compact, clamp-on design that fits on or near equipment racks, panels, or enclosures; integrates with Monnit’s sensor ecosystem for unified data management.
- Installation method: Non-invasive CT clamp around the hot wire; no cutting required and no interference with the electrical circuit when installed correctly.
- Applications: Ideal for HVAC drives, motors, pumps, lighting circuits, and other critical loads where understanding current draw improves efficiency and safety.
- Alerts and automation: Configurable thresholds and alerting via email, SMS, or mobile app; enables automated responses and proactive maintenance scheduling.
How to install Monnit ALTA Wireless AC Current Meter Sensor
- Prepare and safety check: Ensure the electrical panel or enclosure is accessible and that lockout/tagout procedures are followed if required. Verify there is a suitable place to mount the sensor and that there is no physical damage to the CT clamp or battery compartment.
- Place the current transformer: Open the CT clamp and wrap it around the hot conductor of the circuit you wish to monitor. Ensure the clamp closes securely and the orientation is correct for accurate RMS readings. Do not place the CT around multiple conductors unless the CT is designed for that configuration and your readings require it.
- Install the sensor and power it: Insert a fresh AA battery into the ALTA sensor, then power it on. Allow the device to perform initial self-checks and begin transmitting as soon as it pairs with a gateway or the Monnit portal.
- Pair and configure: Use your Monnit gateway or the cloud portal to pair the sensor. Set up sampling intervals, data refresh rates, and any necessary alerts or thresholds for the monitored circuit. Confirm that the sensor is actively communicating and appears in your device list.
- Verify measurements and calibrate: Check the live readings in the Monnit portal or mobile app. If needed, adjust the sampling rate to balance data granularity with battery life. Validate that min/max/average values reflect the expected load on the monitored circuit.
- Document and expand as needed: Record the installation details, including circuit ID, location, and any naming conventions. Consider adding additional ALTA sensors on other circuits to build a complete energy profile of the facility.
Frequently asked questions
-
Q: What does the Monnit ALTA Wireless AC Current Meter Sensor measure?
A: It measures the RMS current (0–20 A) on AC circuits using a clamp-on current transformer, providing insights into load profiles, peak demands, and energy usage. -
Q: How is the sensor powered?
A: The sensor is AA battery powered, enabling wireless operation without requiring a dedicated power supply or outlet near the installation location. -
Q: Do I need a gateway?
A: In most configurations, yes—data from ALTA sensors is transmitted to Monnit gateways and then to the cloud. The gateway acts as the local collector before cloud delivery. -
Q: Can I monitor multiple circuits with Monnit ALTA?
A: Yes. You can deploy multiple ALTA sensors across different circuits or equipment to build a broader picture of electrical usage in a facility. -
Q: What kinds of alerts can I configure?
A: You can configure threshold-based alerts for current spikes, drops, or abnormal patterns. Alerts can be delivered via email, SMS, or mobile app notifications, enabling rapid response. -
Q: Is installation safe and non-invasive?
A: Yes. The CT clamp is non-invasive and designed for quick, safe installation around the hot wire while maintaining electrical isolation from the sensor itself. Follow standard safety practices and power-down procedures as required.