Description
Monnit ALTA Wireless Differential Air Pressure Sensor - Line Power Only (900 MHz)
The Monnit ALTA Wireless Differential Air Pressure Sensor is engineered for precise, continuous monitoring of pressure differences across two input ports, with seamless wireless transmission to the iMonnit cloud. Designed for industrial environments, this line-powered sensor delivers reliable performance where battery-powered devices may falter—such as HVAC systems, cleanrooms, data centers, and critical process areas. With a focused differential measurement and a straightforward mounting footprint, the ALTA sensor simplifies installation while delivering real-time data, alerts, and historical trends that help optimize performance, efficiency, and safety.
- Real-time differential pressure measurement: The ALTA sensor captures the pressure difference between two input ports, enabling accurate monitoring of ducts, rooms, filtration stages, and process lines. The right inlet port is the negative or low-pressure side when viewed from the top, streamlining wiring and setup for quick integration into existing systems.
- Line-powered reliability: Unlike battery-powered variants, the ALTA operates from line power, providing uninterrupted monitoring suitable for critical HVAC control, cleanroom integrity, and environments where battery replacement would interrupt operations or compromise data continuity.
- Robust wireless connectivity: Utilizing a 900 MHz radio, the ALTA communicates securely with iMonnit gateways and the cloud. This long-range wireless capability reduces wiring complexity across larger facilities and supports scalable monitoring across multiple zones or buildings.
- Cloud-enabled visibility and alerts: With iMonnit integration, you gain instant access to dashboards, real-time readings, historical trends, and configurable alerts. Set thresholds for faults, filter maintenance needs, and receive proactive notifications to prevent downtime or process deviations.
- Simple installation and durable design: The ALTA sensor is built for industrial use with a compact form factor and straightforward mounting options. Its differential input ports accommodate common pressure-sensing connections, making retrofits or new installations efficient with minimal downtime.
Technical Details of Monnit ALTA Wireless Differential Air Pressure Sensor - Line Power Only (900 MHz)
- Model: ALTA Wireless Differential Air Pressure Sensor
- Sensor type: Differential pressure sensor with two input ports for measuring the difference between two pressure points
- Ports: Two input ports; right inlet port functions as the negative or low side when viewed from the top
- Power: Line-powered operation (no battery required)
- Wireless technology: 900 MHz radio for wireless communication
- Connectivity: iMonnit cloud-compatible; data reaches dashboards and alerts via the iMonnit platform
- Mounting and installation: Compact, field-installable design suitable for panel mounting or ductwork integration
- Intended applications: Differential pressure monitoring in HVAC ducts, cleanrooms, laboratories, data centers, and process lines
- Environmental considerations: Built for industrial environments with durable construction designed to withstand typical facility conditions
How to Install Monnit ALTA Wireless Differential Air Pressure Sensor
Installing the ALTA wireless differential air pressure sensor is straightforward and designed to minimize disruption to ongoing operations. Follow these steps to achieve a reliable setup that delivers accurate measurements and robust wireless performance:
- Plan your installation location: Choose a stable, vibration-free area with clean air access to both input ports. Ensure the sensor is mounted where ambient conditions do not exceed its operating range and where the wireless signal can reach the gateway without obstructions.
- Prepare the pressure connections: Identify the two ports on the sensor and prepare the corresponding lines or ducts for connection. Use appropriate fittings to ensure a leak-free seal and avoid introducing contaminants into the sensing ports. Remember that the right inlet is the negative or low side when viewed from the top.
- Connect the pressure lines: Attach the two pressure lines to the corresponding input ports. Use seals or adapters as needed to match your piping or ductwork. Take care to route lines in a manner that minimizes stress on fittings and reduces the risk of vibration or blockage.
- Provide line power: Connect the sensor to the designated power supply that complies with the device’s line-power requirement. Verify voltage and termination according to your facility’s electrical standards. Confirm power stability to prevent intermittent data loss.
- Pair with the gateway and enroll in iMonnit: Power up the sensor and initiate device pairing with your iMonnit gateway. Follow the on-screen prompts or your facility’s standard onboarding process to register the sensor ID, assign it to the correct site or zone, and configure basic data refresh rates.
- Tune defaults and set alerts: After enrollment, review measurement units (e.g., Pa, inH2O, or psi) and set alert thresholds for pressure differentials that warrant attention. Create notification rules to trigger emails or SMS when readings exceed safe or expected ranges.
- Calibrate if needed and test: If your application requires a dry-run calibration, perform any recommended calibration procedure according to your process specifications. Verify readings by comparing with a reference point or a calibrated manometer to confirm accuracy before fully relying on automated alerts.
- Document and secure: Record the installation location, sensor serial number, and gateway association for future maintenance. Ensure all wiring and connections are secured in accordance with safety and electrical standards to prevent accidental disconnection.
Frequently asked questions
- What is differential air pressure? Differential air pressure is the difference in pressure between two separate points. The ALTA sensor measures this difference across its two input ports, enabling monitoring of pressure changes in ducts, rooms, and process lines.
- Does the ALTA require a battery? No. This model is line-powered, providing continuous operation without the need to replace batteries. This makes it ideal for installations where constant monitoring is critical.
- What wireless frequency does it use? The ALTA uses a 900 MHz wireless radio to communicate with iMonnit gateways and the cloud, offering reliable coverage across many facility layouts without relying on a wired network for data transport.
- How does it connect to iMonnit? The sensor pairs with a compatible iMonnit gateway, after which readings are transmitted to the iMonnit cloud. You can access dashboards, set alerts, and review historical trends from any web-enabled device.
- Where should I mount the sensor? Mount the sensor in a location that provides representative differential pressure without exposure to excessive vibration, moisture, or extreme temperatures. Ensure the ports are easily accessible for maintenance and that the lines are secured to prevent kinking or leaks.
- Can I retrofit an existing system? Yes. The ALTA is designed for compatibility with common ductwork and pressure-tapped points. Its two ports support standard differential-pressure sensing connections, facilitating integration into many HVAC, cleanroom, and process monitoring setups.
- What kind of data can I expect to see? Real-time differential pressure readings, historical trends, and configurable alerts. Data is accessible through the iMonnit dashboards, enabling quick insights into system performance and potential issues.
- Is the sensor suitable for industrial environments? Yes. The ALTA is built with a rugged design intended for industrial settings, delivering reliable measurements and durable operation in environments typical of HVAC, laboratories, and data centers.
Customer reviews
Showing - Of Reviews