Monnit ALTA Wireless Water Rope Sensor - Coin Cell Powered

MonnitSKU: 5516901

Price:
Sale price$207.67

Description

Monnit ALTA Wireless Water Rope Sensor - Coin Cell Powered

The Monnit ALTA Wireless Water Rope Sensor is the ultimate solution for proactive leak detection across long, irregular, or hard-to-reach areas. Designed to detect conductive liquids anywhere along a flexible detection rope, this sensor uses two wires embedded in the rope, each coated with conducting polymer. When water or any conductive liquid comes into contact with the rope, the sensor immediately activates its RF radio and transmits data to your Monnit ALTA gateway. This enables real-time alerts, precise leak localization, and rapid response to protect assets, prevent water damage, and minimize downtime. Whether you’re safeguarding data centers, manufacturing floors, laboratories, hospital facilities, or commercial spaces, the ALTA Water Rope Sensor delivers scalable, maintenance-friendly monitoring without the need for extensive wiring or power drops. With its coin cell power source and rugged, adaptable design, you can deploy comprehensive leak detection where traditional sensors can’t easily reach, all while enjoying a seamless integration into the Monnit ALTA ecosystem for dashboards, alerts, and automated workflows.

  • The sensing principle leverages a two-wire rope wrapped in conducting polymer. As soon as moisture or conductive liquid contacts the rope, a completed circuit triggers the ALTA sensor to wake the radio and transmit a detection event. This means you get immediate visibility into leaks along the entire length of the rope, not just at a single point, making it ideal for long runs along floors, around equipment, under trays, or along pipework. With this capability, you can pinpoint the approximate location of a leak and respond quickly, reducing potential damage and downtime. The detection rope is designed to maintain sensitivity across extended spans while remaining robust in industrial environments, providing reliable performance even in busy facilities where spills are common.
  • Coin cell powered operation offers a maintenance-friendly, wireless alternative to wired leak detectors. The compact, battery-powered design minimizes installation complexity—no trenching, wiring, or power drops required. This enables rapid retrofits across existing infrastructure and makes it feasible to deploy in rooms, basements, mezzanines, or exterior areas where electrical outlets are scarce. The energy-efficient architecture helps maximize battery life, so you spend less time replacing batteries while preserving continuous monitoring coverage and consistent alerting across your network.
  • Real-time wireless communication is at the core of the ALTA experience. Upon detecting moisture, the sensor transmits a time-stamped event to the Monnit ALTA gateway, which then delivers the data to the cloud for live dashboards, automated alerts, and historical trending. You can configure threshold-based alerts, hold-down timers, and escalation rules to ensure the right people are informed at the right time. This immediate visibility helps prevent water damage to critical infrastructure, avert safety hazards, and support rapid containment measures—even in remote or hard-to-access locations.
  • Flexible installation options and long-area coverage make this rope-based sensor highly adaptable. The rope can be laid along floors, across thresholds, or around equipment footprints to cover large surface areas and awkward layouts. You can couple multiple rope segments to extend coverage and tailor the sensing path to the exact risk zone. Mounting accessories and simple attachment methods simplify positioning, while the coin cell power design keeps the system clean and cordless, reducing clutter and permitting quick repositioning as your facility layout evolves.
  • Scalable, integrated ecosystem for industrial monitoring. The ALTA Water Rope Sensor is designed to work with the broader Monnit ALTA platform, letting you build a network of sensors—temperature, humidity, gas, and other leak sensors—into a single, unified view. Centralized configuration, secure cloud storage, and role-based access ensure your team can manage deployments across multiple facilities. Whether you’re expanding to cover new production lines or adding additional leak protection around sensitive assets, the ALTA system supports growth without sacrificing reliability or control.

Technical Details of Monnit ALTA Wireless Water Rope Sensor - Coin Cell Powered

  • Power source: Coin cell battery-powered unit designed for maintenance-free operation with long intervals between replacements.
  • Detection method: Two conductors embedded in a sensing rope, both coated with conducting polymer to detect moisture and conductive liquids along the entire rope length.
  • Wireless communication: Monnit ALTA RF technology that transmits detection events to the ALTA gateway and cloud for real-time monitoring and alerting.
  • Coverage and form factor: Flexible rope-based sensor optimized for long spans and awkward layouts; adaptable to various installation environments with a compact sensor module.
  • Environment and durability: Rugged, industrial-grade design suitable for commercial facilities and data centers; intended for reliable operation in typical facility environments where leaks are a concern.

How to install Monnit ALTA Wireless Water Rope Sensor

  • Plan your leak-detection layout by identifying areas most at risk for moisture, standing spills, or fluid contact along floors, around equipment bases, or under trays. Determine the ideal rope path to maximize coverage without creating excessive slack or tripping hazards.
  • Mount or lay the detection rope along the planned path. Use available mounting clips, tapes, or fasteners to secure the rope in place, ensuring it remains in contact with potential fluids and won’t shift during normal operations. For vertical runs, position the rope to minimize sag and maintain full contact with the substrate.
  • Connect the rope ends to the sensing module of the ALTA unit. Verify that the conducting polymer-coated wires are properly seated and that there is no physical damage to the rope that could affect sensitivity. Ensure the rope’s entire length is free of kinks and properly tensioned for consistent detection.
  • Insert a fresh coin cell battery and power on the sensor. Use the Monnit ALTA configuration tools to pair the rope sensor with your ALTA gateway. Confirm that the gateway recognizes the new device and that a secure, bi-directional connection is established.
  • Configure alert rules and test the system. Set water-leak thresholds, alert recipients, and escalation paths in the Monnit dashboard. Validate the setup by applying a small amount of conductive liquid to the rope and confirming an immediate transmission to the gateway and cloud. Fine-tune alerts and run through a live test to ensure accurate localization and reliable notification delivery.

Frequently asked questions

What liquids can the Monnit ALTA Wireless Water Rope Sensor detect?

The system is designed to detect conductive liquids. This includes water with minerals or impurities, coolants, or other fluids that complete a conductive path along the rope. It is not designed to detect non-conductive liquids or liquids that do not create a measurable conductive path.

How long does the battery last in typical use?

Battery life depends on how often the sensor transmits data and how often leaks are detected. The COIN cell-powered design emphasizes low-power operation and maintenance-free usage, with multi-month to multi-year expectations under normal monitoring regimes. Real-world life can vary based on environmental conditions and the frequency of events.

What infrastructure do I need to use this sensor?

The Water Rope Sensor communicates to a Monnit ALTA gateway, which forwards data to the cloud. You’ll need a compatible Monnit ALTA gateway installed at your site and access to the Monnit dashboard to view live data, configure alerts, and manage sensors across facilities.

Can I extend coverage or replace the rope?

Yes. The rope-based design is modular, allowing you to extend coverage by adding additional rope segments or repositioning the rope to align with risk areas. If you need to replace a rope segment, use compatible rope lengths and ensure the ends reconnect properly to maintain consistent sensing throughout the length.

Is professional installation required?

Most installations can be completed by facility staff or technicians familiar with Monnit products. The setup involves laying out the rope, mounting it securely, connecting the ends to the sensor module, inserting a battery, pairing with the gateway, and configuring alerts. For complex layouts or multiple facilities, consider consulting Monnit or an authorized partner to optimize coverage and integration.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like