N1C LR-Series N1C.LR3000 - UPS - 2940 Watt - 3000 VA

N1CSKU: 6347872

Price:
Sale price$1,811.10

Description

Meet the N1C LR-Series N1C.LR3000 UPS, a breakthrough solution for uptime when space is at a premium. This Lithium-Ion powered uninterruptible power supply blends compact design with a modular architecture, delivering reliable power for critical workloads while letting you tailor runtime to your evolving needs. The core UPS module provides up to 2940 watts of continuous output (3000 VA), making it capable of supporting essential servers, storage devices, network gear, and other mission-critical equipment during outages or voltage irregularities. What truly sets the N1C.LR3000 apart is its scalable external battery model: begin with a single battery module and attach up to ten external lithium-ion battery modules to dramatically extend runtime—from hours to days depending on load. This modular approach means you don’t have to oversize or replace the entire system as your workload grows; you simply add capacity when needed, preserving capital and reducing downtime risk. In addition to raw power, the design emphasizes safety, longevity, and energy efficiency, helping you lower total cost of ownership while maintaining a smaller footprint in data centers, edge locations, labs, or SMB environments. The N1C LR-Series is built to endure real-world conditions—delivering stable, clean power with robust protection against common electrical disturbances—so your critical equipment remains operational, even during severe outages or grid fluctuations.

  • Modular Li-Ion Battery System: Start with the UPS module and add up to 10 external Li-ion battery modules to extend runtime dramatically, enabling days of protection for essential systems when needed.
  • High-Capacity Output: 2940 W of continuous power and 3000 VA of apparent power ensure continuity for servers, storage, and networking gear during power interruptions.
  • Compact, Space-Saving Design: Engineered for dense deployments, the LR3000 provides substantial runtime without occupying excessive floor space—ideal for data centers, edge facilities, and labs.
  • Flexible Deployment for Growth: Scales with your business. Expand runtime by adding battery modules rather than replacing the UPS, delivering a future-proof protection solution.
  • Safety, Reliability, and Battery Management: Lithium-ion chemistry with integrated battery management optimizes life, reduces maintenance, and protects equipment from abnormal conditions.

Technical Details of N1C LR-Series N1C.LR3000

  • Output rating: 2940 W / 3000 VA, delivering dependable power for critical loads
  • Battery architecture: external lithium-ion battery modules; supports 1–10 modules for scalable runtime
  • System configuration: UPS module paired with external battery modules to achieve extended runtime and adaptable protection
  • Design philosophy: compact footprint designed to maximize runtime per square foot in data centers, offices, and edge deployments
  • Runtime considerations: actual uptime depends on load size and the number of external battery modules installed; plan based on critical load requirements

How to Install N1C LR3000

Step 1: Choose a suitable installation location. Ensure adequate ventilation, clearance for heat dissipation, and convenient access for maintenance. A rack-mount or flat-surface placement should follow your workspace’s safety and electrical codes.

Step 2: Prepare the input power connection. Use a properly rated circuit and protective devices according to local standards. Route cables to minimize clutter and ensure easy access to the UPS input port.

Step 3: Deploy external Li-ion battery modules. Place modules in an approved enclosure or mounting space and connect them to the UPS as directed in the user manual. Start with the recommended base configuration and add modules in a staged manner to achieve the desired runtime.

Step 4: Connect critical loads to the UPS output. Label cables clearly and confirm proper load distribution. Access the UPS management interface to configure transfer thresholds, alarm notifications, and basic protective settings.

Step 5: Power on and verify operation. Run a self-test to confirm inverter function, battery health, and alert indicators. If any faults appear, consult the manual or contact support before placing the system into production.

Step 6: Establish ongoing maintenance and monitoring. Schedule regular battery health checks, firmware updates for the controller, and routine inspections of cabling and cooling to ensure peak performance over the system’s life.

Frequently asked questions

  • Q: What is the N1C.LR3000's power rating? A: The system provides 2940 W of continuous output, which corresponds to 3000 VA, enabling protection for essential equipment during power events.
  • Q: How many external battery modules can be attached? A: Up to 10 external lithium-ion battery modules can be connected to extend runtime significantly, depending on the workload and number of modules installed.
  • Q: Can I expand runtime without replacing the UPS? A: Yes. The modular design allows you to add external Li-ion battery modules to increase runtime without purchasing a new UPS.
  • Q: Is lithium-ion battery use safe for critical applications? A: The N1C LR-Series employs carefully engineered lithium-ion modules with integrated management and safety protections to support reliable operation in demanding environments.
  • Q: What environments is this UPS best suited for? A: It is well suited for data centers, edge deployments, laboratories, and small to mid-size enterprises where space is limited and uptime is critical.
  • Q: How do I maintain and monitor the battery modules? A: Follow the manufacturer’s maintenance schedule, perform periodic health checks, and use the UPS management interface to monitor module status and alerts.