N1C LR-Series N1C.LR6000 - UPS - 5400 Watt - 6000 VA

N1CSKU: 6347878

Price:
Sale price$2,487.07

Description

The N1C LR6000 is a next‑generation uninterruptible power supply designed for today’s most demanding environments. Part of the LR-Series, it combines a compact footprint with exceptionally long runtime through external lithium‑ion battery modules. Each system includes a robust UPS module and at least one external lithium‑ion battery module, with support for up to 10 modules, unlocking the potential for days of buffered power for critical loads. Built for data centers, healthcare IT rooms, manufacturing floors, and enterprise facilities, the N1C LR6000 delivers reliable power, scalable capacity, and practical flexibility for evolving mission‑critical needs.

  • Long, scalable runtime: Start with a robust UPS module and extend energy storage with up to 10 external lithium‑ion battery modules. This scalable design enables dramatically extended runtime, so essential systems— servers, networking gear, and control systems—stay protected even during extended outages or utility disturbances.
  • Lithium‑ion technology for efficiency and longevity: The LR6000 leverages lithium‑ion energy storage to deliver higher energy density in a lighter package, faster recharge, and a longer cycle life compared with traditional lead‑acid options. This translates into reduced maintenance costs, less weight on site, and improved total cost of ownership over the life of the system.
  • Modular, future‑proof architecture: With its modular external battery approach, the N1C LR6000 is designed to grow with your business. Add or remove battery modules to match changing workloads and power strategies, ensuring you optimize capital expenditure while preserving uptime for critical assets.
  • Compact footprint for constrained spaces: Despite handling high power, the LR6000 is engineered to fit smaller data closets, server rooms, and equipment racks where space is at a premium. Its compact form factor helps you consolidate power protection without sacrificing room to grow.
  • Reliable protection for critical loads: The N1C LR6000 protects sensitive equipment from power disturbances, extends the availability of IT and facility systems, and maintains power quality during outages or irregular utility conditions. This reliability is essential for minimizing downtime and preserving data integrity in demanding environments.

Technical Details of N1C LR6000

  • Model: N1C LR-Series N1C.LR6000
  • Power rating: 5400 Watts (W) / 6000 Volt‑Amps (VA)
  • Battery system: External lithium‑ion battery modules; supports up to 10 modules
  • Topology: Lithium‑ion UPS with modular external battery support
  • Applications: Suitable for data centers, telecom rooms, healthcare IT, and other mission‑critical facilities

How to install N1C LR6000

Step 1: Plan and prepare – Select a location with adequate ventilation, stable mounting, and sufficient clearance for service access and battery module connections. Confirm electrical room compliance and ensure the environment meets safety requirements for lithium‑ion systems.

Step 2: Install the UPS module – Place or rack‑mount the UPS module in its designated position. Connect it to the appropriate mains supply per local electrical codes, using proper grounding and protection devices. Verify that the UPS enclosure and connectors align with the installation plan before proceeding.

Step 3: Attach external battery modules – Begin with at least one external lithium‑ion battery module. Use the manufacturer’s connection diagram to securely link each module to the UPS, then add additional modules up to the maximum supported count (up to 10 total). Ensure all connectors are clean, dry, and firmly seated to prevent arcing or loose contacts.

Step 4: Power up and configure – Power on the UPS and access the management interface or onboard display to verify system health. Configure critical settings such as alarm thresholds, notification contacts, and runtime targets. If available, set up any automatic testing or reporting schedules to support ongoing monitoring.

Step 5: Commission the system – Perform a controlled load test to validate transfer times, battery health indicators, and overall uptime performance. Observe the interaction between the UPS and external battery modules, and confirm that software alerts and logging are functioning as intended. Document results for facility maintenance records.

Frequently asked questions

Q: What does 5400 W / 6000 VA mean for my loads?
A: 5400 W represents the real power the UPS can deliver to connected equipment, while 6000 VA reflects the apparent power capacity. The actual runtime depends on the load profile and the number of external battery modules installed.

Q: How many external battery modules can the N1C LR6000 support?
A: The system supports up to 10 external lithium‑ion battery modules, allowing you to scale runtime to meet the needs of your mission‑critical workloads.

Q: Is lithium‑ion a good fit for long‑term data protection?
A: Lithium‑ion batteries offer compact energy density, longer cycle life, and faster recharge times, which can improve maintenance intervals and reduce total cost of ownership when compared with traditional battery chemistries in appropriate UPS applications.

Q: Can I expand my capacity later?
A: Yes. The LR6000’s modular design is intended to grow with your facility. You can add battery modules over time as workloads change, without replacing the core UPS unit.

Q: What kind of maintenance is required?
A: Regular inspection of battery connections and cabinet integrity is advised. Follow the manufacturer’s maintenance schedule, observe safety precautions when handling external modules, and keep firmware or software up to date if management features are available.