Description
Opengear EMD5780 - Water Leak Detector
The Opengear EMD5780 Water Leak Detector is a critical safeguard for IT environments, data centers, and enterprise server rooms. Engineered to provide fast, reliable moisture detection, this compact sensor system helps IT teams protect valuable equipment, prevent costly downtime, and maintain business continuity. With its multi-point sensing capability and seamless integration into Opengear’s management ecosystem, the EMD5780 empowers administrators to detect leaks early, trigger rapid responses, and maintain a resilient infrastructure. Whether you’re safeguarding under raised floors, behind racks, or around air conditioning units, the EMD5780 is designed to deliver real-time visibility into potential water intrusion before it compromises critical systems. This detector is ideal for data centers, colocation facilities, telecom closets, and any environment where even a small leak can escalate into a major disruption. By combining precise moisture sensing with centralized alerting, the EMD5780 helps facilities teams act decisively, reduce risk, and extend the life of expensive equipment.
- Real-time water detection and rapid alerting: The EMD5780 continuously monitors for the presence of water at sensor points and immediately notifies your Opengear management console and preferred alert channels. In environments where every second counts, real-time notifications enable swift action—from shutting down affected power sources to dispatching on-site responders—minimizing the potential for equipment damage and downtime.
- Flexible sensor coverage for high-risk areas: Designed to protect critical zones such as under raised floors, behind racks, along cable trenches, and near cooling units, the EMD5780 supports a network of moisture detection pads that can be strategically placed around the perimeter of equipment and infrastructure. This flexible layout ensures comprehensive coverage of leak-prone hotspots, giving you confidence that no moisture goes undetected.
- Seamless integration with Opengear management platform: The EMD5780 is built to work within Opengear’s unified management and monitoring ecosystem. It delivers alerts through the same channels you rely on for other critical infrastructure events (SNMP traps, email, dashboards, and syslog, depending on your configuration). This integration makes it easier to correlate water events with power, environmental sensors, and network status, providing a holistic view of your data center health.
- Durable, reliable design for data centers and server rooms: Engineered for harsh IT environments, the EMD5780 is built to withstand the everyday challenges of a data center, telecom closet, or remote site. Its compact footprint fits easily into tight spaces, while robust construction helps ensure consistent operation even in environments with dust, vibration, and temperature variations commonly found near cooling systems and equipment racks.
- Easy installation and low maintenance: The Opengear EMD5780 emphasizes a straightforward setup with plug-and-play sensibility and simple sensor placement. Once installed, it requires minimal ongoing maintenance—sensor pads can be replaced as needed, and alert configurations can be updated quickly to reflect changes in your facility layout. This makes it suitable for teams of all sizes, from small remote offices to large enterprise data centers.
Technical Details of Opengear EMD5780
- UPC/SKU reference: Please consult the official Opengear/Synnex product listings for exact UPC and SKU details.
- Sensor technology: Moisture/Water detection pads designed for multi-point monitoring around critical equipment.
- Communication: Integrated with Opengear management platform to deliver real-time alerts via standard channels (e.g., SNMP traps, email, dashboards).
- Target applications: Data centers, server rooms, telecom closets, and other IT environments where water leaks can threaten equipment and uptime.
- Enclosure and mounting: Compact, rack-friendly footprint suitable for tight spaces near racks and under raised floors.
- Power considerations: Designed to operate within typical data center power and management environments; details on power options provided in official product documentation.
How to Install Opengear EMD5780
- Plan placement carefully: Before installation, map out high-risk zones where leaks are most likely to occur—under raised floors, near cooling units, around water-cooled equipment, and adjacent to pipes or condensate lines. Create a layout that maximizes sensor coverage without obstructing airflow or cable pathways.
- Mount sensors and sensors pads: Secure moisture detection pads at strategic locations using the included mounting hardware. Ensure pads are in direct contact with the floor or surface where water intrusion is most probable. Clear any debris and avoid placing sensors where standing water is unlikely to reach, as placement quality directly influences detection reliability.
- Connect to Opengear management: Integrate the EMD5780 with your Opengear devices according to the installation guide. Establish communication with the central management console to enable real-time data flow, event correlation, and alert routing. Verify that the detector appears in the Opengear inventory and is ready to transmit alarms.
- Power up and validate: Power the unit and verify that status indicators show normal operation. Run a controlled test to confirm that moisture is detected as intended and that alerts propagate through your configured channels (dashboard, email, SNMP traps). Address any fault indicators promptly to ensure ongoing reliability.
- Configure alerts and monitoring policies: Define alert thresholds, notification recipients, and escalation policies. Customize dashboards to reflect the water-leak risk profile of each area, and set up automated responses where possible (e.g., triggers to trigger a cooling shutdown or lift-and-shift of sensitive equipment when a leak is detected).
- Maintenance plan: Establish a routine for inspecting sensor pads, replacing damaged units, and updating firmware or configuration as your facility layout evolves. Document sensor locations and access paths for quick maintenance or future expansions, ensuring long-term effectiveness of your water-leak defense.
Frequently Asked Questions
-
Q: What does the Opengear EMD5780 protect?
A: The EMD5780 protects IT infrastructure from water intrusion in data centers, server rooms, and other critical facilities. By detecting moisture early and delivering rapid alerts, it helps prevent equipment damage, downtime, and costly repairs. -
Q: How are alerts delivered?
A: Alerts are delivered through Opengear’s management platform and can be routed to standard channels such as SNMP traps, email, dashboards, and syslog, depending on your configuration. This centralized approach allows teams to respond quickly and coordinate remediation efforts. -
Q: Can I install the EMD5780 by myself?
A: Yes. The EMD5780 is designed for straightforward installation in data-center-ready environments. Follow the placement guidelines, mount the sensors correctly, connect to the Opengear device, power up, and configure alarms. Ensure you document sensor locations for future maintenance. -
Q: Is the EMD5780 suitable for all environments?
A: The EMD5780 is intended for IT environments that require moisture detection, including data centers, server rooms, telecom closets, and similar facilities. Always assess your specific site conditions—such as humidity, floor type, and ventilation—to optimize sensor placement and alerting policies. -
Q: What maintenance is required?
A: Regular checks should include inspecting sensor pads for wear or damage, replacing worn components, and updating firmware or configuration as needed. Periodic tests should be performed to verify that detection and alerting work correctly, especially after any infrastructure changes.
Customer reviews