Panduit 72V Lead Acid Battery Cartridge 3kVA UPS

PanduitSKU: 12742779

Price:
Sale price$522.16

Description

Panduit 72V Lead Acid Battery Cartridge 3kVA UPS

Ensure uninterrupted power for critical equipment with the Panduit 72V Lead Acid Battery Cartridge designed for 3kVA UPS installations. This valve-regulated, lead-acid battery module delivers a dependable, steady 72 V DC supply, optimized for reliable backup performance in data centers, telecom rooms, and industrial environments. Engineered for low maintenance and safe operation, the VRLA battery cartridge is designed to slot into standard UPS configurations, delivering predictable runtime and minimal service interruptions. Whether you’re safeguarding servers, storage arrays, networking gear, or essential medical devices, this battery cartridge provides the stability and resilience your uptime-sensitive systems demand.

  • Reliability and performance: The 72V lead‑acid cartridge uses Valve-Regulated Lead-Acid (VRLA) chemistry to minimize gas emission, enabling safe, sealed operation in cabinet and rack environments. It delivers a steady DC output to support 3kVA UPS systems, helping you maintain clean startup power, stable voltage under load, and dependable discharge protection during outages.
  • Low maintenance and safety: This VRLA battery is designed for minimal upkeep with a sealed, spill‑proof enclosure. No routine water topping is required, reducing maintenance overhead and the risk of acid exposure. The enclosure and mounting design emphasize safety in crowded data centers and busy telecom rooms while simplifying replacement during maintenance windows.
  • Compatibility and UPS integration: Specifically engineered for 3kVA UPS platforms, the Panduit battery cartridge integrates with standard UPS battery interfaces and mounting schemes. Its 72 V DC configuration ensures consistent compatibility with UPS architectures that demand a reliable high-voltage, low‑current battery source for extended runtimes and rapid recovery after discharge.
  • Compact design, extended lifecycle: The cartridge form factor is optimized for tight spaces, enabling faster swaps and minimal downtime. The sealed VRLA design contributes to a longer service life under proper charging, temperature control, and routine UPS maintenance, helping lower total cost of ownership over the life of the UPS.
  • Applications and key benefits: Ideal for data centers, edge computing sites, hospitals, call centers, and industrial facilities. By delivering dependable 72V DC backup to a 3kVA UPS, it protects critical workloads, preserves data integrity, and supports business continuity during power interruptions while reducing maintenance and replacement complexities.

Technical Details of Panduit 72V Lead Acid Battery Cartridge 3kVA UPS

  • Voltage: 72 V DC
  • Chemistry: Valve-Regulated Lead-Acid (VRLA) Battery
  • Battery type: Lead Acid, sealed and spill-safe
  • Configuration: Battery cartridge designed for 3kVA UPS systems
  • Maintenance: Low maintenance; no routine water top-up required under normal use
  • Safety: Sealed enclosure with venting per safety standards to manage gas buildup
  • Installation environment: Suited for indoor data centers, telecom rooms, and industrial cabinets
  • Lifecycle considerations: Optimized for long service life with proper charging and temperature control

How to install Panduit 72V Lead Acid Battery Cartridge 3kVA UPS

  • Power down the UPS and disconnect the input power source following your site safety procedures. Ensure you are wearing appropriate PPE and adhering to lockout/tagout guidelines.
  • Verify compatibility between the 72V lead-acid battery cartridge and your 3kVA UPS model. Confirm connector types, mounting brackets, and space within the UPS bay.
  • Prepare the installation area: clear the rack or cabinet space, inspect the mounting rails, and verify that the battery cartridge packaging is intact and free of damage.
  • Remove the existing cartridge (if replacing) and align the new Panduit battery cartridge with the UPS chassis. Slide into place until the locking mechanism engages and the cartridge is securely seated.
  • Connect the electrical terminals according to the UPS wiring diagram. Re-seat any interlock connectors and confirm a firm, clean connection on both input and output terminals.
  • Restore power to the UPS and perform a self-test or diagnostic run. Check for proper voltage, no fault alarms, and a normal battery health status. Validate a brief load test to ensure stable output.
  • Document the installation, log any fault codes, and dispose of the old cartridge according to local environmental regulations and vendor guidelines.

Frequently asked questions

  • Q: What is the voltage and chemistry of this battery cartridge? A: It is a 72 V DC lead-acid battery cartridge using Valve-Regulated Lead-Acid (VRLA) chemistry designed for 3kVA UPS systems.
  • Q: Is this battery cartridge maintenance-free? A: Yes. The VRLA design is sealed and requires minimal maintenance. No routine water topping is needed under normal operation.
  • Q: Which UPS models is it compatible with? A: It is designed for Panduit 3kVA UPS platforms and other UPS systems that accept a 72V VRLA cartridge. Always verify model compatibility with your specific UPS.
  • Q: What factors influence runtime? A: Runtime depends on the UPS load, battery health, temperature, and charging regime. The cartridge provides the necessary reserve power for the supported 3kVA UPS and connected devices.
  • Q: How should I dispose of the old battery cartridge? A: Follow local regulations for lead-acid battery disposal. Return the old cartridge to a licensed recycling program, vendor take-back, or appropriate waste facility.