Description
Engineered to keep top-entry cabling from leaking hot air back into the cabinet, the Panduit Cool Boot Cabinet Top Air Sealing Fitting provides a premium, airtight seal for 3" x 5" cabinet top openings. This fit-for-purpose accessory uses airtight fabric and the innovative Ultra-Cinch™ Tie to close the top of the fabric tightly, dramatically reducing hot air bypass around cables. The result is enhanced cooling efficiency for network equipment, more stable performance, and potential energy savings in data center or equipment room environments. Designed for use with popular cabinet widths of 700mm, 800mm, and 1000mm, it blends seamlessly with existing Panduit cable management ecosystems and is built for long-term reliability in demanding installations.
- Tight-seal technology: The airtight fabric and Ultra-Cinch™ Tie create a secure, leak-free seal at the top of the cabinet. This design minimizes hot air bypass around cables and prevents recirculation of warm air into the equipment chamber, helping maintain cooler operating temperatures for switches, routers, servers, and other critical hardware.
- Energy-efficient cooling: By reducing the amount of heated air that escapes through cabinet top openings, the Cool Boot supports more efficient cooling strategies. In turn, this can contribute to lower chiller or cooling system workload and help curb energy costs, particularly in densely populated equipment rooms or racks with high cable density.
- Cable-friendly, maintenance-friendly design: The boot is purpose-built to accommodate multiple cables routed through the cabinet top while preserving a tight seal around them. The fabric is durable and easy to clean, and the Ultra-Cinch™ mechanism enables quick tightening or release, simplifying maintenance and reconfiguration without sacrificing performance.
- Unified compatibility with common cabinet sizes: Specifically designed for use with cabinets that are 700mm, 800mm, and 1000mm wide, ensuring a proper fit within widely adopted rack standards. This compatibility reduces the need for adapters and makes it straightforward to upgrade or expand existing infrastructure without sacrificing top-seal performance.
- Easy deployment, robust performance: The installation process is straightforward and requires minimal downtime. Once installed, the seal remains resilient against environmental changes and cable movement, delivering consistent performance over time even in busy data centers or network closets.
Technical Details of Panduit Cool Boot Cabinet Top Air Sealing Fitting
- Seals off 3" x 5" cabinet top openings when cables are routed through the top of a cabinet.
- Airtight fabric combined with Ultra-Cinch™ Tie to close the top of the fabric, minimizing hot air bypass.
- Designed to improve cooling of network equipment and reduce energy costs by limiting heat recirculation.
- Compatible with cabinet widths of 700mm, 800mm, and 1000mm.
- Optimized for use with top-entry cable routing to maintain a clean, controlled airflow within the cabinet.
How to install Panduit Cool Boot Cabinet Top Air Sealing Fitting
Follow these straightforward steps to install the Panduit Cool Boot Cabinet Top Air Sealing Fitting and start enjoying improved cooling efficiency and energy savings. The process is designed to be quick, minimizing downtime while delivering a secure seal that resists movement and maintains performance under typical operating conditions.
- 1) Inspect the cabinet top opening to confirm it is a 3" x 5" opening and that the surrounding surface is clean and free of debris. Prepare the top entry area by removing any obstructions that could interfere with the boot’s seal or cable routing.
- 2) Position the Cool Boot so that the airtight fabric covers the 3" x 5" top opening, ensuring that the Ultra-Cinch™ Tie is accessible and can be tightened around the fabric edge for a snug fit.
- 3) Begin tightening the Ultra-Cinch™ Tie, drawing the fabric securely closed around the cables. Apply steady, even tension to create a tight seal without pinching cables or causing damage to the jacket or connectors.
- 4) Route cables through the top opening as needed. After placement, re-check the seal around all cables to ensure there are no gaps or loose portions that could permit air leakage; readjust the cinch as necessary.
- 5) Verify airflow and cooling performance after installation. If your rack includes additional seal components or venting accessories, test the combined effect to confirm optimal cooling and energy efficiency gains across the cabinet.
Frequently asked questions
-
Q: What size cabinet top opening does the Panduit Cool Boot seal?
A: It is designed to seal 3" x 5" cabinet top openings, making it ideal for top-entry cable routing while maintaining a robust seal. -
Q: Which cabinet widths are compatible with this fitting?
A: The Cool Boot is intended for use with cabinets that are 700mm, 800mm, and 1000mm wide, aligning with common data center and equipment room configurations. -
Q: How does this product impact cooling and energy costs?
A: By minimizing hot air bypass around cables at the cabinet top, the seal supports more effective cooling of network equipment and can contribute to reduced energy costs through improved system efficiency. Real-world savings depend on factors such as rack density, ambient conditions, and existing cooling infrastructure. -
Q: Is the fabric reusable and easy to maintain?
A: Yes. The airtight fabric is designed for durable use, and the Ultra-Cinch™ Tie allows for repeated tightening and release as cables are added or rearranged, with cleaning and maintenance straightforward to perform in standard data center environments. -
Q: How easy is installation and does it require downtime?
A: Installation is quick and straightforward, typically enabling a minimal downtime window. The fit is designed to stay secure during normal operation and cable movements, reducing the need for frequent adjustments.