Panduit FiberRunner FR6ACAB Mounting Bracket
The Panduit FiberRunner FR6ACAB Mounting Bracket is a robust top-of-cabinet solution designed to support 6x4 and 4x4 FiberRunner systems with precise alignment. Engineered to adapt to varying cabinet heights, this bracket enables level cable runs and clean spillouts, helping data centers, network closets, and enterprise server rooms maintain orderly, scalable fiber management. With the FR6ACAB, you gain a reliable mounting method that simplifies installation, speeds up maintenance, and minimizes cable clutter, all while preserving the performance and organization of your FiberRunner network infrastructure.
- Supports 6x4 and 4x4 FiberRunner configurations, providing a unified mounting solution for common cabinet-top installations.
- Adjustable length from 4 1/4" (108 mm) to 9" (229 mm), enabling precise leveling of runs over uneven cabinet heights.
- Allows spillouts such as vertical tees to be positioned directly over cabinet-top cable inlets for clean, efficient routing.
- Designed for secure attachment to cabinet tops to maintain consistent cable paths and reduce movement or misalignment during service.
- Streamlined installation supports fast deployment in dense fiber environments, improving overall data-center uptime and maintenance efficiency.
Technical Details of Panduit FiberRunner FR6ACAB Mounting Bracket
- Compatibility: Supports Panduit FiberRunner 6x4 and 4x4 systems when mounted to the top of equipment cabinets.
- Adjustability: Extends from 4 1/4" (108 mm) to 9" (229 mm) to accommodate uneven cabinet heights and ensure level cable runs.
- Cable Routing: Enables spillouts, such as the vertical tee, to be positioned directly over cabinet-top cable inlets for efficient cable management.
- Mounting Surface: Specifically designed for secure attachment to the top surface of cabinets, improving stability of the FiberRunner pathway.
- Design Focus: Provides a streamlined, space-efficient mounting solution that integrates smoothly with existing FiberRunner components for scalable deployment.
How to install Panduit FiberRunner FR6ACAB Mounting Bracket
- Before you start, verify you have the FR6ACAB bracket and the appropriate fasteners for your cabinet material and mounting surface. Prepare the workspace and ensure power to nearby equipment is safely managed.
- Position the bracket on the top of the cabinet where you plan to route the FiberRunner runs. Use a measuring tape to determine the desired extension within the 4 1/4" to 9" (108–229 mm) range for level alignment.
- Adjust the bracket to the required length by extending or retracting the mounting arm until the top edge is aligned with adjacent cable pathways and cabinet inlets.
- Secure the bracket to the cabinet top using the appropriate fasteners for your cabinet construction. Ensure the bracket is firmly anchored and level to prevent movement during cable installation or maintenance.
- Attach the FiberRunner channels onto the bracket per Panduit’s installation guidelines. Route 6x4 or 4x4 FiberRunner runs along the bracket, aligning spillouts and tees with cabinet-top inlets to achieve a clean, direct path for fiber cables.
- Check the alignment and bend-radius clearances of all cables. Make any final adjustments to the bracket extension to maintain tidy runs and minimize strain on cables.
Frequently asked questions
- Q: What FiberRunner configurations does the FR6ACAB bracket support? A: It is designed to support the 6x4 and 4x4 FiberRunner systems when mounted to the top of cabinets.
- Q: How adjustable is the FR6ACAB bracket? A: The bracket adjusts from 4 1/4" (108 mm) to 9" (229 mm), allowing precise leveling of runs over uneven cabinet heights.
- Q: Can spillouts be positioned over cabinet inlets? A: Yes, the design accommodates spillouts such as vertical tees to sit directly over cabinet-top cable inlets for efficient routing.
- Q: Is the FR6ACAB a quick-install solution? A: It is intended to streamline top-of-cabinet mounting with compatible FiberRunner components, helping reduce installation time and downtime in busy environments. Always follow your facility’s mounting standards and safety procedures during installation.