Panduit P08D10M Horizontal Intelligent Power Distribution Unit

PanduitSKU: 12752497

Price:
Sale price$952.14

Description

Panduit P08D10M Horizontal Intelligent Power Distribution Unit

The Panduit P08D10M Horizontal Intelligent Power Distribution Unit (iPDU) is a next‑generation power management solution that goes beyond simple outlets. Part of the SmartZone G5 family, this horizontal iPDU delivers precise power distribution, integrated energy metering, and vigilant environmental monitoring right at the rack or cabinet level. Built for data centers, edge deployments, and high‑density server rooms, the P08D10M provides actionable insights, helping facilities optimize power usage, reduce risk, and enhance uptime through proactive monitoring and control. With its scalable design and enterprise‑grade reliability, this iPDU is a cornerstone for modern IT infrastructure where every watt and sensor matters.

  • Comprehensive power distribution and metering: The P08D10M doesn’t just route power; it measures it with accuracy. Each outlet or circuit can be monitored for real‑time energy consumption, allowing operators to track usage, identify power hogs, and allocate energy costs precisely. This level of visibility supports power‑aware IT planning, capacity management, and informed decisions that drive improvements in PUE. The built‑in metering combines voltage, current, and power factor data to deliver a complete picture of how the rack is drawing power under varying workloads.
  • Intelligent overload protection and proactive alerts: Continuous monitoring scans for electrical overloads, abnormal loads, and fault conditions. When thresholds are exceeded or anomalies are detected, the iPDU sends rapid alerts to central monitoring dashboards, SNMP traps, or APIs, enabling staff to respond before outages occur. This proactive approach minimizes risk to critical devices and reduces incident response time, contributing to higher availability and smoother maintenance windows.
  • Rack‑level environmental sensing for safer IT environments: In addition to power, the P08D10M monitors environmental factors that influence hardware longevity. Temperature and humidity sensors at the rack level help operators maintain stable conditions and prevent thermal throttling or condensation. With environmental data integrated into the SmartZone G5 platform, IT teams gain a holistic view of how power and climate interact within each rack, enabling targeted cooling strategies and more reliable equipment performance.
  • Remote management, automation, and scalable control: The iPDU is designed for modern data centers that rely on centralized control. It syncs with Panduit SmartZone G5 for remote configuration, policy enforcement, and automation workflows via APIs. Administrators can push firmware updates, adjust outlet policies, set alert thresholds, and orchestrate power‑related tasks across multiple racks from a single pane of glass. This remote capability reduces on‑site visits, accelerates incident response, and supports scalable, zero‑touch deployments.
  • Space‑efficient, flexible horizontal design for standard racks: Engineered to fit the common 19‑inch rack, the horizontal form factor preserves valuable rack space while delivering robust power management. The compact profile simplifies cabling, improves airflow, and integrates neatly into existing infrastructure without forcing reconfiguration. The P08D10M is designed to complement other Panduit solutions, enabling a cohesive, modular approach to data center power and environmental management.

Technical Details of Panduit P08D10M Horizontal Intelligent Power Distribution Unit

  • Model family: Panduit P08D10M Horizontal iPDU, part of the SmartZone G5 ecosystem for integrated energy management and environmental sensing.
  • Metering capabilities: Built‑in energy metering for per‑circuit and total power data, with time‑based trends to support usage analytics and capacity planning.
  • Environmental sensing: Rack‑level temperature and humidity monitoring options to help maintain safe operating conditions and prevent thermal events.
  • Management interface: Compatible with SmartZone G5 for centralized monitoring, alerting, and automation; supports API access for integration with ITSM and monitoring platforms.
  • Safety and compliance: Designed to meet industry standards for data center power distribution and environmental monitoring, enabling reliable performance in demanding environments.
  • Scalability: Modular design supports scalable deployment across multiple racks, helping data centers grow without sacrificing visibility or control.

how to install Panduit P08D10M Horizontal Intelligent Power Distribution Unit

Installing the Panduit P08D10M is a structured process designed for standard 19‑inch racks and data center environments. Begin with a careful planning phase to determine the number of outlets or circuits required, the desired metering granularity, and which environmental sensors will be deployed. Confirm the rack location, ensure adequate clearance for airflow, and verify power source availability to match the unit’s configuration. Mount the iPDU securely in the rack using the supplied mounting hardware, aligning it with other equipment to maintain clean cabling paths and optimal cooling airflow.

With the unit physically mounted, proceed to wiring and wiring management. Connect incoming mains power following local electrical codes, ensuring proper grounding and color coding. Route outlet and sensor cables to minimize cross‑traffic and avoid obstructing airflow around heat‑generating devices. Attach any optional environmental sensors at the designated rack locations and connect them to the iPDU as directed in the installation guide.

Power up and begin configuration through the SmartZone G5 management interface. Establish device credentials, enable energy metering, and set threshold values for power usage and environmental parameters. Configure alert channels (email, SNMP, or API endpoints) so that operations teams receive timely notifications. Create automation rules to respond to events—for example, triggering cooling or workload distribution actions when temperature rises beyond safe levels.

Finally, validate operation by running a short test: simulate load changes, review live metering data, and confirm that alarms trigger as expected. Verify that environmental readings correlate with observed rack conditions and that remote management access is functioning properly. Document the configuration for future audits and scale the deployment by replicating the steps across additional racks as your data center grows. Regularly review metering trends and alert thresholds to maintain peak efficiency and reliability over time.

Frequently asked questions

  • What exactly is a horizontal iPDU, and how does the Panduit P08D10M fit into a data center?
    A horizontal iPDU is a power distribution unit designed to mount flat in a rack, occupying space across the width rather than the height. The Panduit P08D10M fits standard 19‑inch racks and provides not only power distribution but also real‑time energy metering and environmental sensing. This combination supports precise capacity planning, improved energy efficiency, and better IT asset protection, making it a strong choice for data centers seeking enhanced visibility and control at the rack level.
  • How does the built‑in metering help with energy optimization?
    The metering capability captures voltage, current, and power data for individual outlets and circuits, enabling detailed usage analytics and trend analysis. This visibility helps IT and facilities teams identify underutilized or overburdened circuits, optimize workload placement, and implement targeted efficiency initiatives to lower overall energy consumption and improve PUE.
  • Can the iPDU be managed remotely?
    Yes. The P08D10M is designed to integrate with the SmartZone G5 platform, allowing remote monitoring, configuration, alerting, and automation. Remote management reduces the need for on‑site visits, speeds incident response, and supports scalable operations across multiple racks and sites.
  • What kind of environmental monitoring does it provide?
    In addition to electrical data, the iPDU can monitor rack‑level temperature and humidity (where options are installed). This environmental visibility helps prevent thermal issues, protect equipment, and guide cooling strategies within the data center, ensuring reliable operation of critical IT gear.
  • Where can I find the exact specifications for different SKUs?
    Exact specifications vary by model and SKU. Refer to the Panduit official datasheet and product documentation for P08D10M configurations, and, if needed for procurement, consult the specifications section on ec.synnex.com using the relevant UPC or SKU as a reference.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like