The Panduit SmartZone G5 iPDU is not just a power distribution unit; it is an intelligent, rack-level energy management and environmental sensing solution designed to maximize data center uptime, efficiency, and visibility. The P08E18M model combines robust electrical distribution with real-time metering, proactive alerts, and integrated environmental monitoring to help data center managers optimize capacity planning, reduce energy waste, and maintain safe operating conditions for critical IT equipment. With its horizontal, 19-inch rack-mount form factor and scalable architecture, this iPDU fits seamlessly into modern data centers, edge deployments, and high-density IT environments. By continuously scanning electrical circuits for overloads and monitoring environmental variables such as temperature and humidity, the Panduit iPDU provides actionable insights through an intuitive interface and integration-ready management protocols. It’s a trusted solution for facilities that demand reliability, precision, and proactive control over power distribution and environmental health.

  • Real-time power monitoring and energy management: The P08E18M offers comprehensive outlet-level and total power metering, capturing voltage, current, active power, energy consumption, and power factor. This enables precise usage reporting, capacity planning, and demand forecasting. With historical trending and live dashboards, you can identify energy hotspots, optimize load balancing, and implement targeted efficiency initiatives without guessing where losses occur.
  • Integrated environmental sensing for rack health: Beyond power, this iPDU continuously monitors environmental conditions within the rack such as temperature and humidity, enabling early detection of cooling inefficiencies or hotspots. Proactive alerts help prevent thermal-related incidents that can jeopardize equipment reliability, ensuring your servers and storage devices operate within safe thermal envelopes.
  • Advanced safety, overload protection, and control: The unit provides circuit overload detection and protective controls to help safeguard critical IT loads. With configurable thresholds and automatic shutdown or selective power cycling at the outlet level, you gain granular control over risk mitigation while maintaining uptime for essential services.
  • Seamless management and DCIM integration: Designed for modern data centers, the iPDU supports web-based management, SNMP, and API-driven integration for DCIM platforms. Live dashboards, alerting, and event logs simplify administration and enable central visibility across multiple racks, rows, or pods with consistent policy enforcement.
  • Flexible installation and scalable architecture: The horizontal 19-inch rack-mount form factor is ideal for dense deployments where space efficiency matters. Modular design and cable-management features help reduce clutter and improve airflow, while easy-to-reconfigure outlets and banks support evolving IT infrastructure without disruptive rewiring.

Technical Details of Panduit P08E18M Horizontal Intelligent Power Distribution Unit

  • Model and family: P08E18M in the Panduit SmartZone G5 iPDU family, designed for horizontal rack integration with intelligent power distribution and environmental sensing capabilities.
  • Rack compatibility: 19-inch rack-mountable footprint, horizontal orientation suitable for deployment in data center cabinets and tall racks where space efficiency and front-access monitoring are required.
  • Power input and electrical context: Universal input range designed to accommodate common data center power supplies. Compatible with single-phase power across standard data center voltages and frequencies; supports robust electrical distribution with per-outlet visibility.
  • Metering and monitoring: Real-time, per-outlet and aggregate metering for voltage, current, active power (kW), energy (kWh), and power factor. Includes data logging, time-stamped events, and trend analysis to drive energy-aware operations and capacity planning.
  • Environmental sensors: Built-in environmental monitoring for rack temperature and humidity; optional/extendable sensors for additional environmental variables where supported by SKU and integration framework.
  • Communication and management: Ethernet connectivity with standard management protocols (e.g., web interface, SNMP, API access) to enable remote monitoring, alerting, and integration with DCIM, ITSM, and network management systems.
  • Alerting and notifications: Configurable thresholds with proactive alerts delivered via email, SNMP traps, or push notifications as supported by the management platform. Enables rapid response to abnormal power or environmental conditions.
  • Outlets and distribution: Configurable outlet banks designed to accommodate varied IT loads and equipment density. Outlet-level control and monitoring facilitate targeted power delivery strategies and easier outlet management during maintenance windows.
  • Security and reliability: Role-based access, audit trails, and secure communications to protect configuration data and event records. Built for high reliability with robust physical build and safety certifications appropriate to enterprise deployments.
  • Physical characteristics: Horizontal 19" rack-mount form factor with design features to ease installation, cable management, and airflow. Exact dimensions, weight, and mounting hardware vary by SKU; consult the datasheet for precise specifications.
  • Certifications and standards: Generally aligned with industry safety and EMC standards applicable to data center hardware (UL, CE, and related certifications, depending on regional variant and SKU).

how to install Panduit P08E18M

Installing the Panduit P08E18M iPDU involves a straightforward sequence to ensure optimal performance, safety, and long-term reliability. Begin by selecting a suitable 19-inch rack location with adequate clearance for cable management and airflow. Mount the iPDU horizontally in the rack using the provided rails or mounting brackets, ensuring a secure fit that minimizes movement during maintenance. Route AC power cables to a dedicated circuit or UPS/protection device, avoiding daisy-chained power sources that can compromise protection and monitoring accuracy. Connect IT loads to the iPDU’s configured outlet banks, grouping devices with similar cooling and electrical requirements to simplify management and improve thermal balance. Establish network connectivity by connecting the iPDU’s Ethernet port to your management network, and access the web UI or API to configure IP address, DNS, and access credentials. Enable power and environmental monitoring features, set alert thresholds for temperature, humidity, and current per outlet, and tailor notification channels to your operations team. Integrate the iPDU with your DCIM, ITSM, or centralized monitoring solution for consolidated visibility and alarm correlation. Finally, perform a practical test: verify per-outlet metering accuracy, test alert delivery, and simulate a non-critical load event to confirm proper automatic responses. Routine checks, firmware updates, and periodic calibration will help maintain peak accuracy and reliability over the life of the data center deployment.

Frequently asked questions

  • Q: What is the Panduit P08E18M Horizontal Intelligent Power Distribution Unit designed to do?

    A: It combines power distribution with advanced monitoring, metering, and environmental sensing at the rack level. This enables real-time visibility into energy usage, temperature, and humidity, along with proactive alerting and control to protect critical IT equipment and optimize data center efficiency.

  • Q: How does outlet-level monitoring benefit my data center?

    A: Outlet-level monitoring reveals exactly which devices are consuming the most power, helps balance loads to avoid overloads, supports accurate chargeback or capacity planning, and enables targeted energy-savings initiatives without compromising performance.

  • Q: Can I integrate the iPDU with my existing DCIM or management systems?

    A: Yes. The Panduit iPDU is designed for integration via standard interfaces such as web UI, SNMP, and API access, making it compatible with common DCIM solutions and IT service management workflows.

  • Q: What safety and reliability features are included?

    A: The unit provides overload detection, configurable protection, and secure access controls. It supports alerting and automatic responses to abnormal conditions, helping prevent outages and equipment damage while maintaining uptime.

  • Q: How do I know which specifications apply to my SKU?

    A: Exact specifications, including outlet configurations, dimensions, and supported features, vary by SKU and regional variant. Always refer to the official datasheet or product documentation for your specific SKU and region to confirm numbers and capabilities.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed