Panduit P20B16M Vertical Basic Power Distribution Unit

PanduitSKU: 12748861

Price:
Sale price$364.38

Description

Panduit P20B16M Vertical Basic Power Distribution Unit

Elevate your rack efficiency with the Panduit P20B16M Vertical Basic Power Distribution Unit. engineered for reliability, cost-effectiveness, and scalable power distribution, this PDU is designed to meet the demanding needs of modern data centers, server rooms, and network closets. The P20B16M blends flexibility and compact vertical form with a robust feature set that supports a variety of input configurations (Single or Three Phase; Delta or WYE) and outlet arrangements (IEC C13, C19, or NEMA compliant). With one of the highest outlet densities available in its class, it maximizes rack space while simplifying power routing and management. This basic PDU is built for durability, ease of installation, and straightforward maintenance, making it a trusted backbone for critical IT infrastructure.

  • High-density, space-saving vertical design: The P20B16M delivers a dense outlet configuration in a compact vertical footprint, enabling you to power more devices per rack without sacrificing accessibility or airflow. Its slim profile fits snugly into dense 19-inch racks, helping you optimize every U of rack space for servers, storage, and networking gear.
  • Flexible input and output options: Configure the PDU for Single Phase or Three Phase power and choose from Delta or WYE input schemes, along with outlet configurations that include IEC C13, IEC C19, or NEMA variants. This versatility makes it suitable for a variety of regional electrical standards and data-center architectures, reducing the need for multiple PDUs to cover different circuits.
  • Durable construction and reliable protection: Built to withstand the rigors of data-center environments, the P20B16M offers solid construction and dependable protection for critical equipment. It is designed to manage in-rack loads with balanced distribution, protecting connected devices from overcurrent conditions while keeping downtime to a minimum.
  • Rack-mount-ready convenience: As a vertical PDU, the P20B16M is optimized for 19-inch racks, enabling straightforward installation and clean cable management. The vertical orientation helps with airflow, cable routing, and accessibility for maintenance, making it a practical choice for IT rooms, colocation facilities, and laboratory environments.
  • Simple deployment with scalable power management: Panduit’s basic rack PDUs provide an economical entry point for reliable power distribution. The P20B16M is designed for easy installation, straightforward wiring, and reliable performance, while still offering enough flexibility to accommodate future expansion and changing device loads as your infrastructure evolves.

Technical Details of Panduit P20B16M Vertical Basic Power Distribution Unit

  • Model: P20B16M
  • Product family: Vertical Basic Rack PDU
  • Mounting: Vertical, 19-inch rack-compatible
  • Inputs: Single Phase or Three Phase configurations (Delta or WYE depending on configuration)
  • Outlets: Configurable to IEC C13, IEC C19, or NEMA outlets (model-dependent)
  • Voltage range: Configurable by regional standard (typical 100–240V AC ranges across configurations)
  • Current rating: Configurable by model; designed for reliable distribution within the rated ampacity
  • Construction: Lightweight yet durable, designed for rack integration and long-term use
  • Protection: Overcurrent protection and circuit protection appropriate to configuration; supports safe, organized power distribution
  • Compliance: Designed to meet industry standards for rack PDUs and electrical safety; consult official datasheet for exact certifications

How to install Panduit P20B16M

Installing the Panduit P20B16M is a straightforward process that enhances rack power management while minimizing downtime. Follow these steps to ensure a safe and effective deployment:

  • Prepare the rack: Ensure your 19-inch rack is clean, properly grounded, and capable of supporting the load distribution. Verify that the mounting rails and hardware are compatible with vertical PDUs and the rack’s depth.
  • Choose the correct configuration: Confirm whether your environment requires Single Phase or Three Phase input and select the appropriate outlet configuration (IEC C13, C19, or NEMA). This ensures you match the PDU to your devices and electrical system.
  • Mount the PDU vertically: Slide the P20B16M into the rear of the rack or the appropriate mounting location, aligning with the rack’s mounting holes. Secure the unit with the provided screws or hardware, ensuring it is firmly fastened and level to prevent cable strain.
  • Connect the input power: With power off, connect the PDU’s input to the corresponding power source using the appropriate inlet or power cable for your configuration. Verify that the input circuit is rated for the total anticipated load and that grounding is properly established.
  • Route and configure outlets: Organize power cables from critical devices to the PDU outlets. Distribute load evenly across banks to maintain balanced power delivery and minimize hotspot risk. Use cable management to keep outlets accessible for maintenance and future expansions.
  • Label and test: Label each outlet or bank according to connected devices for quick identification during troubleshooting. Re-energize the rack and conduct a brief functional test, ensuring devices power on correctly and that any protection features function as intended.

Frequently asked questions

  • Q: What equipment is best suited for the Panduit P20B16M Vertical Basic PDU?
    A: The P20B16M is ideal for powering servers, switches, storage arrays, routers, and other rack-mounted IT gear in data centers, lab environments, and network closets. Its high-density, vertical design makes it particularly well-suited for dense racks where space optimization is critical.
  • Q: Does the P20B16M support both single-phase and three-phase power?
    A: Yes. Panduit’s PDU line is designed to accommodate various electrical configurations, including single-phase and three-phase inputs, to suit different data-center electrical architectures (Delta or WYE) depending on the model and region.
  • Q: What outlet configurations are available?
    A: The P20B16M can be configured with IEC C13, IEC C19, or NEMA-style outlets, with options varying by model. This flexibility allows you to match your devices’ power connectors and regional standards efficiently.
  • Q: How can I monitor power distribution and load on the PDU?
    A: Basic PDUs provide straightforward power distribution, while some configurations offer monitoring capabilities or remote management. For precise monitoring features, refer to the official datasheet for the P20B16M configuration you select. Always ensure you stay within the rated current to protect connected equipment.
  • Q: Are there safety and installation considerations?
    A: Absolutely. Always power down equipment during installation, ensure proper grounding, and avoid overloading outlets. Use appropriate cable management and labeling to simplify maintenance. If you are unsure about electrical configurations or mounting, consult qualified personnel or Panduit support for guidance.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed