Description
The Panduit SmartZone G5 iPDU, manifested in the P24D31M vertical form factor, is more than a power strip. It is a comprehensive power distribution and environmental intelligence solution engineered for modern data centers, colocation facilities, and enterprise IT rooms. Designed to sit at the cabinet or rack level, this iPDU continuously monitors electrical power, detects overloads, and tracks critical environmental conditions that can affect uptime and performance. By combining precise energy metering with proactive monitoring, the P24D31M helps IT teams optimize energy use, reduce risk of outages, and gain actionable visibility into the health of the data center’s most vital assets.
- Comprehensive power distribution with real-time energy measurement: The P24D31M integrates a robust power distribution framework with advanced energy metering, delivering real-time data on voltage, current, power, and energy consumption. Its per-outlet monitoring capabilities let you see which devices draw the most power, enabling smarter capacity planning, better load balancing, and targeted conservation strategies at the rack level.
- Intelligent overload protection and proactive alerts: Built to prevent outages, the iPDU continuously scans electrical circuits for overloads and abnormal conditions. configurable alarms and thresholds alert administrators the moment a risk is detected, helping you take immediate action before IT services are impacted. This proactive approach reduces mean time to recovery and extends equipment life by preventing stress on power rails.
- Advanced environmental sensing for rack-level health: Beyond power, the P24D31M brings environmental intelligence to the cabinet with sensors that monitor temperature, humidity, and airflow. By correlating electrical load with environmental data, you can identify hotspots, optimize cooling strategies, and ensure lamps, servers, and storage devices operate within safe conditions for longer lifespans.
- Remote management, analytics, and seamless integration: The iPDU includes secure remote management via web UI, SNMP, and other standard protocols. Rich dashboards, automated reporting, and event logs provide deep analytics for capacity planning and incident investigation. Integrations with DCIM tools let you centralize monitoring across your data center floor, improving situational awareness and operational efficiency.
- Flexible installation and durable design for data center reliability: The vertical form factor is optimized for dense rack environments, delivering a compact footprint without sacrificing access to outlets or sensors. Its rugged construction supports mission-critical deployments, and its modular approach accommodates future scalability, ensuring long-term value as IT deployments evolve.
Technical Details of Panduit P24D31M
- Model: Panduit P24D31M Vertical iPDU (SmartZone G5)
- Monitoring Capabilities: Real-time power usage, per-outlet measurements, total energy consumption, circuit overload detection
- Environmental Sensors: Temperature, humidity, and airflow monitoring at the rack/cabinet level
- Management & Connectivity: Web-based management interface, SNMP support, alerting and event logging
- Physical Configuration: Vertical rack-mountable design, compatible with standard 19-inch racks
How to install Panduit P24D31M
Preparing for installation begins with a plan to place the P24D31M in a suitable rack location with adequate airflow and accessibility for cabling and maintenance. Ensure the rack area meets the recommended temperature range and that there is network connectivity for management access. Separate high-power devices from sensitive equipment to minimize electrical interference and ensure proper grounding for safety.
Step 1: Mount the iPDU in the rack. Use the supplied mounting hardware to secure the unit to a stable rack rail, ensuring there is sufficient clearance for cable management and ventilation. The vertical orientation should align with the rack’s rear rail to enable clean cable routing and easy access to outlets.
Step 2: Connect the power supply. Attach the iPDU’s input power cord to a suitable power source that meets the unit’s electrical requirements. Verify that the source is on, stable, and wired to a dedicated circuit where possible to minimize noise and voltage fluctuations that can affect measurements.
Step 3: Cable IT devices to the PDU outlets. Use appropriately rated power cables to connect servers, storage arrays, and networking gear to the PDU outlets. Keep power cables organized to prevent overheating and to support easy identification of circuits during troubleshooting.
Step 4: Establish management connectivity. Connect the iPDU’s management port to your network using a secure Ethernet connection. Configure IP address, gateway, and DNS as needed so you can access the web UI and begin collecting telemetry data.
Step 5: Configure monitoring and alerts. Log in to the web UI and set up alarm thresholds for temperature, humidity, and power load. Enable event logging, email or SNMP trap notifications, and define dashboards that reflect the data center’s unique topology and compliance requirements.
Step 6: Calibrate sensors and validate operation. If the iPDU permits calibration, perform sensor calibration according to the vendor guidelines. Confirm that outlet-level readings, total energy usage, and environmental sensors are reporting accurately. Validate that alarms trigger as configured and that data populates in dashboards and reports for ongoing analysis.
Step 7: Integrate with DCIM and ITSM workflows. If you use a Data Center Infrastructure Management (DCIM) platform or IT service management tools, map the iPDU data into these systems to enable centralized monitoring, incident correlation, and proactive capacity planning. This integration unlocks deeper insights and reduces the effort required to maintain optimal data center performance.
Step 8: Train operators and establish operational procedures. Document access credentials, maintenance windows, and escalation paths. Train staff on how to interpret energy and environmental data, respond to alerts, and perform routine checks that keep the P24D31M functioning reliably over time.
The Panduit P24D31M is designed to streamline power management and environmental visibility in demanding data center environments. By combining robust electrical distribution with real-time telemetry and intelligent alerting, this vertical iPDU helps IT teams prevent outages, optimize cooling, and maximize equipment effectiveness—ultimately contributing to lower total cost of ownership and higher service levels for end users.
Frequently asked questions
Q: What is the Panduit P24D31M used for? A: It is a vertical intelligent PDU that distributes power to rack equipment while providing real-time energy measurement, per-outlet monitoring, and environmental sensing to improve data center reliability and efficiency.
Q: What kind of alerts does the P24D31M support? A: The iPDU supports configurable thresholds and alerts for overload conditions, temperature, humidity, and other environmental metrics. Alerts can be delivered via the web UI, email, or SNMP traps depending on configuration.
Q: Can the P24D31M integrate with a DCIM platform? A: Yes. The device offers standard management interfaces (such as SNMP and a web-based interface) that enable integration with DCIM tools for centralized monitoring and analytics.
Q: How does energy data help with IT operations? A: Real-time energy data supports capacity planning, cost allocation, and efficiency initiatives. By identifying peak loads and underutilized circuits, teams can rebalance workloads, optimize cooling, and reduce energy waste in the data center.
Q: Is installation difficult for non-specialists? A: While a basic level of electrical safety and rack handling knowledge is recommended, Panduit provides configuration guidance and a user-friendly interface to simplify setup. If in doubt, consult your facilities or IT team or engage a qualified technician.