Panduit SmartZone G5 24-Outlet PDU — 20×C13 / 4×C19, Monitored & Switched

PanduitSKU: 12727240

Price:
Sale price$2,791.35

Description

Panduit SmartZone G5 Intelligent 24-Outlets PDU – Monitored, 415 V AC, NEMA L6-30P, 20x IEC 60320 C13 + 4x IEC 60320 C19, 0U Rack-Mountable

Experience enterprise-class power management with the Panduit SmartZone G5 Intelligent 24-Outlets PDU. Designed for data centers, laboratories, and critical IT environments, this monitored power distribution unit delivers precise outlet-level data, proactive alerts, and scalable remote management. With a compact 0U vertical form factor, it fits seamlessly into dense rack environments while supporting a high-density mix of IEC C13 and C19 outlets. The PDU's NEMA L6-30P inlet and 415 V AC capability provide flexible, safe power delivery for a variety of equipment configurations, ensuring uptime and operational visibility across the data center stack.

  • Monitored power distribution with remote visibility: Real-time monitoring of voltage, current, and per-outlet load allows you to track power consumption, identify hotspots, and prevent overloads before they impact critical devices. With remote access via the network, administrators can view live data, generate reports, and receive alerts when thresholds are exceeded.
  • High-density outlet configuration for versatile rack deployments: The unit provides 24 outlets in a thoughtful mix of 20 IEC 60320 C13 and 4 IEC 60320 C19 receptacles, supporting a wide range of servers, storage, network gear, and peripherals. This configuration enables efficient power distribution for modern IT ecosystems while maintaining easy cable routing for maintenance and upgrades.
  • Robust power input for demanding environments: The SmartZone G5 is designed for 415 V AC operation via a NEMA L6-30P inlet, delivering dependable power to mission-critical devices. The 0U form factor minimizes rack footprint while maintaining strong electrical performance and fault tolerance for multi-rack deployments.
  • Integrated network management for proactive control: With an RJ-45 network port, the PDU enables centralized monitoring, alerting, and control across the data center. This enables IT teams to implement consistent power policies, automate responses to abnormal conditions, and integrate with existing monitoring platforms and dashboards.
  • Rack-mountable, space-saving design with scalable management: The vertical, 0U profile fits into dense racks, leaving room for other essential equipment. Its intelligent design supports scalable management across multiple PDUs, helping facilities engineers orchestrate power across larger deployments without sacrificing visibility or control.

Technical Details of Panduit SmartZone G5 Intelligent 24-Outlets PDU

  • Outlets: 24 total — 20 x IEC 60320 C13, 4 x IEC 60320 C19, arranged for flexible device compatibility and neat cabling in crowded rack spaces.
  • Input / Inlet: NEMA L6-30P connector, suitable for 415 V AC operation. This configuration supports robust, high-current distribution for demanding equipment in data centers and labs.
  • Form factor: 0U vertical design intended for 19-inch racks. The compact footprint preserves space for additional devices while delivering full-featured PDUs for power distribution and monitoring.
  • Monitoring & management: Monitored PDU with remote monitoring capabilities via the network (RJ-45). Provides real-time data, event alerts, and outlet-level visibility to support proactive maintenance and efficient energy management.
  • Power protection & reliability: Built to provide stable power delivery and fault detection for critical equipment. The smart monitoring capabilities support proactive maintenance, energy auditing, and reduced downtime through early warning of electrical anomalies.
  • Connectivity & integration: Ethernet-based management allows integration with existing data center infrastructure monitoring, centralized alerting systems, and reporting workflows. Configuration can be performed through the PDU’s web interface or compatible management platforms.
  • Operational flexibility: The combination of 24 outlets and monitored capabilities makes the SmartZone G5 suitable for a range of deployments—from single-rack units to multi-rack data centers—where visibility into power consumption and load distribution is essential for capacity planning and sustainability initiatives.
  • Safety & compliance considerations: Designed for professional IT environments, with robust electrical protection features and adherence to industry standards for safe operation in demanding settings.

How to install Panduit SmartZone G5 Intelligent 24-Outlets PDU

  • Prepare the rack and workspace: Confirm your rack is a standard 19-inch cabinet with mounting rails and adequate clearance for cable management and cooling. Inspect the PDU and mounting hardware upon delivery to ensure there is no damage.
  • Mount the PDU in the rack: Attach the PDU to the rack using the provided mounting brackets and appropriate screws. Align the unit to ensure the outlets are accessible and that cabling can be routed cleanly along the rear of the rack.
  • Connect the input power: Plug the NEMA L6-30P inlet into the 415 V AC power source that matches the PDU’s rating and circuit protection. Ensure that the circuit breaker feeding the PDU is sized appropriately for continuous load and that all safety clearances are maintained.
  • Route and label outlets: Organize power cables from servers, storage, and network devices to the 20 C13 and 4 C19 outlets. Use color-coding or labeling to simplify future maintenance and troubleshooting.
  • Configure network connectivity: Connect an Ethernet cable from the PDU’s RJ-45 port to your management network or a dedicated monitoring appliance. Ensure network connectivity and verify that the PDU can be reached from your monitoring console or IP-based management tool.
  • Initial power-on and verification: Power up the PDU and verify that all outlets are recognized by the management interface. Check for any fault indicators and confirm that real-time metering data is being reported for each outlet where supported.
  • Set up monitoring, alerts, and policies: Access the PDU’s web interface to configure IP addressing (static or DHCP), user access, and alert thresholds. Create notification rules (email, SNMP traps, or other supported channels) to receive proactive warnings when loads exceed configured limits or when device faults occur.
  • Test and document: Run a controlled load test on representative devices to confirm accurate metering and outlet status. Document the configuration for future audits and maintenance cycles, and schedule routine checks to ensure continued reliability and data accuracy.

Frequently asked questions

  • Q: What outlets are included on the Panduit SmartZone G5 24-Outlets PDU?
    A: The unit features 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets, designed to support a broad range of IT equipment while keeping cabling organized and accessible.
  • Q: What power input does this PDU require?
    A: It uses a NEMA L6-30P inlet rated for 415 V AC operation, enabling robust power delivery to high-density racks and demanding devices.
  • Q: Is the PDU rack-mountable?
    A: Yes. It is a 0U vertical PDU designed for 19-inch racks, allowing tight integration into dense equipment layouts without consuming rack space.
  • Q: Can I monitor power usage remotely?
    A: Absolutely. The PDU includes network (RJ-45) connectivity for remote monitoring and management, enabling real-time visibility, alerts, and data collection from anywhere on the management network.
  • Q: How can I manage alerts and thresholds?
    A: Use the PDU’s web interface or your integrated monitoring platform to set threshold-based alerts for voltage, current, and per-outlet load. Alerts can be delivered via email, SNMP traps, or other supported channels to ensure timely notifications for preventive action.