Panduit SmartZone Locking Power Cord — IEC C14 to IEC C13EA

PanduitSKU: 12738897

Price:
Sale price$259.23

Description

The Panduit SmartZone Standard Power Cord is a dependable, non-locking solution designed to power rack-mounted gear in data center cabinets with clarity and reliability. Built to complement the SmartZone ecosystem, these standard cords efficiently transfer power from the rack power distribution unit (PDU) to active devices such as servers, switches, storage arrays, and other critical equipment. Available in a range of colors and lengths, they simplify cable management, improve airflow, and reduce downtime by delivering a straightforward, consistent power path across the data center floor. Whether you’re outfitting a new rack, upgrading a PDU setup, or implementing color-coded organization for asset management, the Panduit SmartZone Standard Power Cord offers a simple, scalable solution for clean, dependable power delivery.

  • Designed to transfer power from the rack PDU to active gear in data center cabinets, with multiple length options and colors to fit your deployment strategy and color-coding plan.
  • Durable construction optimized for data center environments, featuring a robust jacket and reliable copper conductors that stand up to frequent handling, routing in tight rack spaces, and ongoing cable management tasks.
  • Non-locking standard configuration provides a universal, straightforward connection that minimizes maintenance complexity while delivering dependable power paths for everyday workloads.
  • Color-coded options support efficient inventory control, asset tracking, and organized cable management in high-density deployments, helping technicians identify circuits quickly during installs or maintenance.
  • Seamless compatibility with Panduit SmartZone PDUs and widely used rack gear, enabling scalable deployments and a consistent power distribution experience across your data center.

Technical Details of Panduit SmartZone Standard Power Cord

  • Product type: Standard power cord (non-locking) designed for use with Panduit SmartZone systems and data center racks.
  • Locking: Non-locking configuration (standard power cord option).
  • Length options: Available in multiple lengths to fit diverse rack layouts (examples include shorter and longer options to match cabinet depth).
  • Color options: Various colors available to support color-coded cable management and quick identification in dense deployments.
  • Conductor material: Copper conductors delivering reliable power transfer and consistent electrical performance.
  • Jacket material: Durable jacket suitable for data center environments and frequent handling during installation and maintenance.
  • Voltage and current: SKU-specific specifications vary; typical data center cords are designed to match common PDU and equipment inputs. Verify the exact rating on the product SKU packaging to ensure proper voltage and current alignment with your hardware.
  • Compliance and compatibility: Designed to integrate with Panduit SmartZone components and compatible with a wide range of rack-mounted devices that use standard power inlet configurations; compatibility should be confirmed with your specific PDU and equipment inputs.
  • RoHS and safety considerations: Standard industry practices apply for data center power cords; consult the packaging and product labeling for any region-specific compliance notes.

How to install Panduit SmartZone Standard Power Cord

Installing the Panduit SmartZone Standard Power Cord is a straightforward process that supports fast deployment and organized cabling in busy data center environments. Follow these steps to ensure a safe, reliable connection between your rack PDU and active gear:

1) Plan and verify: Before touching equipment, review your data center's power plan. Identify the PDU output you will use and confirm the input requirements of the target devices (voltage, amperage, and connector type). Select the appropriate length and color from the available SmartZone Standard Power Cord options to fit your rack depth and cable management strategy.

2) Power down and safety check: If possible, power down the devices you will connect or follow your organization's lockout/tagout procedures. Ensure hands are dry, and you are working in a safe, static-free environment. Verifying power at the intended outlets with appropriate equipment reduces the risk of unexpected energization.

3) Route and organize: Plan a clean routing path from the PDU to each device inlet. Use cable management accessories like Velcro ties, cable combs, or guides to align cords neatly along the rack rails. Keeping cords organized enhances airflow, simplifies future service, and minimizes snags during maintenance.

4) Connect securely: Align the Cord’s power connector with the device inlet and insert firmly until you hear or feel a definitive seating. For standard cords, ensure the connection sits flush and there is no undue strain on the cable. Repeat for each device, taking care not to bend the conductors sharply or kink the jacket.

5) Manage slack and labeling: Leave a small amount of slack at each connection to absorb movement during equipment maintenance, but avoid creating loose loops in front of vents or fans. Label each cord or color-code it consistently with your data center standards to facilitate future changes or troubleshooting.

6) Power-up and test: Restore power and perform a functional test on each connected device to verify that the power path is stable. If you notice any irregularities, power down safely and recheck connections. Document the configuration for future reference.

Additional tips: Keep spare lengths in your inventory to shorten deployment times for new blade servers or expansion cabinets. For high-density racks, consider pairing standard cords with appropriate color-coding strategies to maintain clear separation between power and data cables and to sustain optimal airflow.

Frequently asked questions

  • What is the difference between Panduit SmartZone Standard Power Cord and locking cords? The Standard Power Cord is a non-locking cable designed for straightforward, reliable power delivery between PDUs and equipment. Panduit also offers dual locking power cords that resist accidental disconnections in vibration-prone environments or where secure retention is required.
  • What lengths and colors are available? The SmartZone Standard Power Cord line is offered in multiple lengths to fit different cabinet depths, and in a range of colors to support color-coded cable management. Availability varies by SKU, so select the length and color that best matches your rack layout and asset-tracking plan.
  • Are these cords compatible with non-Panduit equipment? Yes, as long as the connector type, voltage, and current ratings match the inlet on your device and PDU. Always verify that the SKU’s specifications align with your hardware inputs before purchase.
  • How do I choose the right color and length? Color can simplify inventory and maintenance by linking cords to circuits, zones, or devices. Length should accommodate your rack depth plus a small amount of slack for movement, with enough extra length to route cleanly without creating tension or interference with airflow.
  • Do these cords meet data center safety standards? Panduit designs these cables for typical data center environments and professional deployments. Check the product packaging for exact rating details and any region-specific safety or compliance notes relevant to your facility.
  • Where can I find the exact technical specifications? Technical details vary by SKU, including voltage, amperage, and connector specifics. Refer to the product listing for the exact SKU you plan to purchase to confirm full specifications before ordering.