Description
Panduit SmartZone MI 24-Outlets PDU
The Panduit SmartZone MI 24-Outlets PDU is a high-density, 0U, vertical rack‑mount power distribution solution designed for demanding data centers and enterprise IT environments. This monitored PDU provides reliable power delivery to racks filled with servers, storage, and networking gear while delivering granular visibility into energy usage and device health. With 24 outlets—comprising 12 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles—it supports a wide range of equipment in a compact footprint, helping you maximize rack space without compromising reliability or control. The SmartZone MI model is purpose-built for centralized energy management, enabling IT and facilities teams to remotely monitor electrical parameters, receive timely alerts, and implement policy-based power management across the entire rack. In practice, this means improved uptime, optimized energy consumption, and streamlined operations for data centers and distributed IT closets alike.
- Monitored power distribution with remote visibility: The SmartZone MI PDU continuously monitors voltage, current, power, energy consumption, and outlet-level conditions. Through a simple network interface, administrators can access real-time data, historical trends, and granular insights that drive proactive maintenance and informed capacity planning. This monitoring capability is essential for identifying hotspots, balancing loads, and staying ahead of potential outages before they impact services.
- 24 outlets configured for versatile equipment needs: The unit features 12 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles, delivering flexible power distribution to a mix of servers, storage devices, and networking gear. This configuration supports standard IT equipment while enabling neat, organized cabling, essential in busy racks where space and airflow matter. The distinct outlet types help you match devices to the appropriate power profile and cord length.
- 0U vertical, rack-mountable design for space efficiency: Engineered to install in 19" racks without occupying valuable rack units, the PDU minimizes footprint while maximizing accessibility. Its vertical form factor aligns with front- or rear-access installations, helping you maintain clean cable routing and better airflow within crowded enclosures. This design is ideal for modern data centers seeking dense power distribution without adding bulk to the rack.
- Network-based management for scalable control: With an integrated RJ-45 network interface, the Panduit SmartZone MI PDU enables remote monitoring, alerting, and control over standard IP networks. You can configure thresholds, receive alerts via email or management software, and integrate PDU data into broader data-center infrastructure management (DCIM) workflows. This network capability supports centralized governance and faster triage when electrical conditions change.
- Reliability, policy-driven power management, and IT-saving insights: The PDU is designed to contribute to uptime and operational efficiency by letting you set alarms, implement load-shedding policies, and optimize energy usage across your rack. By capturing outlet-level energy data, it becomes easier to identify underutilized outlets, repurpose loads, and drive energy-savings strategies without sacrificing performance or availability.
Technical Details of Panduit SmartZone MI 24-Outlets PDU
- Product type: Monitored PDU designed for data centers and IT closets.
- Outlet configuration: 24 total outlets — 12 IEC 60320 C13 and 12 IEC 60320 C19 receptacles.
- Input voltage: 230 V AC, compatible with standard data-center power distribution environments.
- Frequency: 50/60 Hz operation, suitable for global deployments.
- Mounting: 0U vertical form factor, rack-mountable in standard 19" racks.
- Network interface: RJ-45 Ethernet connection for remote monitoring and management.
- Monitoring capabilities: Real-time measurements of voltage, current, power, energy per outlet, and other electrical parameters; supports alerting and data export for analysis.
- Management integration: Designed for integration with the Panduit SmartZone ecosystem and compatible IP-based management workflows (e.g., SNMP-based monitoring and DCIM tools).
- Physical attributes: Compact, rugged construction suitable for dense rack environments and busy data-center settings.
- Application: Ideal for data centers, enterprise IT closets, and other environments requiring centralized power management and proactive fault detection.
how to install Panduit SmartZone MI 24-Outlets PDU
- Prepare the rack and mounting hardware: Ensure your rack has available vertical mounting space in a standard 19" enclosure. Collect the necessary screws or cage nuts and confirm the rails are properly aligned for 0U mounting. Verify that you have convenient access to both the power input and the RJ-45 network port once installed.
- Mount the PDU in the rack: Slide the PDU into the selected vertical slot. Secure it using the appropriate mounting hardware, making sure it is firmly seated and level. The 0U profile means you won’t consume precious rack height, so double-check door clearance and nearby cable routes to avoid pinching cables.
- Connect power and network: Plug the PDU’s input power cord into a suitable 230 V power source. Route the power and data cables neatly to maintain airflow and reduce cable strain. Connect an RJ-45 Ethernet cable from the PDU to your network switch or management appliance consistent with your DCIM or monitoring strategy.
- Configure monitoring and alerts: Access the PDU through your chosen management platform or the built-in interface, if available. Configure parameters such as voltage thresholds, current limits, and alert recipients. Establish alarm rules for over-current, under-voltage, or abnormal energy usage to receive prompt notifications and prevent unexpected downtime.
- Connect devices and label for clarity: Attach devices to the C13 and C19 outlets according to their power requirements and cable lengths. Label outlets for easy diagnostics and to support consistent maintenance procedures, ensuring critical devices have dedicated, reliable power paths.
- Verify operation and document configuration: Power on the rack and verify that all devices initialize correctly. Check that monitoring data is flowing to the management system and that alerts trigger as expected. Document the configuration for future audits and future expansions of the power infrastructure.
Frequently asked questions
- What is a monitored PDU and why do I need one? A monitored PDU provides real-time electrical measurements and remote management capabilities. It enables proactive fault detection, load balancing, and energy optimization across IT racks, reducing the risk of unexpected outages and enabling data centers to run more efficiently.
- How many outlets does this PDU have and what outlet types are included? It features 24 outlets in total: 12 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles, offering compatibility with a wide range of data-center equipment power cords.
- What voltage does it operate at? The Panduit SmartZone MI 24-Outlets PDU operates at 230 V AC, suitable for standard data-center power systems in many regions. It supports 50/60 Hz input frequencies, enabling global deployment options.
- How do I manage and monitor the PDU? The PDU includes an RJ-45 network interface for remote monitoring and control. It can be integrated into the Panduit SmartZone ecosystem or other IP-based management tools to monitor electrical parameters, receive alerts, and enforce power policies across racks.
- Is this PDU suitable for 0U, space-constrained installations? Yes. Its 0U vertical design is specifically intended for dense data-center racks, delivering ample power capacity without consuming valuable rack height and helping maintain airflow efficiency.
Customer reviews
Showing - Of Reviews