Panduit SmartZone MI 24-Outlets PDU

PanduitSKU: 12730186

Price:
Sale price$1,531.55

Description

Panduit SmartZone MI 24-Outlets PDU

Designed for demanding data centers, server rooms, and network closets, the Panduit SmartZone MI 24-Outlets PDU delivers reliable power protection and intelligent monitoring in a compact, space-efficient form. This monitored PDU combines a rugged NEMA L15-30P inlet with a total of 24 outlets (18 IEC 60320 C13 and 6 IEC 60320 C19) and network-based visibility to help you safeguard critical loads, optimize energy use, and simplify management in enterprise environments.

  • Monitored PDU with remote voltage monitoring across single- or three-phase loads, enabling proactive alerts and centralized power management over a secure network connection.
  • Flexible outlet configuration: 24 total outlets consisting of 18 IEC 60320 C13 and 6 IEC 60320 C19 receptacles, all fed from a NEMA L15-30P input for reliable power distribution in mixed equipment scenarios.
  • Robust 230 V AC power suitable for data center gear, networking devices, and other high-demand equipment, delivering capacity for dense rack deployments while maintaining efficiency and protection.
  • Space-saving 0U vertical rack-mount design that fits seamlessly into standard 19-inch racks, maximizing usable rack space without increasing footprint.
  • Network-enabled power management with RJ-45 connectivity, enabling secure remote monitoring, event logging, and control as part of a broader data-center infrastructure management strategy.

Technical Details of Panduit SmartZone MI 24-Outlets PDU

  • Model: Panduit SmartZone MI 24-Outlets PDU (Monitored)
  • Input / Inlet: NEMA L15-30P
  • Outlets: 18 x IEC 60320 C13, 6 x IEC 60320 C19
  • Voltage: 230 V AC
  • Output Count: 24 total outlets
  • Form Factor: 0U, Vertical, Rack-mountable (19-inch rack compatible)
  • Monitoring: Monitored PDU with remote monitoring of single- and three-phase voltage
  • Networking: RJ-45 for network connectivity and management
  • Application: Power protection and power management for data centers and enterprise networks

how to install Panduit SmartZone MI 24-Outlets PDU

Installing the Panduit SmartZone MI 24-Outlets PDU is straightforward for IT staff and facilities teams familiar with standard 19-inch racks. Begin by locating a suitable rack space with adequate airflow and clearance for cable management. Mount the PDU in the vertical 0U space using the rack’s mounting hardware, ensuring the unit is level and securely fastened to prevent vibration or shifting during operation. Route the NEMA L15-30P power cable from a compatible main power circuit, and connect the PDU’s input plug to the circuit while accounting for any required distance to minimize voltage drop. After securing the physical installation, align each outlet with your equipment’s power cords to prevent strain on plugs and to promote organized cable management. Finally, connect the PDU to your network via the RJ-45 port and configure monitoring settings via the PDU’s management interface or your existing data-center infrastructure management (DCIM) system. Once configured, power-on the connected devices and verify that all outlets are operational and reporting correctly through the monitoring interface. In environments with multiple PDUs, establish alert thresholds for voltage, current, and outlet temperature as needed, and integrate with your centralized alerting platform to receive timely notifications.

Frequently asked questions

  • What is a monitored PDU and why do I need one? A monitored PDU provides remote visibility into electrical parameters such as voltage, current, and outlet status. This enables proactive protection, better capacity planning, and alert-driven maintenance for critical equipment.
  • What outlets does this PDU include? The unit features 18 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets, totaling 24 receptacles for expanding power distribution to a range of devices in a rack.
  • What inlet does it use and what voltage is supplied? It uses a NEMA L15-30P inlet and is designed for 230 V AC operation, suitable for data-center-grade power delivery.
  • Is this PDU compatible with standard racks? Yes, the 0U vertical form factor is designed for 19-inch racks and can be mounted in standard rack enclosures without occupying additional rack depth.
  • How do I monitor and manage this PDU? The PDU connects via RJ-45 and supports remote monitoring, which can be integrated into DCIM platforms or managed directly through its built-in interface for event reporting and alerts.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed