Panduit SmartZone U01S11V 1000VA Rack/Tower UPS

PanduitSKU: 12724739

Price:
Sale price$935.88

Description

Panduit SmartZone U01S11V 1000VA Rack/Tower UPS

The Panduit SmartZone U01S11V 1000VA Rack/Tower UPS is a purpose-built power protection solution that delivers clean, reliable electricity to critical IT equipment. Engineered as a pure Online Double Conversion system, it continuously converts incoming AC power to DC and back to stable AC output, ensuring exceptional power quality even in environments with frequent outages, voltage sags, and electrical noise. With a compact 1000 VA rating, this unit is designed for small data centers, server rooms, network closets, and professional office deployments where uptime and data integrity are paramount. Its flexible rack/tower form factor makes it simple to deploy in existing infrastructure, while the maintenance-free VRLA battery minimizes maintenance requirements and operational costs over the life of the system. The SmartZone U01S11V also offers scalable monitoring and management capabilities, enabling you to supervise, configure, and respond to power events from a single, centralized platform. Whether you’re protecting servers, switches, NAS devices, or critical workstations, this UPS provides the stability and resilience needed to keep critical workloads online and data safe.

  • Pure Online Double Conversion protection: The UPS maintains continuous, clean output by fully rectifying and inverting power, shielding connected equipment from input disturbances, outages, and harmonics while delivering consistent voltage regulation and surge suppression.
  • Flexible rack/tower deployment: Designed for versatile installation, the unit can be mounted in standard IT racks or configured as a standalone tower, optimizing space in data centers, network rooms, and office environments without compromising performance.
  • Maintenance-free VRLA battery: The sealed, valve-regulated lead-acid battery requires minimal maintenance and offers reliable backup time with smart battery management to extend service life and enhance safety.
  • High power quality and AVR support: Automatic Voltage Regulation and precise voltage control help sustain stable output during brownouts or minor input fluctuations, reducing the risk of data corruption and equipment stress.
  • Integrated management and monitoring: USB and RS-232 connectivity come standard, with optional network management cards for SNMP and remote monitoring, plus compatibility with Panduit SmartZone software for centralized power management across multiple UPS devices.

Technical Details of Panduit SmartZone U01S11V 1000VA Rack/Tower UPS

  • Topology: Online Double Conversion (pure online UPS) for continuous power conditioning and immediate transfer to battery backup during outages.
  • Power rating: 1000 VA / 700 W (typical) designed to protect critical IT equipment and small server workloads.
  • Input voltage: 120 VAC or 230 VAC, single-phase, with automatic sensing of 50/60 Hz, providing regional adaptability.
  • Output voltage: 120 VAC or 230 VAC selectable, delivering tight voltage regulation and clean sine-wave power to sensitive devices.
  • Form factor: Rack-mountable and tower-capable for flexible installation; front-access battery compartment and cable management considerations vary by configuration.
  • Battery type: Maintenance-free VRLA (sealed lead-acid) battery with smart health monitoring and easy replacement when required.
  • Battery runtime: Backup time varies with load; typical runtimes range from several minutes at modest loads to longer durations at lighter loads.
  • Management interfaces: USB and RS-232 ports are standard; optional network management card enables SNMP-based monitoring and remote control.
  • Efficiency: High efficiency in online operation to minimize energy losses and reduce heat output in data-center deployments.
  • Operating environment: Designed for controlled environments with specified temperature and humidity ranges to maximize battery life and performance.
  • Safety and compliance: Meets applicable safety and environmental standards and certifications for IT power protection equipment (CE, UL, RoHS variants).
  • Audible output: Quiet operation suitable for office and data-center spaces, with noise levels depending on load and configuration.

How to Install Panduit SmartZone U01S11V 1000VA Rack/Tower UPS

Preparing for installation starts with selecting a suitable location that provides adequate ventilation and access to the front panel for status checks and maintenance. Plan the rack or stand-alone space so cabling routes are clean, with enough clearance for the front-access battery bay and rear cord management. Prior to mounting, inspect the unit for any physical damage and confirm that the ambient temperature and humidity meet the operating specifications. If you are deploying in a rack, secure the UPS using the included mounting rails or brackets designed for standard 19-inch equipment racks. When placing the unit in a tower configuration, ensure it is on a stable, level surface away from foot traffic and sources of vibration. Use the correct input power cord for your region and ensure the circuit can supply the required current without tripping protective devices.

Mounting and cabling are followed by a quick initialization. Connect the UPS to the input power source, then attach the protected equipment (servers, switches, storage devices, or workstations) to the UPS’s output outlets. Use the front panel indicators to confirm proper operation and connect the USB or RS-232 communication port to a management PC or server. If you plan to monitor the unit remotely, install the optional network management card and configure the UPS in your centralized power management software. After the initial power-on, run a self-test to verify battery health and ensure the unit transitions smoothly between mains power and battery backup. Finally, program any regional settings, runtime preferences, alarm thresholds, and notification methods so you receive timely alerts during power events.

During operation, perform periodic battery tests to assess health and capacity. If the unit features an LCD or front-panel display, monitor battery status, load levels, and input/output voltages to maintain optimal performance. Regular maintenance should include keeping the surrounding area clean and free of dust, ensuring adequate airflow, and avoiding placement near heat sources. If external battery cabinets are used to extend runtime, follow the manufacturer’s guidelines for chaining and configuring battery strings to preserve system integrity. By following these steps, you ensure a reliable, long-lasting power protection solution that minimizes downtime and preserves data integrity for critical IT infrastructure.

Frequently asked questions

  • Q: What is the capacity and typical application for the SmartZone U01S11V?
  • The unit provides 1000 VA of online double-conversion protection, suitable for protecting a small server, network gear, or several critical workstations in professional IT environments.
  • Q: Can I install this UPS in a rack or in a tower configuration?
  • Yes. The U01S11V is designed for flexible deployment and can be mounted in standard IT racks or configured as a standalone tower to fit your space and workflow requirements.
  • Q: What management options are included, and are there upgrade paths?
  • Standard USB and RS-232 interfaces are provided, with an optional network management card for SNMP and remote monitoring. It integrates with Panduit SmartZone for centralized power management across multiple UPS devices.
  • Q: How long does the battery last, and what maintenance is required?
  • Backups vary with load, but the VRLA battery provides reliable runtime with smart battery management. The battery requires minimal maintenance, and replacement is straightforward when needed.