Description
Meet the Panduit SP6X88SD-C, a high-performance Cat 6A UTP modular plug engineered for reliable, high-speed Ethernet terminations. Designed to terminate 4-pair, 26 AWG patch cables with solid or stranded conductors, this modular plug delivers consistent impedance and durable connectivity for data centers, offices, and lab environments. Its robust construction is optimized for easy field or rack installations, helping technicians achieve clean, repeatable terminations with every job. If you’re upgrading network infrastructure or building a new patch panel, the SP6X88SD-C is built to deliver premium performance without compromising on ease of use or durability.
- Cat 6A UTP performance: Engineered to support high-bandwidth Ethernet, the SP6X88SD-C maintains a 100-ohm impedance design for stable signal integrity in 10GBASE-T channels and beyond, ensuring reliable data transmission over longer runs and in dense cabling environments.
- Four-pair, 26 AWG compatibility: Terminate standard 4-pair, 26 AWG patch cables with both solid and stranded conductors. This versatility makes it suitable for a wide range of network deployments, from data centers to small offices, without needing special cable or connector variations.
- Precise dimensions for compatibility: The plug accommodates a maximum conductor insulation diameter of 0.034 inches (0.86 mm) and a maximum jacket diameter of 0.25 inches (6.35 mm), providing a reliable fit with typical Cat 6A UTP cables and ensuring consistent seating in modular connectors and patch panels.
- Durable construction for rugged environments: Panduit engineered the SP6X88SD-C with a robust build that stands up to repeated terminations, high-density rack installations, and field use. Its durable housing helps resist wear during crimping and reduces the risk of stray strands or termination failures.
- Efficient, tool-friendly termination: This modular plug is designed for crimp-on termination with standard tools, enabling fast, repeatable connections. The combination of reliable materials and a clean termination profile minimizes rework and helps technicians meet tight project timelines.
Technical Details of Panduit SP6X88SD-C
- Product family: Cat 6A UTP modular plug
- Supports: 4-pair, 26 AWG patch cables (solid or stranded)
- Impedance: 100 ohms
- Conductor insulation diameter: 0.034 inches (0.86 mm)
- Maximum jacket diameter supported: 0.25 inches (6.35 mm)
- Termination: Crimp-on modular plug suitable for standard RJ45-style terminations
- Cable compatibility: Unshielded twisted pair (UTP)
- Conductor types: Compatible with both solid and stranded 26 AWG conductors
- Model: SP6X88SD-C
- Color considerations: Standard industry color-coding compatible with common RJ45 assemblies (color specifics may vary by project requirements)
How to Install Panduit SP6X88SD-C
- Prepare the cable: Select the correct length of 4-pair, 26 AWG UTP patch cable. Cut the cable cleanly and inspect for any nicked or damaged conductors. Remove the outer jacket to expose the four twisted pairs according to your preferred termination standard (T568A or T568B).
- Arrange the conductors: Align the individual conductors in the proper order and trim them so that they reach the termination slots of the SP6X88SD-C plug. Maintain consistent conductor lengths to ensure a clean seating in the plug and reliable contact.
- Insert into the plug: Carefully insert the conductors into the SP6X88SD-C so that each conductor reaches the termination cavity. Ensure there is no stray strand protruding and that the insulation stops at the correct depth for reliable contact.
- Crimp the plug: Use a compatible crimping tool designed for RJ45 modular plugs and the SP6X88SD-C. Apply firm, even pressure to secure the conductors, ensuring a solid crimp that holds the wires in place and creates robust electrical contact within the plug.
- Test the termination: After crimping, test the assembled connector with a qualified network cable tester. Verify continuity, pair integrity, and impedance to confirm a correct termination. If testing reveals any miswiring or poor contact, re-terminate with a fresh plug to ensure optimal performance.
Frequently Asked Questions
- Q: What type of cables does the Panduit SP6X88SD-C terminate? A: It terminates 4-pair, 26 AWG patch cables that can be solid or stranded and are unshielded twisted pair (UTP).
- Q: What is the impedance of this plug? A: It is designed for 100-ohm CAT 6A UTP channel performance, helping preserve signal integrity in high-speed Ethernet applications.
- Q: Can I use this plug with shielded cables? A: The SP6X88SD-C is specified for unshielded twisted pair (UTP) cables. For shielded installations, use shielded connectors designed for shielded cabling to maintain proper shielding benefits.
- Q: Is Cat 6A enough for 10G Ethernet? A: Yes. Cat 6A supports 10GBASE-T up to 100 meters when used with compliant components and proper channel design, making the SP6X88SD-C suitable for high-speed networks when paired with appropriate cables and network infrastructure.
- Q: How many terminations can I expect from the SP6X88SD-C in a dense data-center environment? A: The plug is designed for reliable, field-terminable connections in dense environments; ensure you use quality crimp tools and conductors to maximize channel performance and minimize rework.