Panduit Waterfall Trough for PR2V Managers, Black
Elevate your data center cabling with the Panduit Waterfall Trough for PR2V Managers in a sleek, durable black finish. This over-rack pathway is engineered to route cables efficiently into the vertical manager channel while preserving bend radii and reducing clutter. The Waterfall Trough is designed to grow with your infrastructure, expanding to accommodate both Panduit 2-post and 4-post racks. With a focus on clean cable management, easy accessibility, and robust construction, this trough helps you achieve organized, scalable, and service-friendly cabling environments.
- Over-rack pathway that guides cables into the PR2V vertical manager channel, maintaining controlled bend radii to protect conductors and improve reliability.
- Expandable design compatible with Panduit 2-post and 4-post racks, enabling you to tailor the trough length to your specific installation without replacing components.
- Durable black powder-coated steel construction combines rugged performance with a professional, low-profile appearance suitable for data centers, server rooms, and network closets.
- Seamless integration with the PatchRunner family and Panduit cable management offerings to deliver a cohesive, high-density cabling solution with improved airflow and accessibility.
- Enhances serviceability by organizing cable routes, reducing migration time during maintenance, and helping prevent cable damage caused by abrasion or improper routing.
Technical Details of Panduit Waterfall Trough for PR2V Managers, Black
- Material: Durable steel with black powder-coated finish for corrosion resistance and long-lasting wear in data center environments.
- Color/Finish: Black to blend with standard rack aesthetics and minimize visual clutter within IT spaces.
- Design: Over-rack waterfall trough that creates a defined, expandable cable pathway into the vertical manager channel.
- Compatibility: Suitable for Panduit PR2V PatchRunner managers and compatible with both 2-post and 4-post rack configurations.
- Expansion: Fully adjustable length to fit varying rack depths and mounting scenarios without requiring additional hardware.
- Routing: Engineered to maintain proper bend radii for multi-pair, fiber, and power cabling, helping to preserve signal integrity and reduce wear.
- Mounting: Engineered mounting interface designed for secure attachment to rack structures, offering stable support for dense cable runs.
- Applications: Ideal for data centers, network closets, and labs that demand organized, scalable cable management with professional aesthetics.
how to install Panduit Waterfall Trough for PR2V Managers, Black
Follow these general steps to install the Panduit Waterfall Trough with PR2V managers on compatible Panduit racks. Always refer to your specific rack and trough model instructions for precise hardware requirements and safety considerations.
- Verify compatibility: Confirm that your rack is a Panduit 2-post or 4-post system and that the PR2V manager is installed or planned for the corresponding rack.
- Prepare the rack: Ensure the rack is clean, level, and capable of supporting the additional weight of the trough and routed cables. Remove any obstructions that could interfere with mounting.
- Measure and configure: Determine the required trough length for your installation. If the trough is expandable, extend it to the desired length while ensuring smooth, even sections to prevent sharp bends.
- Mounting location: Position the waterfall trough to align with the front edge or designated mounting plane of the rack, ensuring that the pathway will channel cables into the vertical manager without interference with doors, panels, or other hardware.
- Attach hardware: Use the provided mounting hardware to secure the trough to the rack according to the manufacturer’s guidelines. Tighten bolts or screws to a secure but not over-tightened state to avoid warping.
- Route cables: Begin guiding cables into the trough from the over-rack entry point, maintaining appropriate bend radii and separation between power and data cables. Leave sufficient slack for future changes and maintenance.
- Connect to PR2V: Align the trough’s outlet with the PR2V vertical manager channel. Verify that the cables enter the vertical path cleanly and that there is no excessive strain on connectors.
- Final checks: Confirm that the overall cabling layout is organized, that airflow around the trough remains unobstructed, and that all connections are secure. Perform a brief functional check to ensure channels route correctly and signals aren’t degraded by improper bends.
Frequently asked questions
-
Q: What racks are compatible with the Panduit Waterfall Trough for PR2V Managers?
A: The trough is designed to be expandable and compatible with Panduit 2-post and 4-post racks, providing an over-rack pathway into the PR2V vertical manager channel. -
Q: What materials are used in construction?
A: It features a durable steel core with a black powder-coated finish to withstand data center environments and resist corrosion. -
Q: Does the trough affect cable bend radii?
A: No. The trough is engineered to preserve proper bend radii, protecting cables from kinks and reducing wear over time. -
Q: Can I adjust the length after installation?
A: Yes. The Waterfall Trough is expandable, allowing length adjustments to fit a range of rack depths without replacing components. -
Q: Will this trough improve airflow?
A: By organizing cables and reducing clutter, the trough helps improve airflow management around the rack, supporting better overall cooling efficiency.