Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 600mm enclosures.


Price:
Sale price$3,338.88

Description

Rack Air Removal Unit SX 100-240V 50/60Hz for NetShelter 600mm Enclosures

Maximize cooling efficiency in densely packed NetShelter racks with the Rack Air Removal Unit SX. This compact, high-performance accessory is designed to capture exhausting hot air from tightly populated enclosures, redirect it back into the plenum, and prevent heat from building up where conventional airflow methods fall short. In modern data centers and server rooms, dense equipment configurations can trap heat and create hotspots that compromise performance and uptime. The Rack Air Removal Unit SX tackles these challenges head‑on by delivering targeted air management that enhances cooling reliability, reduces equipment wear, and contributes to lower overall energy use. Engineered for 600mm-wide NetShelter enclosures, the SX model combines versatile voltage compatibility with robust construction to meet the demanding needs of today’s IT environments.

When you deploy the Rack Air Removal Unit SX, you’re choosing a solution that aligns with best practices in data center cooling. The unit works by capturing the elevated temperatures generated by servers, storage devices, and networking gear, then returning the heated air to the enclosure’s plenum where it can be reconditioned by the room’s cooling system. This controlled recirculation minimizes the formation of hotspots and reduces the workload on fans and cooling units, helping to maintain consistent inlet air temperatures across critical equipment. The result is improved equipment reliability, enhanced performance during peak loads, and a more predictable thermal profile for your NetShelter infrastructure. By integrating seamlessly with 600mm enclosure configurations, the SX unit preserves cabinet density while expanding the effectiveness of your existing cooling strategy.

The Rack Air Removal Unit SX is built to withstand the rigors of data center operation. Its sturdy construction and straightforward mounting options make it suitable for a wide range of installation scenarios, from small server rooms to larger colocation facilities. Its design emphasizes reliability and ease of use, with a compact footprint that fits cleanly behind or alongside racks and does not interfere with cable management or access. In addition to improving thermal performance, the unit helps reduce operational noise by targeting airflow more precisely where it’s needed, contributing to a more comfortable working environment for IT staff and technicians. For administrators seeking a scalable solution, the SX unit provides a practical path to better airflow management without requiring a major overhaul of existing cooling infrastructure.

Ultimately, the Rack Air Removal Unit SX for NetShelter 600mm enclosures is about proactive thermal control. It helps maintain stable temperatures during high-heat events, supports longer hardware lifespans, and delivers measurable improvements in cooling efficiency. The combination of dense airflow management, compatible voltage range (100-240V, 50/60Hz), and durable construction makes the SX a compelling choice for organizations that value uptime and performance in their rack environments. This product embodies a balanced approach to air handling: it recovers heat that would otherwise circulate through equipment interiors and reintroduces it into the plenum for a more uniform, controlled cooling process. If your goal is to minimize hotspots, reduce energy waste, and protect critical IT assets in densely populated NetShelter enclosures, the Rack Air Removal Unit SX stands out as a practical and effective option.

  • Optimizes airflow in densely packed racks by capturing exhaust heat and returning it to the plenum, reducing hotspot formation and promoting uniform temperatures across equipment.
  • Specifically designed for NetShelter 600mm enclosures, ensuring a snug fit, unobtrusive installation, and compatibility with existing cooling strategies.
  • Operates on a universal 100-240V AC supply with 50/60Hz compatibility, offering flexible installation across global data-center environments without the need for special transformers.
  • Easy installation and maintenance with minimal tools required, allowing quick integration into current rack configurations and straightforward access for service checks.
  • Durable construction and quiet operation, engineered to withstand continuous data-center use while delivering reliable air-removal performance over the long term.

Technical Details of Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 600mm enclosures

  • Model: SX Rack Air Removal Unit
  • Voltage: 100-240V AC
  • Frequency: 50/60 Hz
  • Compatibility: NetShelter 600mm enclosure width
  • Function: Captures exhaust heat and returns it to the enclosure plenum
  • Construction: Durable metal housing with mounting hardware
  • Application: Dense rack environments seeking improved thermal management

How to install Rack Air Removal Unit SX

  • Assess compatibility: Confirm that your NetShelter enclosure is 600mm wide and that your power availability matches the SX’s 100-240V AC, 50/60Hz specification.
  • Power down and safety check: Shut off equipment and verify there is no live power in the installation area before beginning installation.
  • Mounting location: Determine an appropriate mounting position on the rear or side of the NetShelter enclosure where exhaust heat can be efficiently captured without obstructing cable management or doors.
  • Secure the unit: Use the supplied mounting hardware to fasten the Rack Air Removal Unit SX to the enclosure frame. Ensure it is level and firmly attached to prevent vibration or displacement during operation.
  • Connect power: Plug the unit into a suitable power source. Route cables so they do not interfere with airflow paths or access panels. If needed, use cable ties or management channels to keep wiring tidy and out of the air stream.
  • Integrate into cooling strategy: Confirm that the unit’s operation supports your overall cooling plan (hot aisle/cold aisle alignment, room cooling capacity, and any supplementary cooling devices).
  • Test and verify: Restore power, power on the enclosure, and monitor airflow and temperatures to verify the SX unit is capturing exhaust heat and delivering it back into the plenum as designed.

Frequently asked questions

  • What does the Rack Air Removal Unit SX do? It captures the exhaust heat generated by densely packed IT equipment and returns it to the enclosure plenum, helping to prevent hotspots and improve overall cooling efficiency.
  • What enclosures is it compatible with? It is designed for NetShelter 600mm enclosure widths, providing a precise fit and optimized airflow within that form factor.
  • What voltage and frequency does it require? The SX supports 100-240V AC at 50/60 Hz, making it suitable for global deployment without additional transformers.
  • Is installation difficult? No. It is designed for straightforward mounting on NetShelter enclosures and uses standard hardware. Basic hand tools are typically sufficient for installation.
  • Will it reduce noise or energy use? By improving targeted airflow and reducing hotspots, it can contribute to lower fan speeds and more efficient cooling, which may lower energy use and potentially reduce audible noise from cooling equipment.
  • Can I retrofit it into an existing installation? Yes, provided there is adequate space and a 600mm NetShelter enclosure. Ensure proper clearance for airflow and access for future maintenance.