Description
The Raritan 18-Outlets PDU delivers dependable, scalable power distribution for data centers, server rooms, labs, and high-density IT environments. Engineered for reliability and efficiency, this 0U rack-mountable power distribution unit combines precise power control with real-time load monitoring to help you optimize uptime and energy use. With a 230 V AC input and a formidable 8600 W total capacity, it supports demanding workloads while maintaining safe, organized, and accessible power delivery. Its thoughtful outlet mix—12 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles—offers flexible connections for a wide range of equipment, from rack servers to network gear and storage devices. The NEMA L21-30P plug ensures a secure, locking connection suitable for environments requiring reliable 230 V power distribution, and the 0U design saves valuable rack space without compromising performance or serviceability. In short, this PDU is built to simplify data-center power management, improve reboot procedures, and give IT teams the visibility needed to keep systems running smoothly.
- Massive outlet capacity: 18 outlets in a compact 0U form factor, including 12 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles, enabling flexible connections for servers, switches, storage, and other critical devices. This blend supports mixed equipment footprints and helps consolidate power cables for cleaner, cooler racks while preserving easy access for maintenance and upgrades.
- Secure, versatile power input: NEMA L21-30P plug provides a robust, locking connection for 230 V three-phase-friendly power distribution. The locking design minimizes the risk of accidental unplugging in busy racks, maintaining uninterrupted power delivery for essential equipment and simplifying rack wiring in demanding environments.
- Remote power control: Integrated remote controlled relay enables power-on/power-off control of outlets or grouped banks, enabling smart reboot sequences, maintenance mode, and remote power management without on-site visits. This capability reduces downtime during software updates or hardware replacements and supports automated scripts for consistent maintenance workflows.
- Live load monitoring: Real-time visibility into current, voltage, and power usage per outlet or bank, empowering operators to optimize energy efficiency and prevent overloads. With proactive monitoring, you can identify power-hungry devices, balance loads across phases, and plan capacity for future growth while maintaining reliability across the rack.
- Rack-ready and space-efficient: 0U, 19-inch rack-capable design maximizes space in dense data centers and labs. The sturdy metal housing and standard mounting rails support clean installation in shared racks, with cable management considerations that help maintain airflow, reduce clutter, and simplify serviceability.
Technical Details of Raritan 18-Outlets PDU
- Power input/output: 230 V AC, up to 8600 W total
- Outlets: 12 x IEC 60320 C13, 6 x IEC 60320 C19
- Plug type: NEMA L21-30P
- Form factor: 0U rack-mountable
- Monitoring: remote controlled relay with load monitoring capabilities
- Mounting: 19-inch rack-compatible, 0U profile
how to install Raritan 18-Outlets PDU
Installing the Raritan 18-Outlets PDU is designed to be straightforward, with a focus on safety, reliability, and ease of maintenance. Before you begin, confirm that your rack space is compatible with a 19-inch, 0U PDU and that your facility electrical service can supply 230 V at the required current. Prepare your workspace by organizing cables and labeling outlets to support efficient management after deployment. Follow these steps to install and configure the PDU for optimal performance:
- Power down equipment in the rack and disconnect devices to prevent accidental energization during installation. This helps protect both personnel and equipment from electrical hazards.
- Mount the PDU horizontally into the rack using the included hardware. Ensure the chassis is securely fastened and seated in the rack rails, with no wobble that could affect stability or airflow.
- Connect the PDU’s NEMA L21-30P plug to a suitable 230 V power source. Verify that the input supply can deliver the required current and that the connection is secure to avoid arcing or loosening under load.
- Route and organize the connected equipment cables to the IEC C13 and C19 outlets. Label critical devices for easy reboot or maintenance, and consider using cable management accessories to preserve airflow and reduce heat buildup.
- Power on the PDU and configure the remote relay controls and load monitoring thresholds through the management interface or supported software. Test a controlled power cycle of selected outlets to verify correct operation and ensure devices respond as expected.
Frequently asked questions
- What outlets are included on the Raritan 18-Outlets PDU? It includes 12 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles, designed to accommodate a mix of servers, storage devices, and networking gear.
- What is the maximum power capacity? The PDU supports up to 8600 W total at 230 V, providing ample headroom for high-density racks and peak load scenarios.
- What type of plug is used? It uses a NEMA L21-30P input plug, ensuring a secure, locking connection appropriate for 230 V environments.
- Does it support remote monitoring? Yes, it features a remote controlled relay and load monitoring, enabling centralized control and visibility over energy usage.
- Is this PDU rack-mountable? Yes, it is designed for 0U mounting in standard 19-inch racks, helping you maximize space efficiency without sacrificing accessibility.