Description
Raritan 8-Port Dual Head SecureSwitch with NIAP PP4.0 Certification and CAC Support
The Raritan 8-Port Dual Head SecureSwitch is a government-grade peripheral sharing solution designed for environments where security, isolation, and controlled access are non-negotiable. Built to meet NIAP PP4.0 certification requirements, this device enables authorized personnel to securely access multiple computers without compromising data integrity or network separation. Featuring DisplayPort (DP) dual-head output and CAC (Common Access Card) support, it is ideal for agencies, defense contractors, and intelligence operations that demand rigorous access control, robust audit trails, and dependable performance under demanding workloads.
- NIAP PP4.0 certified peripheral sharing ensures that the SecureSwitch undergoes rigorous security evaluation to validate its ability to isolate host systems, prevent cross-contamination of data, and enforce strict access control. This certification translates into auditable enforcement of security policies, tamper-evident hardware design, and consistent compliance with government and defense standards. For organizations handling sensitive information, this certification provides confidence that a hardware-based solution is safeguarding user sessions and data paths from end to end.
- 8-port dual-head configuration delivers scalable, secure access across two independent workstations or users while maintaining strict isolation between connected host machines. Each of the eight ports supports dual-head video, enabling high-clarity displays and simultaneous session management without compromise. The dual-head architecture is particularly valuable in environments where operators must monitor multiple systems or where red-team/blue-team operations require rapid switching between hosts while preserving environment separation and control over user permissions.
- DisplayPort (DP) support for high-resolution visuals provides sharp, reliable video performance essential for data-intensive tasks, engineering graphics, and diagnostic workflows. DP interfaces offer robust bandwidth, support for multiple displays, and enhanced color fidelity, enabling operators to view complex datasets, dashboards, and real-time telemetry clearly. This DP capability aligns with modern workstations commonly deployed in both government and enterprise settings, reducing the need for adapters or converters and preserving signal integrity across longer cable runs.
- CAC authentication and secure login streamline credential-based access for authorized personnel. By integrating CAC-based authentication, the SecureSwitch enforces strong identity verification before any console or peripheral sharing occurs. This feature helps organizations satisfy personnel security requirements, minimize the risk of unauthorized access, and support compliant account management with auditable login events tied to individual users.
- Auditable security with centralized management includes built-in logging, session tracking, and policy enforcement that align with regulatory mandates. The device supports detailed event histories, access control lists, and configuration records that facilitate thorough investigations and compliance reporting. The combination of NIAP validation, CAC support, and robust audit capabilities makes the SecureSwitch a reliable cornerstone for secure workstation access in high-security environments.
Technical Details of Raritan 8-Port Dual Head SecureSwitch
Note: Technical details are drawn from official product specifications and security documentation. For precise configuration parameters (ports, interfaces, firmware versions, and environmental ratings), consult the vendor’s latest data sheets and deployment guides;
- Certification: NIAP PP4.0 certified peripheral sharing switch designed for high-assurance environments. This ensures adherence to security-enforced partitioning between connected systems and robust protection against data leakage across sessions.
- Ports and connectivity: 8-port peripheral sharing with dual-head DisplayPort video outputs. Designed to accommodate two independent workstations or two concurrent user sessions, with secure, isolated paths for display, input, and peripheral signals between hosts and shared devices.
- Display technology: DisplayPort-based video channels that support high-resolution output and reliable color representation. DP interfaces are chosen for their bandwidth, stability, and compatibility with modern monitors used in government and enterprise settings.
- Security and access control: CAC support for smart-card based authentication, role-based access policies, and hardened session initiation to ensure that only authorized users can initiate and maintain connections to the shared peripherals.
- Audit and compliance features: Comprehensive logging of session activity, access events, and configuration changes to facilitate forensics, audits, and regulatory reporting. These capabilities are designed to meet strict containment and traceability requirements common in sensitive operations.
- Hardware and reliability: Tamper-evident design with hardened enclosure, secure mounting options, and compatibility with standard data-center power and environmental control systems. The device emphasizes low-latency switching and consistent performance under load to support critical mission tasks.
- Management and interoperability: Centralized management interfaces and compatibility with existing security policies and provisioning workflows. The SecureSwitch is intended to integrate smoothly with established government and contractor IT ecosystems, minimizing operational friction during deployment.
How to install Raritan 8-Port Dual Head SecureSwitch
Installing the Raritan 8-Port Dual Head SecureSwitch is designed to be straightforward while preserving the security posture required in high-assurance environments. The following steps outline a secure, compliant deployment approach that aligns with NIAP guidelines and CAC-enabled workflows.
- Prepare and verify security prerequisites: Ensure you have the necessary authorization, CAC credentials, and user provisioning data. Confirm that you are operating in a controlled environment with approved cabinets, power conditioning, and access to the SecureSwitch for installation and initial configuration. Verify that firmware and security policies are up to date and aligned with your agency’s compliance requirements.
- Connect host devices and peripherals: Connect the eight host computers or workstations you intend to share to the SecureSwitch’s 8-port interface, ensuring correct port mapping according to your deployment plan. Attach the dual-head DisplayPort cables to the appropriate DP outputs for each workstation, and route keyboards, mice, and any required USB peripherals through the switch’s USB paths as defined by your security policy. Keep data cables organized and labeled to support rapid auditing and troubleshooting.
- Attach displays and test video paths: Connect the display(s) to the DisplayPort outputs on the SecureSwitch. Power on the devices and verify that each host’s video signal is correctly routed to its assigned monitor(s). Confirm that resolution and refresh rates meet the operational requirements and that no cross-talk or signal degradation is evident across the 8-port configuration.
- Enable CAC-based access and policy enforcement: Ensure CAC readers (internal or external, as configured) are recognized by the system and that user accounts with CAC credentials are provisioned. Configure access policies to enforce authentication at session start, and set up any required role-based access controls (RBAC) for different user groups. Validate that sessions terminate or automatically logout when an authorized user ends a session or when access conditions change.
- Configure audit logging and security policies: Enable and tailor the audit logging features to capture essential events such as session initiations, terminations, CAC authentications, policy changes, and any anomaly events. Establish log retention periods, secure log storage locations, and alert mechanisms for rapid detection and response to security events.
- Perform a security validation sweep: Run a validation checklist to confirm that NIAP PP4.0 controls, isolation between hosts, and CAC-based access controls function as intended. Validate that switching occurs with minimal latency, that no data paths cross between isolated hosts, and that logs accurately reflect user actions and session metadata. Document the results for compliance records and future audits.
- Finalize deployment and provide user training: After successful testing, finalize the cabling, labeling, and operational documentation. Deliver end-user training focusing on secure usage practices, access controls, and incident reporting. Establish ongoing maintenance routines, including firmware updates, policy reviews, and periodic security assessments aligned with the organization’s risk management framework.
Frequently asked questions
- Q: What is NIAP PP4.0 certification? A: NIAP PP4.0 is a government-designed security evaluation standard that validates a product’s ability to enforce strong access control, isolation between connected systems, and auditable operation in high-security environments. A device with NIAP PP4.0 certification provides documented assurance to agencies and contractors that it meets stringent security requirements for peripheral sharing and session management.
- Q: Does the Raritan 8-Port Dual Head SecureSwitch support CAC authentication? A: Yes. The SecureSwitch includes CAC (Common Access Card) support, enabling smart-card–based authentication to securely authorize user access before any shared peripherals or displays are engaged. This feature is critical for meeting personnel security and identity verification mandates in government and defense contexts.
- Q: How many ports are available, and what does “dual head” mean in this product? A: The device provides eight ports for connecting host computers. “Dual head” refers to the capability of supporting two independent DisplayPort display paths per configured session or two distinct workstations, enabling operators to manage multiple hosts with dedicated video outputs while preserving strict separation of sessions.
- Q: Can I rely on this switch for mission-critical performance? A: Yes. The SecureSwitch is designed for high-security environments where reliability, predictable latency, and consistent video and I/O performance are essential. It emphasizes secure, tamper-evident hardware, robust power and signaling, and deterministic switching behavior to support mission-critical workloads.
- Q: How do I validate and maintain NIAP compliance after deployment? A: Maintain NIAP compliance by applying approved firmware updates, enforcing configured security policies, maintaining CAC enrollment, and conducting periodic security audits. Preserve detailed logs and ensure that every session begins with authenticated access and that all access events are auditable for regulatory reporting.
Customer reviews
Showing - Of Reviews