Raritan Dominion PX-2000 PX2-2147R 8-Outlets 1.9kVA PDU

RaritanSKU: 4814341

Price:
Sale price$810.97

Description

Raritan Dominion PX-2000 PX2-2147R 8-Outlets 1.9kVA PDU

The Raritan Dominion PX-2000 PX2-2147R is a high-performance intelligent power distribution unit designed for demanding data centers, server rooms, and network closets. Built to deliver precise, reliable power control, this 8-outlet PDU combines robust hardware with smart management features to simplify energy oversight, improve device uptime, and optimize rack efficiency. With a 1.9 kVA rating, it provides steady headroom for mid-range IT loads while offering scalability as your infrastructure grows. The PX-2000 series stands out for its flexibility, supporting multiple mounting options and a wide array of receptacle configurations so you can tailor power delivery to your exact equipment mix without compromising space or performance.

  • 8-powered outlets with scalable capacity

    Equipped with eight outlets, the PX-2000 PX2-2147R delivers distributed power to rack-mounted servers, storage devices, switches, and other critical equipment. The 1.9 kVA rating provides ample headroom for modern IT workloads, enabling safe, efficient distribution without overloading individual circuits. This balance between capacity and density helps you consolidate power management in a single, centrally managed unit, reducing clutter and improving maintenance workflows.

  • Flexible mounting: Zero U and 1U form factors

    The PX-2000 series is engineered for adaptability in tight rack spaces. It is available in Zero U (vertical-mount) and 1U (horizontal-mount) configurations, allowing you to choose the orientation that best fits your rack layout and cable management strategy. Whether you’re retrofitting a dense data hall or outfitting a compact network cabinet, this PDU integrates cleanly with your existing rails and peripherals while preserving airflow and organization.

  • Outlet-level switching for granular control

    One of the key advantages of the Dominion PX-2000 is outlet-level switching. This capability lets you remotely power-cycle individual outlets, automate scheduled reboots, and implement precise load sequencing for equipment during maintenance windows. Outlet-level control minimizes the need for physically accessing each device, speeds up fault isolation, and helps preserve uptime across the entire rack ecosystem.

  • Broad receptacle configurations for diverse IT environments

    The PX-2000 family embraces a broad range of NEMA, IEC, and other receptacle configurations to fit diverse regional requirements and equipment footprints. With models designed to accommodate high-power distribution scenarios—including variants that support 400V input options—you can align power delivery with your devices’ specific plug types while maintaining code-compliant installation practices. This versatility reduces the need for adapters and extra cables, streamlining deployment.

  • Intelligent management and monitoring features

    Beyond physical power distribution, the PX-2000 provides robust management capabilities that give operators real-time visibility and remote control. Expect metered measurements of voltage, current, and power, plus energy usage reporting and event logging. Web-based management and SNMP compatibility enable proactive monitoring, alerting, and integration with data-center infrastructure management (DCIM) systems. With these features, you can optimize energy use, plan capacity, and enforce maintenance schedules with confidence.

Technical Details of Raritan Dominion PX-2000 PX2-2147R

  • Model

    PX2-2147R — part of the PX-2000 intelligent PDU family designed for flexible power distribution in rack environments.

  • Outlets

    8 outlets configured to support distributed devices throughout a standard server rack, enabling centralized power management for multiple devices from a single unit.

  • Power rating

    1.9 kVA capacity, providing adequate headroom for mid-range IT loads while maintaining efficiency and load balance across outlets.

  • Form factor

    Offers Zero U vertical-mount and 1U horizontal-mount configurations to suit different rack layouts and cabling strategies.

  • Receptacle configurations

    Supports a variety of plug types, including NEMA and IEC receptacles, with configurations designed to match regional standards and hardware footprints. Some PX-2000 variants also accommodate higher-power distributions where required.

  • Outlet switching

    Individual outlet switching enables remote power control, maintenance automation, and orderly device reboots without onsite visits, reducing mean time to repair and improving overall uptime.

  • Management and monitoring

    Built-in intelligence supports web-based management and remote monitoring via SNMP, with real-time metering (voltage, current, and energy) and event logs to assist with capacity planning, reporting, and compliance.

How to Install Raritan Dominion PX-2000 PX2-2147R

  • Plan the installation

    Assess your rack space, determine whether to mount the PX-2000 in Zero U vertical orientation or 1U horizontal orientation, and identify the preferred receptacle configurations for your equipment mix. Ensure you have adequate clearance for cable management and airflow to maximize cooling efficiency.

  • Mount in the rack

    Secure the PDU to the rack using the included rails or mounting hardware compatible with your rack system. Align outlets with anticipated device locations and route power and data cables to minimize crossovers and turbulence around airflow paths.

  • Connect input power

    Connect the PDU’s input power cord to a properly rated mains supply that matches the unit’s specifications. Verify voltage, phase, and amperage to prevent overloads and ensure safe, reliable operation. If you’re integrating into a high-density or high-variance environment, consider a redundant or buffered power feed where appropriate.

  • Attach devices and distribute load

    Plug your servers, switches, storage arrays, and other equipment into the eight outlets. Distribute critical devices across outlets to minimize the risk of simultaneous outages, and avoid overloading any single outlet where possible. Keep high-draw devices on distinct outlets to facilitate targeted power-control actions during maintenance.

  • Configure management

    Connect to the PX-2000’s management interface via its web portal or your existing DCIM system. Assign a static IP address, configure user access, enable SNMP if required, and set up alert thresholds for voltage, current, and energy usage. Enable outlet-level switching policies and schedule reboot sequences to automate routine maintenance without manual intervention.

  • Test and verify

    Run a comprehensive test by cycling selected outlets, validating metering readings, and confirming that alerts and logs are generated correctly. Confirm that remote management functions, such as firmware updates and event reporting, operate as intended. Document the configuration for future reference and compliance audits.

Frequently Asked Questions

  • Q: What does the PX-2000 PX2-2147R provide?

    A: It is an 8-outlet intelligent PDU with a 1.9 kVA rating, designed to deliver centralized, monitorable power distribution in rack environments. It supports flexible mounting options and outlet-level switching for granular control and maintenance efficiency.

  • Q: Can I mount this PDU in Zero U or 1U form factors?

    A: Yes. The PX-2000 series offers both Zero U vertical-mount and 1U horizontal-mount configurations, giving you the flexibility to optimize space, cabling, and airflow in your rack design.

  • Q: Does it support outlet-level switching?

    A: Yes. The PX-2000 enables remote control of individual outlets, enabling automated reboots, maintenance windows, and orderly load management without direct physical access to devices.

  • Q: What receptacle configurations are available?

    A: The PX-2000 family uses a broad range of receptacle configurations, including NEMA and IEC types. Depending on the exact model, high-power options (such as 400V variants) may be available to fit regional electrical standards and device requirements.

  • Q: How is the PDU managed?

    A: Management is delivered through a web-based interface and SNMP. It provides real-time metering, event logs, and alerting to facilitate energy management, capacity planning, and integration with data-center management systems.

  • Q: Is professional installation required?

    A: Many installations can be completed by IT staff or facilities teams using standard rack-mount procedures. Always follow local electrical codes and the manufacturer’s installation guide to ensure safety and compliance.