Raritan Dominion PX-2000 PX2-2476 24-Outlets 1.9kVA PDU

RaritanSKU: 5596832

Price:
Sale price$1,427.40

Description

Raritan Dominion PX-2000 PX2-2476 24-Outlets 1.9kVA PDU

Designed for demanding data centers, server rooms, and network closets, the Raritan Dominion PX-2000 PX2-2476 24-Outlets 1.9kVA PDU delivers precise power distribution with intelligent control. The PX-2000 series is engineered to support modern rack architectures through flexible mounting options—Zero U vertical and 1U horizontal—allowing you to optimize space while maintaining easy access to all outlets. With 24 outlets and a robust 1.9 kVA rating, this PDU provides scalable power distribution for dense racks, helping you manage loads, ensure uptime, and streamline operations. The PX-2000 supports outlet-level switching, enabling granular power management for individual devices, automated cycles, and energy-saving strategies. Paired with comprehensive monitoring and remote management capabilities, it transforms power from a passive necessity into an active, data-driven part of your IT infrastructure.

  • 24 outlets with a 1.9 kVA rating: Scalable power distribution to support dense rack deployments and high-density equipment without compromising reliability.
  • Individual outlet switching: Control, monitor, and power-cycle each outlet independently for targeted maintenance, problem isolation, and uptime optimization.
  • Flexible form factors: Choose Zero U vertical mounting or 1U horizontal mounting to fit your rack configuration and space constraints.
  • Broad receptacle compatibility: Availability in a variety of NEMA and IEC configurations, including options suitable for high-power 400V distributions.
  • Remote management and analytics: Centralized monitoring, alerts, and energy usage data via integrated management interfaces to optimize efficiency and predict issues before they impact operations.

Technical Details of Raritan Dominion PX-2000 PX2-2476 24-Outlets 1.9kVA PDU

  • Model: PX2-2476 (24-Outlets, 1.9 kVA)
  • Series: PX-2000
  • Form factor: Zero U (vertical) and 1U (horizontal) options to fit both compact and traditional rack layouts
  • Power rating: 1.9 kVA (total, varies with input voltage and configuration)
  • Input voltage and frequency: Typically supports 100–240 VAC, 50/60 Hz operation (model-dependent)
  • Outlets: 24 outlets configured to accommodate a range of receptacle types (NEMA/IEC) aligned with the chosen model
  • Outlet switching: Individual outlet control to enable selective power cycling and granular management
  • Remote management: Integrated capability for remote monitoring and control via standard interfaces (web UI, SNMP/management software compatibility)
  • Construction: Durable rack-mount enclosure designed for reliability in rack environments

How to install Raritan Dominion PX-2000 PX2-2476 24-Outlets 1.9kVA PDU

Prepare your rack and plan the installation by identifying whether you will deploy the PDU in Zero U vertical orientation or 1U horizontal placement. Confirm that your rack has the necessary mounting rails and clearance to ensure accessible outlets and serviceability. If you are upgrading from a prior PDU, map the devices to their corresponding outlets so you can maintain an organized topology from day one.

Step 1 — Choose the correct form factor and receptacles: Select Zero U or 1U configuration based on your rack footprint and port access requirements. Verify the outlet type configuration that matches the devices you intend to power, ensuring compatibility with NEMA or IEC receptacles as applicable to your environment.

Step 2 — Mount the PDU in the rack: Use the provided mounting brackets or rails to secure the PDU to the rack rails. Ensure the unit is level and firmly fastened to prevent movement during maintenance or cable management. Leave sufficient space for cooling and for accessing the outlets. If you are using Zero U installation, ensure the vertical pathway aligns with your rack’s internal structure and does not obstruct other components.

Step 3 — Connect the input power: Connect the PDU to the appropriate power source, following local electrical codes and your data center power distribution plan. Use the correct input connector, power cable, and protection (such as appropriate circuit breakers) as required by your facility. Do not exceed the stated input voltage or current rating of the PDU.

Step 4 — Arrange and connect device cables: Attach each device to its designated outlet. Use color-coding or labeling to simplify future maintenance and reduce the risk of miswiring during replacements or reconfigurations. Route cables to minimize airflow obstruction and to reduce strain on outlets and connectors.

Step 5 — Power up and configure the PDU: Apply power and verify that the PDU boots correctly. Access the PDU’s management interface via the built-in web UI or your preferred management software. Configure outlet groups, access credentials, alarm thresholds, and any power-cycling policies you plan to implement. If required, enable SNMP, syslog, or API integrations to feed data into your centralized monitoring environment.

Step 6 — Validate operation and capacity planning: Confirm that all outlets power devices as expected and that the monitoring data reflects real-time load, voltage levels, and energy consumption. Use this information to refine capacity planning, set alerting rules, and implement power capping or load-shedding strategies to protect critical equipment during power events.

For ongoing maintenance, document outlet assignments, periodically review load distribution across outlets, and ensure firmware or software components stay up to date with the latest releases from Raritan. Maintain best practices for cable management and keep the PDU’s environment free from dust and excessive heat to preserve reliability over the life of the equipment.

Frequently asked questions

Q: What is the Raritan Dominion PX-2000 PX2-2476 designed for?

A: It is a 24-outlet, 1.9 kVA PDU built for enterprise racks, offering outlet-level switching, flexible mounting options, and remote management to optimize power distribution, monitoring, and uptime in data centers, labs, and network closets.

Q: What mounting options does it support?

A: The PX-2000 series supports both Zero U vertical mounting and 1U horizontal mounting, enabling flexible integration into various rack configurations and saving valuable space in dense deployments.

Q: Can I manage this PDU remotely?

A: Yes. The PX-2000 offers remote management capabilities, including a web-based interface and compatibility with standard management protocols, which enables monitoring of voltage, current, power, and energy consumption, plus outlet-level control and alerting.

Q: What receptacle configurations are available?

A: The PX-2000 PX2-2476 line provides a selection of NEMA and IEC outlet configurations to match the devices in your environment, including high-power options suitable for 400V distributions where supported by the model.

Q: How does outlet-level switching benefit operations?

A: Outlet-level switching allows you to remotely power-cycle or disable individual outlets, facilitating targeted maintenance, reducing downtime, and enabling more precise management of workloads and energy use within your rack.