Raritan PX3-5405V 20-Outlets PDU

RaritanSKU: 5389119

Price:
Sale price$1,630.65

Description

Raritan PX3-5405V 20-Outlets PDU

The PX3-5405V is a high‑value, intelligent rack PDU from Raritan designed to transform how you manage power in data centers, server rooms, and edge deployments. It brings real‑time visibility, precise energy analytics, and granular control to your IT infrastructure, helping you optimize uptime, reduce energy waste, and simplify budgeting. With 20 outlets in a compact 1U footprint, this PDU fits neatly into standard 19-inch racks while delivering powerful monitoring and automation features that scale with your evolving needs.

At the core of the PX3 family is meticulous power measurement. The PX3-5405V provides real‑time remote monitoring of current (amps), voltage, and overall power consumption expressed as kilowatts (kW) or kilovolt-amperes (kVA), along with energy usage tracked in kilowatt-hours (kWh). What makes it particularly compelling for IT and facilities teams is its billing‑grade accuracy of +/- 1%, achieved at the level of individual outlets. This level of precision makes chargebacks and capacity planning reliable, enabling finance and operations teams to allocate costs accurately, forecast future power needs, and identify inefficiencies before they affect service levels. In practice, this means you can correlate equipment up/down states with actual energy usage, identify hungry devices, and implement smarter power capping or workload placement strategies.

Beyond measurement, the PX3-5405V empowers you with comprehensive control and automation. You can remotely switch outlets on and off, schedule power cycles, and apply outlet‑level policies to accommodate start-up sequences and maintenance windows. Outlet‑level control is especially valuable in complex racks where different devices have varying power profiles, enabling you to minimize inrush, reduce thermal hotspots, and extend equipment life. Pair these capabilities with proactive alerting, and your team receives timely notifications when thresholds are breached—long before an outage disrupts critical services. This combination of visibility, control, and automation helps you reduce mean time to repair, improve reliability, and maintain service levels without manual, on-site intervention.

The PX3‑5405V is designed for networked operations and centralized management. It includes a robust web-based user interface for on‑box configuration and day‑to‑day monitoring, plus support for industry standards such as SNMP for integration with DCIM and monitoring platforms. Secure access options help protect sensitive control functions, and you can configure events and alarms that trigger when amperage, voltage, or energy usage cross predefined thresholds. This makes it easy to build a unified power management strategy across multiple racks or data centers, with dashboards, reports, and historical data that inform capacity planning, energy procurement, and sustainability initiatives. Whether you’re monitoring a single rack or an entire data center, the PX3‑5405V provides a scalable, future‑proof foundation for intelligent power management.

From a physical and operational perspective, the PX3‑5405V is engineered to slot into standard IT environments with minimal disruption. It is built to endure the demands of continuous operation in data centers and enterprise IT spaces, delivering reliable power distribution with clear outlet labeling and straightforward cable management. Its 20 outlets are arranged to maximize accessibility within a typical rack, and the 1U form factor preserves precious rack space for servers, storage, and network gear. For IT teams pursuing sustainability or cost-control goals, the PX3‑5405V’s comprehensive metering and reporting capabilities provide actionable insights—supporting energy-aware decision making and helping you document progress toward efficiency targets and green IT standards.

  • Real‑time monitoring at outlet level: Tracks current (amps), voltage, power (kW/kVA), and energy (kWh) for every outlet with billing‑grade accuracy to within +/- 1%, enabling precise chargebacks, detailed usage analytics, and smarter capacity planning.
  • Outlet‑level control and scheduling: Remotely power cycle individual outlets, execute scheduled events, and enforce start‑up sequences to minimize inrush and maximize device longevity, all without visiting the rack.
  • Networked management and alerts: Web UI plus SNMP integration supports centralized monitoring, dashboards, historical reporting, and configurable alerting to notify teams about threshold breaches and device health issues.
  • Rack‑level design for dense deployments: 1U form factor with 20 outlets designed for easy access and clean cable management in standard 19" racks, ideal for data centers, server rooms, and edge locations seeking scalable power intelligence.
  • Energy analytics for efficiency and cost control: Comprehensive usage data and trend reporting enable accurate capacity planning, cost allocation, and optimization of workload placement to reduce overall energy consumption.

Technical Details of Raritan PX3-5405V 20-Outlets PDU

  • Model: PX3-5405V
  • Outlets: 20
  • Form factor: 1U rack-mountable
  • Metering: real-time monitoring of current, voltage, power (kW/kVA), and energy (kWh) with +/- 1% accuracy
  • Management: integrated network interface with a web UI and SNMP support; supports alerting and remote configuration

How to install Raritan PX3-5405V 20-Outlets PDU

Installing the PX3‑5405V is a straightforward process designed to minimize rack downtime and disruption. Begin by preparing your rack and ensuring you have the appropriate mounting hardware. The PX3‑5405V is designed for standard 19" racks and typically fits in a 1U slot. Use the included mounting rails and screws to secure the PDU firmly in the rack, verifying that there is adequate clearance for cables and airflow around the unit. Proper mounting not only ensures stable operation but also helps maintain optimal cooling conditions for the equipment installed in the same rack.

Next, connect the PDU to its primary power source. Use a suitable power input cable that matches your data center’s electrical infrastructure, and verify that the circuit feeding the PDU has adequate capacity for the combined load of all 20 outlets. After the physical power connection, attach a network cable from the PDU’s Ethernet port to your management network. This step enables remote monitoring, alerting, and control via the built‑in web interface and supports integration with DCIM and other IT management tools through SNMP.

Power up the PX3‑5405V and begin configuring its network settings. You can assign a static IP address or configure DHCP to obtain one automatically, depending on your network design. Once the device is reachable, log in to the web UI and complete the initial setup: assign naming, label each outlet clearly for easy identification, and configure any outlet groups or aliasing that aligns with your rack topology. The next step is to establish thresholds and alerting rules. Define per‑outlet or per‑group limits for current, voltage, and energy consumption, and set up email or SMS notifications to alert your team if any parameter crosses its limit. This proactive approach helps you catch issues before they translate into downtime or equipment stress.

With the PX3‑5405V configured, you can begin leveraging its monitoring dashboards. Create tailored views for operators, facilities personnel, and IT managers so each group sees the most relevant data. Take advantage of the per‑outlet metrics to identify power‑hungry devices, validate whether a particular device is drawing more than expected during startup, and adjust workload placement accordingly. If you are integrating with existing DCIM or monitoring systems, import the PX3‑5405V data via SNMP or standard APIs to centralize power analytics in your broader IT performance dashboards. Regularly reviewing historical data helps you spot trends, evaluate the effectiveness of power‑capping policies, and plan for future rack expansions with confidence.

Finally, establish a maintenance routine to ensure ongoing reliability. Periodically verify labeling accuracy, inspect cable management for any signs of wear, and review alerting policies to adapt to changing workloads. As your IT environment evolves, the PX3‑5405V scales with you, giving you deeper insight into energy use, the ability to automate routine power tasks, and the assurance that critical servers and storage devices stay powered reliably with minimal manual intervention.

Frequently asked questions

  • What is the Raritan PX3-5405V? It is a 20-outlet intelligent rack PDU from Raritan’s PX3 family, offering outlet-level metering, real-time power analytics, and remote control for efficient, centralized power management in data centers and IT rooms.
  • How many outlets does it have? It has 20 outlets, allowing you to distribute power across multiple devices within a single rack and monitor each outlet individually for precise energy use.
  • What metrics does it monitor? It provides real-time readings for current (amps), voltage, power (kW/kVA), and energy (kWh) at the outlet level, with billing‑grade accuracy of +/- 1%.
  • How do I manage and control the PDU? You can manage it via a built‑in web UI and SNMP. This enables remote monitoring, alerting, outlet‑level control, and scheduling of power events without on-site visits.
  • Is it suitable for DCIM integration? Yes. The PX3 series is designed for integration with DCIM platforms through standard interfaces, enabling centralized power visibility across multiple racks and data centers.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like