Raritan PX3-5703V-E2V2 36-Outlets PDU

RaritanSKU: 5730747

Price:
Sale price$3,478.43

Description

Raritan PX3-5703V-E2V2 36-Outlets PDU

The Raritan PX3-5703V-E2V2 is a high-capacity, 36-outlet PDU designed for modern data centers and IT racks. This Switched Outlet Monitored PDU delivers precise, outlet-level visibility and remote control over power distribution, helping you protect critical equipment, optimize energy use, and streamline rack management. Built to support demanding environments, it integrates seamlessly with standard data center workflows and DCIM solutions, enabling proactive monitoring and rapid fault isolation without onsite visits. If you’re looking to simplify power distribution while maintaining strict uptime, the PX3-5703V-E2V2 is engineered to deliver reliable performance, scalable control, and steady operational insight across your entire IT infrastructure.

  • 36 outlets in a single unit provide expansive power distribution for dense racks, consolidating multiple devices into one centralized management point and reducing cable clutter for easier maintenance and improved airflow.
  • Switched Outlet Monitored design offers real-time status for each outlet, empowering operators to identify load imbalances, detect tripped circuits quickly, and perform rapid fault isolation to minimize downtime.
  • 400 V power capability aligns with common data center power architectures, supporting high-density servers and network gear while enabling efficient distribution across three-phase infrastructure where applicable.
  • Network (RJ-45) management enables remote configuration, monitoring, and alerting from anywhere in the data center or via integrated DCIM tools, reducing the need for on-site visits and enabling proactive maintenance.
  • IEC 60320 C13 receptacles with built-in protection ensures compatibility with standard IT equipment and reliable power delivery, while protecting connected devices through integrated circuit protection and controlled outlet operations.

Technical Details of Raritan PX3-5703V-E2V2 36-Outlets PDU

  • Model: PX3-5703V-E2V2
  • Outlet count: 36
  • Input voltage: 400 V
  • Receptacles: IEC 60320 C13
  • Management interface: Network (RJ-45)
  • Power management: Switched, Monitored with per-outlet visibility
  • Mounting: 19-inch rack-mount capable
  • Protection features: Circuit protection for connected outlets
  • Application: Data center and IT rack power distribution

how to install Raritan PX3-5703V-E2V2 36-Outlets PDU

Installing the PX3-5703V-E2V2 begins with preparing your rack and power environment. Locate a suitable 19-inch rack space with adequate clearance for heat dissipation and cable management. Use compatible mounting hardware to secure the PDU firmly, ensuring it is level and stable to prevent vibration or accidental disconnection. Connect the PDU to a 400 V power source appropriate for your data center configuration, following all local electrical codes and safety procedures. Route power and data cables neatly to maintain airflow and simplify future maintenance. Next, connect the PDU’s management interface to your network using the RJ-45 port. This enables remote access to monitoring dashboards and control features. Power up the unit and access the built-in web interface or your preferred DCIM integration to configure outlet-level monitoring, set alert thresholds, and enable remote control of individual outlets. Finally, verify operation by testing select outlets, confirming that switches respond remotely, and that per-outlet load data reports accurately in your management system. Routine checks and updates help ensure ongoing reliability and visibility across your IT environment.

Frequently asked questions

  • What is the PX3-5703V-E2V2? It is a 36-outlet Switched Outlet Monitored PDU designed for power distribution in data centers and IT racks, with remote management capabilities.
  • What voltage does it support? It is designed for 400 V input power, suitable for common data center distribution schemes and three-phase environments.
  • Can I monitor and control outlets remotely? Yes. The PX3-5703V-E2V2 provides network (RJ-45) connectivity that enables outlet-level monitoring and remote switching from your management console or DCIM tools.
  • What receptacles are used? The unit uses IEC 60320 C13 receptacles, ensuring compatibility with standard IT equipment and power cords.
  • How do I install and configure it? Install in a standard 19-inch rack, connect to a 400 V power source, link the RJ-45 management port to your network, and use the PDU’s web interface or your DCIM software to configure outlets, set alerts, and begin monitoring load and performance.