Server Technology Switched PDU - 2.8kW, C1W08HC-1DCA2BA5

Server TechnologySKU: 5388712

Price:
Sale price$1,106.46

Description

Server Technology PRO1 Switched PDU - 2.8kW, C1W08HC-1DCA2BA5

The Server Technology PRO1 Switched PDU delivers precise, per-outlet power control for high-density server racks, enabling IT teams to manage and monitor energy usage with confidence. With a robust 2.8 kW capacity and eight individually switched outlets, this PDU puts power decisions in your hands—helping you balance loads across phases, prevent overloads, and streamline maintenance without sacrificing uptime. The integration of PIPS technology provides billing-grade accuracy, ensuring energy consumption can be tracked, charged, and reported with the level of precision required for modern data centers, managed service providers, and enterprise IT environments. Designed for 19-inch racks in a compact 1U footprint, the PRO1 Switched PDU fits seamlessly into existing infrastructure while delivering advanced monitoring, quick-access status indicators, and reliable fault protection. Whether you’re deploying a new rack, upgrading an older installation, or implementing a centralized energy-management strategy, this PDU supports proactive power management, faster troubleshooting, and lower total cost of ownership through smarter energy use and improved device visibility.

  • Granular power control and load awareness: Across eight outlets, you receive per-outlet switching capabilities plus real-time current monitoring. This enables on-the-fly maintenance, controlled reboots, and the ability to prevent overload conditions before they impact critical servers. Local LED input current monitoring provides at-a-glance visibility of current draw, reducing mean time to identify overloaded circuits. By encouraging balanced loads across phases, this PDU minimizes the risk of tripped breakers and undervoltage conditions, which can compromise performance or cause unplanned downtime. The combination of outlet-level control and live monitoring makes it easier to implement energy-aware deployment strategies and protect assets from power-related failures.

  • Remote management and monitoring for modern data centers: The PRO1 Switched PDU is designed for easy integration into IT governance frameworks. It supports remote control, scheduling, and alerting through an intuitive interface, empowering IT staff to automate routine tasks such as automatic outlet startup sequences, reboots, and shutdowns during maintenance windows. With centralized visibility, you can monitor energy usage across racks, set thresholds for proactive notifications, and correlate power trends with device performance. This capability is particularly valuable in remote offices, colocation environments, and distributed data centers where on-site access is limited but control must remain immediate and reliable.

  • PIPS technology for billing-grade accuracy: The integrated PIPS (Power Indicator and Power Sensing) system provides highly accurate energy measurement and reporting. This means energy consumption data can be used for chargeback or showback programs, budgeting, and sustainability reporting with confidence. PIPS supports precise monitoring of energy usage per outlet and per phase, enabling more sophisticated energy optimization strategies and helping organizations meet internal and external reporting requirements. In practice, you’ll gain clearer insight into which devices or workloads are driving power usage, supporting smarter infrastructure planning and cost control.

  • Rack-ready design with scalable reliability: The PRO1 Switched PDU is built for standard 19-inch racks and occupies a compact 1U height, making it an unobtrusive upgrade for dense server rooms. Front-facing outlets, easy cable management, and sturdy construction simplify installation and maintenance in busy data centers. The modular, replaceable components and robust protections deliver dependable operation in mission-critical environments, while the device’s front-access design ensures quick access for diagnostics, reprogramming, or outlet management without removing equipment from the rack. This combination of physical design and protective features contributes to uptime, ease of service, and long-term reliability in demanding IT environments.

  • Energy efficiency and operational insight: By delivering granular load data and outlet-level control, the PRO1 PDU supports energy-efficiency initiatives and capacity planning. IT teams can identify high-consumption devices, group outlets for coordinated power-down during maintenance windows, and implement policies that reduce peak demand. The result is not only reduced operational costs but also improved thermal management, which can extend hardware life and reduce cooling requirements in data centers. The ability to review historical power trends alongside real-time measurements helps organizations optimize performance, lower electricity spend, and align with sustainability goals.

Technical Details of Server Technology Switched PDU - 2.8kW, C1W08HC-1DCA2BA5

  • Model: C1W08HC-1DCA2BA5
  • Power capacity: 2.8 kW (suitable for typical IT loads at standard data-center voltages; compatible with 208/230V configurations)
  • Outlets: 8 switched receptacles with per-outlet control and status indicators
  • Monitoring: Local LED input current monitoring with PIPS technology for billing-grade energy accuracy
  • Management: Ethernet-based remote management with web UI and SNMP support for alerting, scheduling, and outlet-level control
  • Form factor: 1U rack-mountable, 19-inch standard enclosure designed for front access and straightforward cable management
  • Protection and safety: Built-in overcurrent protection and surge tolerance to safeguard connected equipment

How to install Server Technology Switched PDU

Installing the PRO1 Switched PDU is designed to be straightforward and non-disruptive to existing rack configurations. Start by preparing your rack: ensure there is adequate space for ventilation, access to a suitable power feed, and a clear path for cable routing. Install the mounting rails or brackets provided with the unit into the rack, aligning them with standard 19-inch mounting holes. Carefully slide the PDU into the rack, align the mounting points, and secure it with screws to ensure a stable, vibration-free installation. Connect the main power input to a suitable power source that matches the PDU’s rating, ensuring the feed has the capacity to support the 2.8 kW load. Once physically installed and powered, connect your IT devices to the eight outlets, planning outlet usage to optimize load balance across phases and minimize cable clutter. Power up the PDU and access the management interface via the dedicated network connection. Configure per-outlet switching groups, establish scheduling rules for maintenance windows, and enable alerting for abnormal current draw. Calibrate the PIPS energy monitoring if required by your monitoring system, and verify that all outlets reflect accurate status in the front panel indicators and the management console. Finally, document your configuration for change-management records and communicate the new setup to relevant teams. Routine checks should include verifying outlet status, confirming that switching actions execute as expected, and reviewing energy reports to identify any anomalies or trends requiring action.

Frequently asked questions

  • What is the power rating of this PDU? The PRO1 Switched PDU is rated at 2.8 kW, providing robust capacity for medium-to-high-density IT deployments and enabling safe, per-outlet load management across phases.
  • How many outlets does it offer and can I control them individually? It features eight individually switched outlets, each with its own control and status indication, allowing precise management of devices and workloads connected to the PDU.
  • Can I monitor energy usage and configure alerts? Yes. The PDU integrates PIPS-based energy measurement and supports remote management via web UI and SNMP, including alerting and scheduling to help you respond quickly to changes in power consumption.
  • Is the PDU compatible with standard racks? The unit is designed for standard 19-inch racks and occupies 1U of rack height, making it a plug-in upgrade for existing rack infrastructure without requiring major reconfiguration.
  • What benefits does PIPS bring? PIPS provides billing-grade accuracy for energy usage, enabling precise chargeback, budgeting, and sustainability reporting, while delivering per-outlet and per-phase visibility that supports smarter capacity planning and energy optimization.