Description
Supermicro 2U SCA Backplane
The Supermicro 2U SCA Backplane is engineered for high-density storage in enterprise-grade servers. Designed to fit standard 2U chassis, this backplane delivers robust drive connectivity, streamlined cable routing, and reliable hot-swappable operation for data centers, HPC environments, and growing storage arrays. By consolidating SAS/SATA drive interfaces into a single, reusable backplane, it reduces maintenance time, simplifies upgrades, and helps IT teams maximize uptime. Built to align with Supermicro’s trusted hardware ecosystem, this backplane emphasizes durability, consistent signal integrity, and efficient airflow management to keep systems cool under heavy I/O workloads. Whether you’re expanding capacity or replacing an aging backplane, this solution offers a dependable path to scalable, enterprise-ready storage performance.
- Efficient 2U form factor for dense server configurations. This backplane is purpose-built to fit within 2U server chassis, enabling you to maximize rack space without compromising drive density. By consolidating drive interfaces into a single mid-plane solution, it simplifies internal wiring and reduces cable clutter, improving airflow and ease of service. The 2U footprint is ideal for scale-out storage nodes, data center clusters, and hyper-converged deployments where every rack unit matters. You gain a cleaner internal layout, easier component access, and smoother upgrades as your storage demands evolve, all while maintaining compatibility with a broad range of Supermicro systems.
- SCA connectivity for SAS/SATA drives. The backplane leverages the Single Connector Attachment (SCA) standard to deliver reliable SAS/SATA drive connectivity with minimal cabling. This approach improves signal integrity and reduces the risk of misconnected cables during maintenance. By supporting a wide variety of SAS and SATA drives through a single, standardized interface, it enables flexible drive selection and future-proofing for firmware updates and expanding capacities. For data-intensive workloads—such as databases, virtualization, and media workflows—SCA backplanes help sustain steady throughput and low-latency access with consistent performance across drive migrations.
- Hot-swappable drive bays and streamlined maintenance. With hot-swappable capabilities, this backplane supports rapid drive replacement without powering down the system, maximizing uptime in production environments. IT teams can swap failed or upgrading drives during maintenance windows, accelerating rebuilds and reducing downtime. The design emphasizes secure drive latch mechanisms, reliable connector engagement, and straightforward drive tray installation to minimize operator error. In environments that demand high availability, this backplane delivers the practical efficiency needed to keep critical workloads online with minimal disruption.
- Rigid design and optimized airflow for sustained performance. The Supermicro 2U SCA Backplane is built with rugged materials and precise tolerances to ensure durable operation in demanding data centers. Its solid chassis integration minimizes vibration and thermal noise, while engineering considerations for airflow help maintain stable temperatures under heavy I/O. Efficient cooling translates into longer drive life, more predictable performance, and reduced risk of thermal throttling during peak workloads. Administrators benefit from consistent thermal profiles and lower risk of overheating components in dense 2U configurations.
- Compatibility across Supermicro ecosystems and easy integration. This backplane is designed to work seamlessly with Supermicro motherboards, backplanes, and chassis, providing reliable interoperability within a familiar hardware ecosystem. Compatibility reduces integration complexity, accelerates deployment timelines, and simplifies firmware and BIOS configuration. Whether you’re building a new storage array or upgrading an existing setup, you can expect smooth integration, clear documentation, and support for common enterprise storage paradigms such as RAID, hot-spare configurations, and drive-pool expansions.
Technical Details of Supermicro 2U SCA Backplane
Technical specifications are provided by the vendor and may vary by SKU. The following details summarize typical capabilities and considerations for this backplane within a standard 2U chassis. Always refer to the exact SKU documentation for precise values, compatibility lists, and required cabling.
- Form factor: 2U backplane designed to fit 2U server chassis and align with standard mid-plane mounting patterns to ensure a secure, stable installation.
- Interface: SCA-based drive connectivity for SAS and SATA drives, reducing cable complexity and supporting reliable signal integrity in dense deployments.
- Drive support: Compatible with SAS and SATA drives via the SCA backplane interface; supports hot-swappable drive trays (subject to chassis compatibility) to enable rapid maintenance and minimal downtime.
- Connectivity and integration: Designed to integrate with Supermicro server ecosystems, with attention to consistent power rails, airflow considerations, and BIOS/firmware coordination for drive recognition and hot-swap behavior.
- Cooling and reliability: Built to promote effective airflow within 2U systems, reducing thermal hotspots and enhancing drive longevity for sustained performance under load.
How to install Supermicro 2U SCA Backplane
- Power down the server, unplug from the electrical outlet, and discharge any static build-up before handling components. Ground yourself and remove the server chassis access panels to expose the internal area where the backplane will be installed.
- If replacing an existing backplane, carefully disconnect all drive cables and any chassis interconnects, noting the routing of cables to ensure a clean reassembly. Remove the old backplane mounting screws and set them aside for reuse with the new unit.
- Position the Supermicro 2U SCA Backplane so that its mounting holes align with the chassis rails. Gently slide the backplane into the chassis until it sits flush against the mid-plane connectors and mounting points. Make sure there are no bent pins and that the backplane is seated squarely to avoid misalignment during operation.
- Secure the backplane with the appropriate screws, then connect the SCA backplane cables to the server’s interconnects or mid-plane as specified by the chassis documentation. Ensure all connectors are fully seated and that the cabling does not impede airflow or drive trays from closing properly.
- Install the drive trays into the backplane, verifying that each tray latches securely and that the drives are properly seated. Reinstall side panels, reseal the chassis, and reconnect power. Power on the system and enter the BIOS/RAID controller configuration to confirm drive visibility and correct hot-swap behavior. Run a quick hardware diagnostic to verify drive recognition and baseline performance before placing the system back into production.
Frequently asked questions
- Q: What is a 2U SCA Backplane used for? A: It provides centralized drive connectivity in a 2U server chassis using the SCA interface for SAS/SATA drives. This backplane enables hot-swappable drive bays, simplifies maintenance, and supports scalable storage configurations in data centers and enterprise environments.
- Q: Which drives are compatible? A: The backplane supports SAS and SATA drives that are compatible with SCA-based backplanes. Always verify drive compatibility with your specific chassis and mid-plane to ensure proper fit and performance.
- Q: Is the backplane hot-swappable? A: Yes, the design supports hot-swappable drives in compatible chassis configurations, enabling drive replacement without powering down the server, which minimizes downtime during maintenance and upgrades.
- Q: Do I need additional cables or adapters? A: Depending on your chassis and motherboard, you may require specific interconnect cables or adapters as recommended by Supermicro. Always follow the chassis documentation for correct cabling to preserve signal integrity and support hot-swap functionality.
- Q: How do I know if this backplane fits my server? A: Check your server model, chassis form factor (2U), and any mid-plane compatibility notes in the chassis and backplane documentation. If you’re unsure, consult the vendor catalog or support resources for SKU-specific compatibility.
Customer reviews
Showing - Of Reviews