Tripp Lite by Eaton 20-30kVA 3-Phase Power Distribution Center 3 Breaker 208V Service Service Bypass Switch

Tripp Lite by EatonSKU: 2970090

Price:
Sale price$8,804.71

Description

Tripp Lite by Eaton 20-30kVA 3-Phase Power Distribution Center with 3-Breaker 208V Service Bypass Switch

The Tripp Lite by Eaton SUDC208V42P30M Power Distribution Cabinet is purpose-built for mission-critical data centers and enterprise IT environments that demand uninterrupted power and effortless maintenance. Engineered to support 20-30kVA three-phase UPS power distribution in server racks, this cabinet combines rugged reliability with a streamlined maintenance workflow. Its integrated 3-breaker 208V service bypass switch is a defining feature, enabling hot-swappable replacement of UPS units without dropping connected critical loads. In other words, you can perform UPS swaps and servicing while your IT infrastructure keeps running, preserving uptime and safeguarding your business operations.

  • Power distribution for 20-30kVA 3-phase UPS systems in a single, purpose-built cabinet designed for racks and data-center deployments. It consolidates distribution, bypass, and UPS integration in a compact footprint, helping to optimize floor space and simplify cabling.
  • Integrated 3-breaker 208V service bypass switch that isolates the UPS from critical loads for maintenance or replacement. This feature makes hot-swappable UPS upgrades feasible without interrupting power to racks, dramatically reducing planned downtime and enabling smoother IT operations.
  • Designed for reliable operation in data centers and high-density IT environments. The enclosure and wiring architecture prioritize safety, accessibility, and serviceability, with front-access design considerations that speed installation, inspections, and routine maintenance.
  • Optimized for 208V data center infrastructure, delivering clean, stable power with minimal impedance to connected equipment. The cabinet is built to support modern three-phase UPS configurations, helping you future-proof as your load grows or changes.
  • Rugged construction and streamlined installation workflows are complemented by clear labeling, modular components, and compatibility with standard rack environments. This cabinet is intended to integrate seamlessly with Tripp Lite/Eaton UPS systems to deliver consistent power reliability across critical workloads.

Technical Details of Tripp Lite by Eaton 20-30kVA 3-Phase Power Distribution Center

  • Power rating: 20-30 kVA, three-phase UPS power distribution for critical data-center equipment
  • Service bypass: integrated 3-breaker 208V bypass switch for safe maintenance and hot-swappable UPS replacement
  • Input/ Output configuration: 208V three-phase service designed to support standard data-center UPS systems
  • Enclosure and construction: rugged cabinet designed for rack mounting in data-center environments with front-access maintenance
  • Compatibility: optimized for Tripp Lite/Eaton UPS solutions and compatible with modern 20-30kVA three-phase power architectures
  • Maintenance capability: hot-swappable UPS integration with bypass to maintain continuous loads during service or UPS upgrade
  • Safety and compliance: built with attention to electrical safety, labeling, and serviceability for data-center standards

how to install Tripp Lite by Eaton 20-30kVA 3-Phase Power Distribution Center

Installing the SUDC208V42P30M Power Distribution Cabinet involves careful planning, adherence to safety protocols, and collaboration with your facilities team. Begin by reviewing the UPS compatibility and installation manual to ensure you are aligning with the specific model’s connection points and clearance requirements. Plan the rack layout to accommodate the cabinet’s footprint, cable routes, and service clearances for the bypass switch and access panels. The goal is to minimize disruption during installation while ensuring easy future maintenance and upgrades.

Step-by-step guidance for a typical deployment includes the following:

1) Prepare the installation site: Confirm the rack space, floor load capacity, and ambient conditions meet the cabinet’s requirements. Ensure power distribution pathways, cable trays, and room cooling are rated for the anticipated load. Verify that the UPS and battery modules you plan to use are compatible with the 3-phase 208V distribution cabinet and that all electrical codes and safety protocols are observed.

2) Mount the cabinet: Secure the power distribution cabinet in the chosen rack location. Use the appropriate mounting hardware for your rack system and ensure the cabinet is level and stable. The front-access design should allow tools-free or minimal tooling access for routine service and inspection.

3) Route and connect power cables: Connect the cabinet input to the UPS system using the manufacturer-recommended conductors and connectors. Route input and output cables cleanly, label them for maintenance, and maintain separation from data cables to reduce interference. Verify that the 208V three-phase connections align with the UPS output and the intended distribution to IT loads.

4) Configure the bypass switch and breakers: Install and configure the integrated 3-breaker 208V service bypass switch per the installation manual. Ensure the bypass is wired correctly to provide a safe, isolated path for UPS maintenance. Test the bypass operation with the UPS in a controlled scenario to confirm it can bypass loads without impacting connected equipment.

5) Commissioning and testing: With electrical connections secure, perform a controlled startup procedure. Validate all protective devices, wiring terminations, and labeling. Use metering equipment to confirm voltage, phase balance, and cleanliness of the power delivered to IT equipment. Document the test results and verify that UPS monitoring instrumentation recognizes the distribution cabinet and bypass configuration.

6) Final checks and documentation: Confirm fault indicators, status LEDs, and alarm outputs function as intended. Ensure spare parts and a maintenance plan are in place. Maintain up-to-date documentation for future service personnel, including wiring diagrams, breaker labeling, and bypass switch procedures. A well-documented installation reduces troubleshooting time and supports safer, more efficient maintenance.

Note: This installation guide provides a high-level overview. Always follow the manufacturer’s official installation manual and your organization’s electrical safety protocols. If you are unsure about any step, consult a licensed electrical professional to ensure safe and compliant installation.

Frequently asked questions

  • What is the purpose of the 208V service bypass switch on this cabinet?
  • The integrated 3-breaker 208V service bypass switch allows you to bypass the UPS and temporarily power loads directly from the bypass path during maintenance or UPS replacement. This capability enables hot-swappable UPS changes without interrupting critical loads, reducing downtime and preserving uptime for essential IT infrastructure.

  • Can this cabinet support hot-swapping a 20-30kVA UPS without downtime?
  • Yes. The design centers on a service bypass that isolates the UPS from the critical loads, enabling maintenance or replacement while the loads remain powered. Properly executed, the bypass switch allows you to perform UPS swaps with minimal or no disruption to connected equipment.

  • Is the cabinet limited to Tripp Lite UPS systems, or is it compatible with other brands?
  • The cabinet is designed to support 20-30kVA three-phase UPS configurations and 208V infrastructure, and while it is optimized for Tripp Lite/Eaton UPS solutions, it can be compatible with other brands that adhere to similar electrical interfaces and standards. Always verify compatibility with the UPS manufacturer and your facilities team before committing to a deployment.

  • What advantages does a 3-phase, 208V distribution cabinet offer for data centers?
  • Three-phase distribution improves power efficiency, reduces conductor sizes for the same power, and provides better load balancing across phases. The 208V system is common in data centers, offering a practical voltage level for delivering high-density power to servers and storage equipment while maintaining manageable cable complexity and cooling demands.

  • What maintenance considerations should I plan for with this cabinet?
  • Plan routine inspections of cables, connectors, and breaker terminations. Confirm that bypass switch operation is tested periodically, and ensure the UPS monitoring and alerting systems are in sync with the cabinet. Maintain a current spare parts inventory and provide clear documentation for service teams, including wiring diagrams and bypass procedures. Regular checks help prevent unexpected outages and support long-term reliability.