Tripp Lite by Eaton 2U UPS Replacement 48VDC Battery Cartridge (2 Sets of 4) for Select UPS systems

Tripp Lite by EatonSKU: 3016126

Price:
Sale price$643.27

Description

Tripp Lite by Eaton 2U UPS Replacement 48VDC Battery Cartridge (2 Sets of 4) for Select UPS systems

Protect your critical equipment with the Tripp Lite by Eaton 2U UPS Replacement 48VDC Battery Cartridge. This premium replacement battery solution is designed to revive and extend the life of compatible Uninterruptible Power Supplies (UPS), ensuring reliable backup power when you need it most. With two complete sets of four 48VDC battery modules, this cartridge pack simplifies maintenance, reduces downtime, and helps you preserve uptime for servers, networking gear, and other essential devices in data centers, offices, and remote sites. Built to meet the demanding standards of data protection, these cartridges deliver stable voltage, robust construction, and dependable performance across a range of operating conditions. Whether you’re performing routine maintenance, refreshing aging batteries, or upgrading a legacy UPS, this 48VDC cartridge set provides a practical, cost-effective path to improved reliability and resilience.

  • High‑quality 48VDC replacement battery cartridge: Engineered to deliver consistent backup power for compatible UPS systems, helping you maintain critical load protection during outages or voltage drops.
  • 2 sets of 4 battery modules: Each purchase includes two complete packs of four modules, enabling faster replacement and streamlined inventory management for multi‑bay or high‑demand installations.
  • 2U rack‑mount form factor: Designed to fit into standard 2U chassis spaces, making integration with compatible UPS equipment straightforward and space‑efficient in crowded data closets or telecom racks.
  • Compatibility with select UPS systems: Precisely engineered to work with Tripp Lite by Eaton UPS models and other compatible systems that use 48VDC battery cartridges, ensuring a reliable match for your backup infrastructure.
  • Factory‑tested reliability and safety: Each cartridge undergoes rigorous manufacturing and quality control processes to verify voltage, capacity, and safety standards before shipment, giving you confidence in performance and longevity.

Technical Details of Tripp Lite by Eaton 2U UPS Replacement 48VDC Battery Cartridge (2 Sets of 4) for Select UPS systems

  • Voltage: 48VDC
  • Battery configuration: 2 sets of 4 battery modules
  • Form factor: 2U rack-mount cartridge
  • Compatibility: for select UPS systems that use 48VDC replacement batteries (Tripp Lite by Eaton models and other compatible units; verify model compatibility with your UPS documentation)
  • Condition: new, factory‑sealed replacement parts

How to install Tripp Lite by Eaton 2U UPS Replacement 48VDC Battery Cartridge

  • Power down the UPS and disconnect it from all loads and the mains supply before beginning the replacement process, following your facility’s electrical safety procedures.
  • Open the UPS access panel or cabinet according to the manufacturer’s instructions, ensuring you have a static-safe work area and proper grounding.
  • Locate the battery compartment and identify the existing 48VDC cartridge assembly. If applicable, remove any securing hardware or covers that hold the cartridge in place.
  • Carefully detach the old cartridge(s) by disconnecting any quick‑connectors or interlocks, handling modules by their edges to avoid pressure on the cells and wiring.
  • Align the new cartridge’s connectors with the UPS interface and slide the two sets of four modules into the designated slot(s) until seated firmly. Reattach any mounting hardware or latches as required by your UPS model.
  • Close the access panel, re‑connect the UPS to power, and perform a self-test or guided battery test via the UPS management interface to confirm proper operation and charging. If the UPS supports a battery health check, run it to verify capacity and voltage within expected ranges.

Frequently asked questions

  • Q: What exactly is included in the package?
  • A: The package includes two complete sets of four 48VDC battery modules, designed to replace existing cartridges in compatible UPS systems. This enables a straightforward, two‑step replacement in many configurations and ensures you have sufficient modules to refresh older units efficiently.

  • Q: Which UPS models are compatible with this cartridge?
  • A: This replacement battery cartridge is intended for select UPS systems that use a 48VDC cartridge format from Tripp Lite by Eaton and other compatible models. Always verify model compatibility with your UPS manufacturer’s documentation or product support to ensure a proper fit and safe operation.

  • Q: How does runtime vary after installation?
  • A: Runtime depends on the UPS’s load, battery health, and operating conditions. Replacing aging 48VDC batteries with fresh modules can restore longer backup times for critical workloads, but exact runtime should be tested under your typical load during a planned maintenance window.

  • Q: Are there safety precautions I should follow?
  • A: Yes. Always power down and unplug the UPS before maintenance, work in a static‑safe environment, and follow all local electrical codes. Use proper PPE if required and handle battery modules carefully to avoid damage or injury. If you are unsure about installation, consult a qualified technician.

  • Q: How should I dispose of old battery cartridges?
  • A: Follow your local regulations for battery disposal and recycling. Many regions offer hazardous‑waste collection programs or electronics recycling centers that accept UPS batteries. Recycle to minimize environmental impact and comply with safety guidelines.